rockchip: dts: correct vdd_log setting for firefly-rk3399
Add regulator-init-microvolt for driver to init the regulator, and the min output value is not 800000mV for the PWM2 io domain has changed to VCC3V0 instead of VCC1V8 in rockchip evb, we need to correct it with the value measured when PWM2 output HIGH. Signed-off-by: Kever Yang <kever.yang@rock-chips.com> Acked-by: Philipp Tomsich <philipp.tomsich@theobroma-systems.com> Reviewed-by: Philipp Tomsich <philipp.tomsich@theobroma-systems.com>
This commit is contained in:
parent
56f2dd0aed
commit
7ba3182e2d
@ -157,8 +157,9 @@
|
||||
regulator-name = "vdd_log";
|
||||
regulator-always-on;
|
||||
regulator-boot-on;
|
||||
regulator-min-microvolt = <800000>;
|
||||
regulator-min-microvolt = <430000>;
|
||||
regulator-max-microvolt = <1400000>;
|
||||
regulator-init-microvolt = <950000>;
|
||||
};
|
||||
|
||||
vccadc_ref: vccadc-ref {
|
||||
|