Matthew R. Ochs
2843fdbddd cxlflash: Fix data corruption when vLUN used over multiple cards
If the same virtual LUN is accessed over multiple cards, only accesses
made over the first card will be valid. Accesses made over the second
card will go to the wrong LUN causing data corruption.

This is because the global LUN's mode word was being used to determine
whether the LUN table for that card needs to be programmed. The mode
word would be setup by the first card, causing the LUN table for the
second card to not be programmed.

By unconditionally initializing the LUN table (not depending on the
mode word), the problem is avoided.

Signed-off-by: Matthew R. Ochs <mrochs@linux.vnet.ibm.com>
Signed-off-by: Manoj N. Kumar <manoj@linux.vnet.ibm.com>
Reviewed-by: Brian King <brking@linux.vnet.ibm.com>
Reviewed-by: Tomas Henzl <thenzl@redhat.com>
Signed-off-by: James Bottomley <JBottomley@Odin.com>
2015-10-30 17:01:07 +09:00
Matthew R. Ochs
22fe1ae80f cxlflash: Fix potential oops following LUN removal
When a LUN is removed, the sdev that is associated with the LUN
remains intact until its reference count drops to 0. In order
to prevent an sdev from being removed while a context is still
associated with it, obtain an additional reference per-context
for each LUN attached to the context.

This resolves a potential Oops in the release handler when a
dealing with a LUN that has already been removed.

Signed-off-by: Matthew R. Ochs <mrochs@linux.vnet.ibm.com>
Signed-off-by: Manoj N. Kumar <manoj@linux.vnet.ibm.com>
Reviewed-by: Brian King <brking@linux.vnet.ibm.com>
Reviewed-by: Tomas Henzl <thenzl@redhat.com>
Signed-off-by: James Bottomley <JBottomley@Odin.com>
2015-10-30 17:00:52 +09:00
Manoj Kumar
471a5a60aa cxlflash: Fix read capacity timeout
The timeout value for read capacity is too small. Certain devices
may take longer to respond and thus the command may prematurely
timeout. Additionally the literal used for the timeout is stale.

Update the timeout to 30 seconds (matches the value used in sd.c)
and rework the timeout literal to a more appropriate description.

Signed-off-by: Matthew R. Ochs <mrochs@linux.vnet.ibm.com>
Signed-off-by: Manoj N. Kumar <manoj@linux.vnet.ibm.com>
Reviewed-by: Brian King <brking@linux.vnet.ibm.com>
Reviewed-by: Tomas Henzl <thenzl@redhat.com>
Signed-off-by: James Bottomley <JBottomley@Odin.com>
2015-10-30 16:58:09 +09:00
Manoj Kumar
3ebf203093 cxlflash: Replace magic numbers with literals
Magic numbers are not meaningful and can create confusion. As a
remedy, replace them with descriptive literals.

Replace 512 with literal MAX_SECTOR_UNIT.
Replace 5 with literal CMD_RETRIES.

Signed-off-by: Matthew R. Ochs <mrochs@linux.vnet.ibm.com>
Signed-off-by: Manoj N. Kumar <manoj@linux.vnet.ibm.com>
Reviewed-by: Brian King <brking@linux.vnet.ibm.com>
Reviewed-by: Andrew Donnellan <andrew.donnellan@au1.ibm.com>
Reviewed-by: Tomas Henzl <thenzl@redhat.com>
Signed-off-by: James Bottomley <JBottomley@Odin.com>
2015-10-30 16:57:55 +09:00
Manoj Kumar
fa4aa632da cxlflash: Fix to avoid invalid port_sel value
If two concurrent MANAGE_LUN ioctls are issued with the same
WWID parameter, it would result in an incorrect value of port_sel.

This is because port_sel is modified without any locks being
held. If the first caller stalls after the return from
find_and_create_lun(), the value of port_sel will be set
incorrectly to indicate a single port, though in this case
it should have been set to both ports.

To fix, use the global mutex to serialize the lookup of the
WWID and the subsequent modification of port_sel.

Signed-off-by: Matthew R. Ochs <mrochs@linux.vnet.ibm.com>
Signed-off-by: Manoj N. Kumar <manoj@linux.vnet.ibm.com>
Reviewed-by: Brian King <brking@linux.vnet.ibm.com>
Reviewed-by: Tomas Henzl <thenzl@redhat.com>
Signed-off-by: James Bottomley <JBottomley@Odin.com>
2015-10-30 16:57:21 +09:00
Matthew R. Ochs
89576205de cxlflash: Remove unused variable from queuecommand
The queuecommand routine has a local dev pointer used for the
dev_* prints. The two prints that currently exist are tucked
under a debug define and thus can be left out. Use the actual
location instead of a local to avoid this warning.

This patch is intended to be applied after the "CXL Flash Error
Recovery and Superpipe" series.

Signed-off-by: Matthew R. Ochs <mrochs@linux.vnet.ibm.com>
Signed-off-by: Manoj N. Kumar <manoj@linux.vnet.ibm.com>
Reported-by: kbuild test robot <fengguang.wu@intel.com>
Signed-off-by: James Bottomley <JBottomley@Odin.com>
2015-08-26 18:08:47 -07:00
Dan Carpenter
4da74db0d9 cxlflash: shift wrapping bug in afu_link_reset()
"port_sel" is a u64 so the shifting should also be a 64 bit shift.

Fixes: c21e0bbfc4 ('cxlflash: Base support for IBM CXL Flash Adapter')
Signed-off-by: Dan Carpenter <dan.carpenter@oracle.com>
Reviewed-by: Johannes Thumshirn <jthumshirn@suse.de>
Acked-by: Matthew R. Ochs <mrochs@linux.vnet.ibm.com>
Signed-off-by: James Bottomley <JBottomley@Odin.com>
2015-08-26 18:07:37 -07:00
Dan Carpenter
46c6d45d78 cxlflash: off by one bug in cxlflash_show_port_status()
The > should be >= or we read one element past the end of the array.

Fixes: c21e0bbfc4 ('cxlflash: Base support for IBM CXL Flash Adapter')
Signed-off-by: Dan Carpenter <dan.carpenter@oracle.com>
Acked-by: Matthew R. Ochs <mrochs@linux.vnet.ibm.com>
Signed-off-by: James Bottomley <JBottomley@Odin.com>
2015-08-26 18:06:31 -07:00
Matthew R. Ochs
2cb79266d6 cxlflash: Virtual LUN support
Add support for physical LUN segmentation (virtual LUNs) to device
driver supporting the IBM CXL Flash adapter. This patch allows user
space applications to virtually segment a physical LUN into N virtual
LUNs, taking advantage of the translation features provided by this
adapter.

Signed-off-by: Matthew R. Ochs <mrochs@linux.vnet.ibm.com>
Signed-off-by: Manoj N. Kumar <manoj@linux.vnet.ibm.com>
Reviewed-by: Michael Neuling <mikey@neuling.org>
Reviewed-by: Wen Xiong <wenxiong@linux.vnet.ibm.com>
Signed-off-by: James Bottomley <JBottomley@Odin.com>
2015-08-26 18:05:39 -07:00
Matthew R. Ochs
65be2c79ac cxlflash: Superpipe support
Add superpipe supporting infrastructure to device driver for the IBM CXL
Flash adapter. This patch allows userspace applications to take advantage
of the accelerated I/O features that this adapter provides and bypass the
traditional filesystem stack.

Signed-off-by: Matthew R. Ochs <mrochs@linux.vnet.ibm.com>
Signed-off-by: Manoj N. Kumar <manoj@linux.vnet.ibm.com>
Reviewed-by: Michael Neuling <mikey@neuling.org>
Reviewed-by: Wen Xiong <wenxiong@linux.vnet.ibm.com>
Reviewed-by: Brian King <brking@linux.vnet.ibm.com>
Signed-off-by: James Bottomley <JBottomley@Odin.com>
2015-08-26 18:04:37 -07:00
Matthew R. Ochs
5cdac81a87 cxlflash: Base error recovery support
Introduce support for enhanced I/O error handling.

A device state is added to track 3 possible states of the device:

Normal - the device is operating normally and is fully operational

Limbo - the device is in a reset/recovery scenario and its operational
        status is paused

Failed/terminating - the device has either failed to be reset/recovered
                     or is being terminated (removed); it is no longer
                     operational

All operations are allowed when the device is operating normally. When the
device transitions to limbo state, I/O must be paused. To help accomplish
this, a wait queue is introduced where existing and new threads can wait
until the device is no longer in limbo. When coming out of limbo, threads
need to check the state and error out gracefully when encountering the
failed state. When the device transitions to the failed/terminating state,
normal operations are no longer allowed. Only specially designated
operations related to graceful cleanup are permitted.

Signed-off-by: Matthew R. Ochs <mrochs@linux.vnet.ibm.com>
Signed-off-by: Manoj N. Kumar <manoj@linux.vnet.ibm.com>
Reviewed-by: Daniel Axtens <dja@axtens.net>
Reviewed-by: Michael Neuling <mikey@neuling.org>
Reviewed-by: Wen Xiong <wenxiong@linux.vnet.ibm.com>
Reviewed-by: Brian King <brking@linux.vnet.ibm.com>
Signed-off-by: James Bottomley <JBottomley@Odin.com>
2015-08-26 18:03:47 -07:00
Matthew R. Ochs
c21e0bbfc4 cxlflash: Base support for IBM CXL Flash Adapter
SCSI device driver to support filesystem access on the IBM CXL Flash adapter.

Supported-by: Stephen Bates <stephen.bates@pmcs.com>
Reviewed-by: Michael Neuling <mikey@neuling.org>
Signed-off-by: Matthew R. Ochs <mrochs@linux.vnet.ibm.com>
Signed-off-by: Manoj N. Kumar <manoj@linux.vnet.ibm.com>
Reviewed-by: Brian King <brking@linux.vnet.ibm.com>
Signed-off-by: James Bottomley <JBottomley@Odin.com>
2015-07-30 21:02:01 -07:00