spi: kirkwood_spi: implement workaround for FE-9144572

Erratum NO. FE-9144572: The device SPI interface supports frequencies of
up to 50 MHz.  However, due to this erratum, when the device core clock
is 250 MHz and the SPI interfaces is configured for 50MHz SPI clock and
CPOL=CPHA=1 there might occur data corruption on reads from the SPI
device.

Implement the workaround by setting the TMISO_SAMPLE value to 0x2
in the timing1 register.

Signed-off-by: Chris Packham <judge.packham@gmail.com>
Reviewed-by: Stefan Roese <sr@denx.de>
Reviewed-by: Jagan Teki <jagan@openedev.com>
This commit is contained in:
Chris Packham 2018-01-22 22:44:20 +13:00 committed by Jagan Teki
parent 36890ff0d0
commit df16881cea
2 changed files with 72 additions and 3 deletions

View File

@ -57,6 +57,12 @@ struct kwspi_registers {
#define KWSPI_TXLSBF (1 << 13)
#define KWSPI_RXLSBF (1 << 14)
/* Timing Parameters 1 Register */
#define KW_SPI_TMISO_SAMPLE_OFFSET 6
#define KW_SPI_TMISO_SAMPLE_MASK (0x3 << KW_SPI_TMISO_SAMPLE_OFFSET)
#define KW_SPI_TMISO_SAMPLE_1 (1 << KW_SPI_TMISO_SAMPLE_OFFSET)
#define KW_SPI_TMISO_SAMPLE_2 (2 << KW_SPI_TMISO_SAMPLE_OFFSET)
#define KWSPI_IRQUNMASK 1 /* unmask SPI interrupt */
#define KWSPI_IRQMASK 0 /* mask SPI interrupt */
#define KWSPI_SMEMRDIRQ 1 /* SerMem data xfer ready irq */

View File

@ -243,6 +243,10 @@ int spi_xfer(struct spi_slave *slave, unsigned int bitlen,
/* Here now the DM part */
struct mvebu_spi_dev {
bool is_errata_50mhz_ac;
};
struct mvebu_spi_platdata {
struct kwspi_registers *spireg;
};
@ -269,10 +273,44 @@ static int mvebu_spi_set_speed(struct udevice *bus, uint hz)
return 0;
}
static void mvebu_spi_50mhz_ac_timing_erratum(struct udevice *bus, uint mode)
{
struct mvebu_spi_platdata *plat = dev_get_platdata(bus);
struct kwspi_registers *reg = plat->spireg;
u32 data;
/*
* Erratum description: (Erratum NO. FE-9144572) The device
* SPI interface supports frequencies of up to 50 MHz.
* However, due to this erratum, when the device core clock is
* 250 MHz and the SPI interfaces is configured for 50MHz SPI
* clock and CPOL=CPHA=1 there might occur data corruption on
* reads from the SPI device.
* Erratum Workaround:
* Work in one of the following configurations:
* 1. Set CPOL=CPHA=0 in "SPI Interface Configuration
* Register".
* 2. Set TMISO_SAMPLE value to 0x2 in "SPI Timing Parameters 1
* Register" before setting the interface.
*/
data = readl(&reg->timing1);
data &= ~KW_SPI_TMISO_SAMPLE_MASK;
if (CONFIG_SYS_TCLK == 250000000 &&
mode & SPI_CPOL &&
mode & SPI_CPHA)
data |= KW_SPI_TMISO_SAMPLE_2;
else
data |= KW_SPI_TMISO_SAMPLE_1;
writel(data, &reg->timing1);
}
static int mvebu_spi_set_mode(struct udevice *bus, uint mode)
{
struct mvebu_spi_platdata *plat = dev_get_platdata(bus);
struct kwspi_registers *reg = plat->spireg;
const struct mvebu_spi_dev *drvdata;
u32 data = readl(&reg->cfg);
data &= ~(KWSPI_CPHA | KWSPI_CPOL | KWSPI_RXLSBF | KWSPI_TXLSBF);
@ -286,6 +324,10 @@ static int mvebu_spi_set_mode(struct udevice *bus, uint mode)
writel(data, &reg->cfg);
drvdata = (struct mvebu_spi_dev *)dev_get_driver_data(bus);
if (drvdata->is_errata_50mhz_ac)
mvebu_spi_50mhz_ac_timing_erratum(bus, mode);
return 0;
}
@ -343,10 +385,31 @@ static const struct dm_spi_ops mvebu_spi_ops = {
*/
};
static const struct mvebu_spi_dev armada_xp_spi_dev_data = {
.is_errata_50mhz_ac = false,
};
static const struct mvebu_spi_dev armada_375_spi_dev_data = {
.is_errata_50mhz_ac = false,
};
static const struct mvebu_spi_dev armada_380_spi_dev_data = {
.is_errata_50mhz_ac = true,
};
static const struct udevice_id mvebu_spi_ids[] = {
{ .compatible = "marvell,armada-375-spi" },
{ .compatible = "marvell,armada-380-spi" },
{ .compatible = "marvell,armada-xp-spi" },
{
.compatible = "marvell,armada-375-spi",
.data = (ulong)&armada_375_spi_dev_data
},
{
.compatible = "marvell,armada-380-spi",
.data = (ulong)&armada_380_spi_dev_data
},
{
.compatible = "marvell,armada-xp-spi",
.data = (ulong)&armada_xp_spi_dev_data
},
{ }
};