arm:samsung:trats:fix: Restore proper orientation of TRATS's LCD panel
Before setting: mipi_lcd_device.reverse_panel = 1, the Trats's LCD panel
was flipped by 180 degrees.
The flip was caused by following change:
Exynos: Change get_timer() to work correctly
SHA1: 3d00c0cb96
This commit fixed udelay(), which is necessary (due to HW LCD controller
oddity) for mipi-dsi correct operation. As a result the display orientation
has been switched.
As a follow up, the hwrevision() function has been removed, since it was
used only in this particular place.
Test HW: Trats Exynos4210 rev 0.
Signed-off-by: Lukasz Majewski <l.majewski@samsung.com>
Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com>
Cc: Minkyu Kang <mk7.kang@samsung.com>
Acked-by: Minkyu Kang <mk7.kang@samsung.com>
This commit is contained in:
parent
f4eaf88e6d
commit
baa8841d6c
@ -58,12 +58,6 @@ u32 get_board_rev(void)
|
||||
#endif
|
||||
|
||||
static void check_hw_revision(void);
|
||||
|
||||
static int hwrevision(int rev)
|
||||
{
|
||||
return (board_rev & 0xf) == rev;
|
||||
}
|
||||
|
||||
struct s3c_plat_otg_data s5pc210_otg_data;
|
||||
|
||||
int board_init(void)
|
||||
@ -773,9 +767,7 @@ void init_panel_info(vidinfo_t *vid)
|
||||
#ifdef CONFIG_TIZEN
|
||||
get_tizen_logo_info(vid);
|
||||
#endif
|
||||
|
||||
if (hwrevision(2))
|
||||
mipi_lcd_device.reverse_panel = 1;
|
||||
mipi_lcd_device.reverse_panel = 1;
|
||||
|
||||
strcpy(s6e8ax0_platform_data.lcd_panel_name, mipi_lcd_device.name);
|
||||
s6e8ax0_platform_data.lcd_power = lcd_power;
|
||||
|