sunxi: axp221: Fix using the wrong register address for ALDO2
This fixes us never programming ALDO2, and programming the ALDO2 voltage into ALDo1. Reported-by: Siarhei Siamashka <siarhei.siamashka@gmail.com> Signed-off-by: Hans de Goede <hdegoede@redhat.com>
This commit is contained in:
parent
d622ac3927
commit
5ba471944a
@ -32,7 +32,7 @@
|
||||
#define AXP221_DCDC4_CTRL 0x24
|
||||
#define AXP221_DCDC5_CTRL 0x25
|
||||
#define AXP221_ALDO1_CTRL 0x28
|
||||
#define AXP221_ALDO2_CTRL 0x28
|
||||
#define AXP221_ALDO2_CTRL 0x29
|
||||
#define AXP221_ALDO3_CTRL 0x2a
|
||||
|
||||