Thierry Reding 562da8b494 arm64: tegra: Use valid PWM period for VDD_GPU on Tegra210
The PWM on Tegra210 can run at a maximum frequency of 48 MHz and cannot
reach the minimum period is 5334 ns. The currently configured period of
4880 ns is not within the valid range, so set it to 8000 ns. This value
was taken from the downstream DTS files and seems to work fine.