clk: agilex: Handle clock configuration differently in SPL and U-Boot proper
Since warm reset may optionally set the CLock Manager to'boot mode', the clock driver should always force the Agilex's Clock Manager to 'boot mode' before the clock driver start configuring the Clock Manager in SPL. In SSBL, clock driver will skip the Clock Manager configuration if it's already being setup by SPL (Clock Manager NOT in 'boot mode') to prevent any inaccurate clocking issues happened on HPS peripherals such as UART, MAC and etc. Signed-off-by: Chee Hong Ang <chee.hong.ang@intel.com>
This commit is contained in:
committed by
Ley Foon Tan
parent
d3e829b618
commit
35d847ed90
@@ -171,6 +171,16 @@ static void clk_basic_init(struct udevice *dev,
|
||||
if (!cfg)
|
||||
return;
|
||||
|
||||
#ifdef CONFIG_SPL_BUILD
|
||||
/* Always force clock manager into boot mode before any configuration */
|
||||
clk_write_ctrl(plat,
|
||||
CM_REG_READL(plat, CLKMGR_CTRL) | CLKMGR_CTRL_BOOTMODE);
|
||||
#else
|
||||
/* Skip clock configuration in SSBL if it's not in boot mode */
|
||||
if (!(CM_REG_READL(plat, CLKMGR_CTRL) & CLKMGR_CTRL_BOOTMODE))
|
||||
return;
|
||||
#endif
|
||||
|
||||
/* Put both PLLs in bypass */
|
||||
clk_write_bypass_mainpll(plat, CLKMGR_BYPASS_MAINPLL_ALL);
|
||||
clk_write_bypass_perpll(plat, CLKMGR_BYPASS_PERPLL_ALL);
|
||||
|
||||
Reference in New Issue