Fix the comment style that matches existing code.
No functionality change in this patch.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
In our application, we need a way to force TCP connections to go out a
specific IP interface instead of letting Linux select the interface
based on the routing tables.
Add the 'host-iface' option to allow specifying the interface to use.
When the option host-iface is specified, the driver uses the specified
interface to set the option SO_BINDTODEVICE on the TCP socket before
connecting.
This new option is needed in addtion to the existing host-traddr for
the following reasons:
Specifying an IP interface by its associated IP address is less
intuitive than specifying the actual interface name and, in some cases,
simply doesn't work. That's because the association between interfaces
and IP addresses is not predictable. IP addresses can be changed or can
change by themselves over time (e.g. DHCP). Interface names are
predictable [1] and will persist over time. Consider the following
configuration.
1: lo: <LOOPBACK,UP,LOWER_UP> mtu 65536 qdisc noqueue state ...
link/loopback 00:00:00:00:00:00 brd 00:00:00:00:00:00
inet 100.0.0.100/24 scope global lo
valid_lft forever preferred_lft forever
2: enp0s3: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc ...
link/ether 08:00:27:21:65:ec brd ff:ff:ff:ff:ff:ff
inet 100.0.0.100/24 scope global enp0s3
valid_lft forever preferred_lft forever
3: enp0s8: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc ...
link/ether 08:00:27:4f:95:5c brd ff:ff:ff:ff:ff:ff
inet 100.0.0.100/24 scope global enp0s8
valid_lft forever preferred_lft forever
The above is a VM that I configured with the same IP address
(100.0.0.100) on all interfaces. Doing a reverse lookup to identify the
unique interface associated with 100.0.0.100 does not work here. And
this is why the option host_iface is required. I understand that the
above config does not represent a standard host system, but I'm using
this to prove a point: "We can never know how users will configure
their systems". By te way, The above configuration is perfectly fine
by Linux.
The current TCP implementation for host_traddr performs a
bind()-before-connect(). This is a common construct to set the source
IP address on a TCP socket before connecting. This has no effect on how
Linux selects the interface for the connection. That's because Linux
uses the Weak End System model as described in RFC1122 [2]. On the other
hand, setting the Source IP Address has benefits and should be supported
by linux-nvme. In fact, setting the Source IP Address is a mandatory
FedGov requirement (e.g. connection to a RADIUS/TACACS+ server).
Consider the following configuration.
$ ip addr list dev enp0s8
3: enp0s8: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc ...
link/ether 08:00:27:4f:95:5c brd ff:ff:ff:ff:ff:ff
inet 192.168.56.101/24 brd 192.168.56.255 scope global enp0s8
valid_lft 426sec preferred_lft 426sec
inet 192.168.56.102/24 scope global secondary enp0s8
valid_lft forever preferred_lft forever
inet 192.168.56.103/24 scope global secondary enp0s8
valid_lft forever preferred_lft forever
inet 192.168.56.104/24 scope global secondary enp0s8
valid_lft forever preferred_lft forever
Here we can see that several addresses are associated with interface
enp0s8. By default, Linux always selects the default IP address,
192.168.56.101, as the source address when connecting over interface
enp0s8. Some users, however, want the ability to specify a different
source address (e.g., 192.168.56.102, 192.168.56.103, ...). The option
host_traddr can be used as-is to perform this function.
In conclusion, I believe that we need 2 options for TCP connections.
One that can be used to specify an interface (host-iface). And one that
can be used to set the source address (host-traddr). Users should be
allowed to use one or the other, or both, or none. Of course, the
documentation for host_traddr will need some clarification. It should
state that when used for TCP connection, this option only sets the
source address. And the documentation for host_iface should say that
this option is only available for TCP connections.
References:
[1] https://www.freedesktop.org/wiki/Software/systemd/PredictableNetworkInterfaceNames/
[2] https://tools.ietf.org/html/rfc1122
Tested both IPv4 and IPv6 connections.
Signed-off-by: Martin Belanger <martin.belanger@dell.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: Hannes Reinecke <hare@suse.de>
Signed-off-by: Christoph Hellwig <hch@lst.de>
The algorithm that was used until now for building the APST configuration
table has been found to produce entries with excessively long ITPT
(idle time prior to transition) for devices declaring relatively long
entry and exit latencies for non-operational power states. This leads
to unnecessary waste of power and, as a result, failure to pass
mandatory power consumption tests on Chromebook platforms.
The new algorithm is based on two predefined ITPT values and two
predefined latency tolerances. Based on these values, as well as on
exit and entry latencies reported by the device, the algorithm looks
for up to 2 suitable non-operational power states to use as primary
and secondary APST transition targets. The predefined values are
supplied to the nvme driver as module parameters:
- apst_primary_timeout_ms (default: 100)
- apst_secondary_timeout_ms (default: 2000)
- apst_primary_latency_tol_us (default: 15000)
- apst_secondary_latency_tol_us (default: 100000)
The algorithm echoes the approach used by Intel's and Microsoft's drivers
on Windows. The specific default parameter values are also based on those
drivers. Yet, this patch doesn't introduce the ability to dynamically
regenerate the APST table in the event of switching the power source from
AC to battery and back. Adding this functionality may be considered in the
future. In the meantime, the timeouts and tolerances reflect a compromise
between values used by Microsoft for AC and battery scenarios.
In most NVMe devices the new algorithm causes them to implement a more
aggressive power saving policy. While beneficial in most cases, this
sometimes comes at the price of a higher IO processing latency in certain
scenarios as well as at the price of a potential impact on the drive's
endurance (due to more frequent context saving when entering deep non-
operational states). So in order to provide a fallback for systems where
these regressions cannot be tolerated, the patch allows to revert to
the legacy behavior by setting either apst_primary_timeout_ms or
apst_primary_latency_tol_us parameter to 0. Eventually (and possibly after
fine tuning the default values of the module parameters) the legacy behavior
can be removed.
TESTING.
The new algorithm has been extensively tested. Initially, simulations were
used to compare APST tables generated by old and new algorithms for a wide
range of devices. After that, power consumption, performance and latencies
were measured under different workloads on devices from multiple vendors
(WD, Intel, Samsung, Hynix, Kioxia). Below is the description of the tests
and the findings.
General observations.
The effect the patch has on the APST table varies depending on the entry and
exit latencies advertised by the devices. For some devices, the effect is
negligible (e.g. Kioxia KBG40ZNS), for some significant, making the
transitions to PS3 and PS4 much quicker (e.g. WD SN530, Intel 760P), or making
the sleep deeper, PS4 rather than PS3 after a similar amount of time (e.g.
SK Hynix BC511). For some devices (e.g. Samsung PM991) the effect is mixed:
the initial transition happens after a longer idle time, but takes the device
to a lower power state.
Workflows.
In order to evaluate the patch's effect on the power consumption and latency,
7 workflows were used for each device. The workflows were designed to test
the scenarios where significant differences between the old and new behaviors
are most likely. Each workflow was tested twice: with the new and with the
old APST table generation implementation. Power consumption, performance and
latency were measured in the process. The following workflows were used:
1) Consecutive write at the maximum rate with IO depth of 2, with no pauses
2) Repeated pattern of 1000 consecutive writes of 4K packets followed by 50ms
idle time
3) Repeated pattern of 1000 consecutive writes of 4K packets followed by 150ms
idle time
4) Repeated pattern of 1000 consecutive writes of 4K packets followed by 500ms
idle time
5) Repeated pattern of 1000 consecutive writes of 4K packets followed by 1.5s
idle time
6) Repeated pattern of 1000 consecutive writes of 4K packets followed by 5s
idle time
7) Repeated pattern of a single random read of a 4K packet followed by 150ms
idle time
Power consumption
Actual power consumption measurements produced predictable results in
accordance with the APST mechanism's theory of operation.
Devices with long entry and exit latencies such as WD SN530 showed huge
improvement on scenarios 4,5 and 6 of up to 62%. Devices such as Kioxia
KBG40ZNS where the resulting APST table looks virtually identical with
both legacy and new algorithms, showed little or no change in the average power
consumption on all workflows. Devices with extra short latencies such as
Samsung PM991 showed moderate increase in power consumption of up to 18% in
worst case scenarios.
In addition, on Intel and Samsung devices a more complex impact was observed
on scenarios 3, 4 and 7. Our understanding is that due to longer stay in deep
non-operational states between the writes the devices start performing background
operations leading to an increase of power consumption. With the old APST tables
part of these operations are delayed until the scenario is over and a longer idle
period begins, but eventually this extra power is consumed anyway.
Performance.
In terms of performance measured on sustained write or read scenarios, the
effect of the patch is minimal as in this case the device doesn't enter low power
states.
Latency
As expected, in devices where the patch causes a more aggressive power saving
policy (e.g. WD SN530, Intel 760P), an increase in latency was observed in
certain scenarios. Workflow number 7, specifically designed to simulate the
worst case scenario as far as latency is concerned, indeed shows a sharp
increase in average latency (~2ms -> ~53ms on Intel 760P and 0.6 -> 10ms on
WD SN530). The latency increase on other workloads and other devices is much
milder or non-existent.
Signed-off-by: Alexey Bogoslavsky <alexey.bogoslavsky@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
The variable ret is being initialized with a value that is never read,
it is being updated later on. The assignment is redundant and can be
removed.
Signed-off-by: Colin Ian King <colin.king@canonical.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
In case p2p device was found but the p2p pool is empty, the nvme target
is still trying to free the sgl from the p2p pool instead of the
regular sgl pool and causing a crash (BUG() is called). Instead, assign
the p2p_dev for the request only if it was allocated from p2p pool.
This is the crash that was caused:
[Sun May 30 19:13:53 2021] ------------[ cut here ]------------
[Sun May 30 19:13:53 2021] kernel BUG at lib/genalloc.c:518!
[Sun May 30 19:13:53 2021] invalid opcode: 0000 [#1] SMP PTI
...
[Sun May 30 19:13:53 2021] kernel BUG at lib/genalloc.c:518!
...
[Sun May 30 19:13:53 2021] RIP: 0010:gen_pool_free_owner+0xa8/0xb0
...
[Sun May 30 19:13:53 2021] Call Trace:
[Sun May 30 19:13:53 2021] ------------[ cut here ]------------
[Sun May 30 19:13:53 2021] pci_free_p2pmem+0x2b/0x70
[Sun May 30 19:13:53 2021] pci_p2pmem_free_sgl+0x4f/0x80
[Sun May 30 19:13:53 2021] nvmet_req_free_sgls+0x1e/0x80 [nvmet]
[Sun May 30 19:13:53 2021] kernel BUG at lib/genalloc.c:518!
[Sun May 30 19:13:53 2021] nvmet_rdma_release_rsp+0x4e/0x1f0 [nvmet_rdma]
[Sun May 30 19:13:53 2021] nvmet_rdma_send_done+0x1c/0x60 [nvmet_rdma]
Fixes: c6e3f13398 ("nvmet: add metadata support for block devices")
Reviewed-by: Israel Rukshin <israelr@nvidia.com>
Signed-off-by: Max Gurtovoy <mgurtovoy@nvidia.com>
Reviewed-by: Logan Gunthorpe <logang@deltatee.com>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
During concurrent reset and delete calls the reset workqueue is
flushed, causing nvme_loop_reset_ctrl_work() to be executed when
the controller is in state DELETING or DELETING_NOIO.
But this is expected, so we shouldn't issue a WARN_ON here.
Signed-off-by: Hannes Reinecke <hare@suse.de>
Signed-off-by: Christoph Hellwig <hch@lst.de>
We need to check the NVME_LOOP_Q_LIVE flag in
nvme_loop_destroy_admin_queue() to protect against duplicate
invocations eg during concurrent reset and remove calls.
Signed-off-by: Hannes Reinecke <hare@suse.de>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
When the call to nvme_enable_ctrl() in nvme_loop_configure_admin_queue()
fails the NVME_LOOP_Q_LIVE flag is not cleared.
Signed-off-by: Hannes Reinecke <hare@suse.de>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
The queue count is increased in nvme_loop_init_io_queues(), so we
need to reset it to 1 at the end of nvme_loop_destroy_io_queues().
Otherwise the function is not re-entrant safe, and crash will happen
during concurrent reset and remove calls.
Signed-off-by: Hannes Reinecke <hare@suse.de>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Convert the nvme-multipath driver to use the blk_alloc_disk and
blk_cleanup_disk helpers to simplify gendisk and request_queue
allocation.
Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Ulf Hansson <ulf.hansson@linaro.org>
Link: https://lore.kernel.org/r/20210521055116.1053587-19-hch@lst.de
Signed-off-by: Jens Axboe <axboe@kernel.dk>
Automatically set the GENHD_FL_EXT_DEVT flag for all disks allocated
without an explicit number of minors. This is what all new block
drivers should do, so make sure it is the default without boilerplate
code.
Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Hannes Reinecke <hare@suse.de>
Reviewed-by: Luis Chamberlain <mcgrof@kernel.org>
Reviewed-by: Ulf Hansson <ulf.hansson@linaro.org>
Link: https://lore.kernel.org/r/20210521055116.1053587-4-hch@lst.de
Signed-off-by: Jens Axboe <axboe@kernel.dk>
We have only 2 inline sg entries and we allow 4 sg entries for the send
wr sge. Larger sgls entries will be chained. However when we build
in-capsule send wr sge, we iterate without taking into account that the
sgl may be chained and still fit in-capsule (which can happen if the sgl
is bigger than 2, but lower-equal to 4).
Fix in-capsule data mapping to correctly iterate chained sgls.
Fixes: 38e1800275 ("nvme-rdma: Avoid preallocating big SGL for data")
Reported-by: Walker, Benjamin <benjamin.walker@intel.com>
Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: Max Gurtovoy <mgurtovoy@nvidia.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Controller teardown flow may take some time in case it has many I/O
queues, and the host may not send us keep-alive during this period.
Hence reset the traffic based keep-alive timer so we don't trigger
a controller teardown as a result of a keep-alive expiration.
Reported-by: Yi Zhang <yi.zhang@redhat.com>
Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Reviewed-by: Hannes Reinecke <hare@suse.de>
Tested-by: Yi Zhang <yi.zhang@redhat.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Using "<=" instead "<" to compare inline data size.
Fixes: bdaf132791 ("nvmet-tcp: fix a segmentation fault during io parsing error")
Signed-off-by: Hou Pu <houpu.main@gmail.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
We need to select NVME_CORE.
Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: Max Gurtovoy <mgurtovoy@nvidia.com>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Returning an nvme status from nvme_fc_create_association() indicates
that the association is established, and we should honour the DNR bit.
If it's set a reconnect attempt will just return the same error, so
we can short-circuit the reconnect attempts and fail the connection
directly.
Signed-off-by: Hannes Reinecke <hare@suse.de>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: Himanshu Madhani <himanshu.madhani@oracle.com>
Reviewed-by: James Smart <jsmart2021@gmail.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
The __nvmf_check_ready() routine used to bounce all filesystem io if the
controller state isn't LIVE. However, a later patch changed the logic so
that it rejection ends up being based on the Q live check. The FC
transport has a slightly different sequence from rdma and tcp for
shutting down queues/marking them non-live. FC marks its queue non-live
after aborting all ios and waiting for their termination, leaving a
rather large window for filesystem io to continue to hit the transport.
Unfortunately this resulted in filesystem I/O or applications seeing I/O
errors.
Change the FC transport to mark the queues non-live at the first sign of
teardown for the association (when I/O is initially terminated).
Fixes: 73a5379937 ("nvme-fabrics: allow to queue requests for live queues")
Signed-off-by: James Smart <jsmart2021@gmail.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: Himanshu Madhani <himanshu.madhani@oracle.com>
Reviewed-by: Hannes Reinecke <hare@suse.de>
Signed-off-by: Christoph Hellwig <hch@lst.de>
A possible race condition exists where the request to send data is
enqueued from nvme_tcp_handle_r2t()'s will not be observed by
nvme_tcp_send_all() if it happens to be running. The driver relies on
io_work to send the enqueued request when it is runs again, but the
concurrently running nvme_tcp_send_all() may not have released the
send_mutex at that time. If no future commands are enqueued to re-kick
the io_work, the request will timeout in the SEND_H2C state, resulting
in a timeout error like:
nvme nvme0: queue 1: timeout request 0x3 type 6
Ensure the io_work continues to run as long as the req_list is not empty.
Fixes: db5ad6b7f8 ("nvme-tcp: try to send request in queue_rq context")
Signed-off-by: Keith Busch <kbusch@kernel.org>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Commit db5ad6b7f8 ("nvme-tcp: try to send request in queue_rq
context") added a second context that may perform a network send.
This means that now RX and TX are not serialized in nvme_tcp_io_work
and can run concurrently.
While there is correct mutual exclusion in the TX path (where
the send_mutex protect the queue socket send activity) RX activity,
and more specifically request completion may run concurrently.
This means we must guarantee that any mutation of the request state
related to its lifetime, bytes sent must not be accessed when a completion
may have possibly arrived back (and processed).
The race may trigger when a request completion arrives, processed
_and_ reused as a fresh new request, exactly in the (relatively short)
window between the last data payload sent and before the request iov_iter
is advanced.
Consider the following race:
1. 16K write request is queued
2. The nvme command and the data is sent to the controller (in-capsule
or solicited by r2t)
3. After the last payload is sent but before the req.iter is advanced,
the controller sends back a completion.
4. The completion is processed, the request is completed, and reused
to transfer a new request (write or read)
5. The new request is queued, and the driver reset the request parameters
(nvme_tcp_setup_cmd_pdu).
6. Now context in (2) resumes execution and advances the req.iter
==> use-after-completion as this is already a new request.
Fix this by making sure the request is not advanced after the last
data payload send, knowing that a completion may have arrived already.
An alternative solution would have been to delay the request completion
or state change waiting for reference counting on the TX path, but besides
adding atomic operations to the hot-path, it may present challenges in
multi-stage R2T scenarios where a r2t handler needs to be deferred to
an async execution.
Reported-by: Narayan Ayalasomayajula <narayan.ayalasomayajula@wdc.com>
Tested-by: Anil Mishra <anil.mishra@wdc.com>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Cc: stable@vger.kernel.org # v5.8+
Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
When creating loop ctrl in nvme_loop_create_ctrl(), if nvme_init_ctrl()
fails, the loop ctrl should be freed before jumping to the "out" label.
Fixes: 3a85a5de29 ("nvme-loop: add a NVMe loopback host driver")
Signed-off-by: Wu Bo <wubo40@huawei.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
When creating ctrl in nvmet_alloc_ctrl(), if the cntlid_min is larger
than cntlid_max of the subsystem, and jumps to the
"out_free_changed_ns_list" label, but the ctrl->sqs lack of be freed.
Fix this by jumping to the "out_free_sqs" label.
Fixes: 94a39d61f8 ("nvmet: make ctrl-id configurable")
Signed-off-by: Wu Bo <wubo40@huawei.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Reset the ns->file value to NULL also in the error case in
nvmet_file_ns_enable().
The ns->file variable points either to file object or contains the
error code after the filp_open() call. This can lead to following
problem:
When the user first setups an invalid file backend and tries to enable
the ns, it will fail. Then the user switches over to a bdev backend
and enables successfully the ns. The first received I/O will crash the
system because the IO backend is chosen based on the ns->file value:
static u16 nvmet_parse_io_cmd(struct nvmet_req *req)
{
[...]
if (req->ns->file)
return nvmet_file_parse_io_cmd(req);
return nvmet_bdev_parse_io_cmd(req);
}
Reported-by: Enzo Matsumiya <ematsumiya@suse.com>
Signed-off-by: Daniel Wagner <dwagner@suse.de>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Host can send invalid commands and flood the target with error messages.
Demote the error message from pr_err() to pr_debug() in
nvmet_parse_fabrics_cmd() and nvmet_parse_connect_cmd().
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Use the helper nvmet_report_invalid_opcode() to report invalid opcode
so we can remove the duplicate code.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Host can send invalid commands and flood the target with error messages
for the discovery controller. Demote the error message from pr_err() to
pr_debug( in nvmet_parse_discovery_cmd().
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
When handling passthru commands, for inline bio allocation we only
consider the transfer size. This works well when req->sg_cnt fits into
the req->inline_bvec, but it will result in the early return from
bio_add_hw_page() when req->sg_cnt > NVMET_MAX_INLINE_BVEC.
Consider an I/O of size 32768 and first buffer is not aligned to the
page boundary, then I/O is split in following manner :-
[ 2206.256140] nvmet: sg->length 3440 sg->offset 656
[ 2206.256144] nvmet: sg->length 4096 sg->offset 0
[ 2206.256148] nvmet: sg->length 4096 sg->offset 0
[ 2206.256152] nvmet: sg->length 4096 sg->offset 0
[ 2206.256155] nvmet: sg->length 4096 sg->offset 0
[ 2206.256159] nvmet: sg->length 4096 sg->offset 0
[ 2206.256163] nvmet: sg->length 4096 sg->offset 0
[ 2206.256166] nvmet: sg->length 4096 sg->offset 0
[ 2206.256170] nvmet: sg->length 656 sg->offset 0
Now the req->transfer_size == NVMET_MAX_INLINE_DATA_LEN i.e. 32768, but
the req->sg_cnt is (9) > NVMET_MAX_INLINE_BIOVEC which is (8).
This will result in early return in the following code path :-
nvmet_bdev_execute_rw()
bio_add_pc_page()
bio_add_hw_page()
if (bio_full(bio, len))
return 0;
Use previously introduced helper nvmet_use_inline_bvec() to consider
req->sg_cnt when using inline bio. This only affects nvme-loop
transport.
Fixes: dab3902b19 ("nvmet: use inline bio for passthru fast path")
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
When handling rw commands, for inline bio case we only consider
transfer size. This works well when req->sg_cnt fits into the
req->inline_bvec, but it will result in the warning in
__bio_add_page() when req->sg_cnt > NVMET_MAX_INLINE_BVEC.
Consider an I/O size 32768 and first page is not aligned to the page
boundary, then I/O is split in following manner :-
[ 2206.256140] nvmet: sg->length 3440 sg->offset 656
[ 2206.256144] nvmet: sg->length 4096 sg->offset 0
[ 2206.256148] nvmet: sg->length 4096 sg->offset 0
[ 2206.256152] nvmet: sg->length 4096 sg->offset 0
[ 2206.256155] nvmet: sg->length 4096 sg->offset 0
[ 2206.256159] nvmet: sg->length 4096 sg->offset 0
[ 2206.256163] nvmet: sg->length 4096 sg->offset 0
[ 2206.256166] nvmet: sg->length 4096 sg->offset 0
[ 2206.256170] nvmet: sg->length 656 sg->offset 0
Now the req->transfer_size == NVMET_MAX_INLINE_DATA_LEN i.e. 32768, but
the req->sg_cnt is (9) > NVMET_MAX_INLINE_BIOVEC which is (8).
This will result in the following warning message :-
nvmet_bdev_execute_rw()
bio_add_page()
__bio_add_page()
WARN_ON_ONCE(bio_full(bio, len));
This scenario is very hard to reproduce on the nvme-loop transport only
with rw commands issued with the passthru IOCTL interface from the host
application and the data buffer is allocated with the malloc() and not
the posix_memalign().
Fixes: 73383adfad ("nvmet: don't split large I/Os unconditionally")
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
nvme_init_identify and thus nvme_mpath_init can be called multiple
times and thus must not overwrite potentially initialized or in-use
fields. Split out a helper for the basic initialization when the
controller is initialized and make sure the init_identify path does
not blindly change in-use data structures.
Fixes: 0d0b660f21 ("nvme: add ANA support")
Reported-by: Martin Wilck <mwilck@suse.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: Hannes Reinecke <hare@suse.de>
Nothing can stop a host from submitting invalid commands. The target
just needs to respond with an appropriate status, but that's not a
target error. Demote invalid command messages to the debug level so
these events don't spam the kernel logs.
Reported-by: Yi Zhang <yi.zhang@redhat.com>
Signed-off-by: Keith Busch <kbusch@kernel.org>
Reviewed-by: Klaus Jensen <k.jensen@samsung.com>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
When a request finally completes in end_io() after it has failed over,
the bdev pointer can be stale and thus the system can crash. Set the
bdev back to ns head, so the request is map to an active path when
resubmitted.
Signed-off-by: Daniel Wagner <dwagner@suse.de>
Reviewed-by: Hannes Reinecke <hare@suse.de>
Signed-off-by: Christoph Hellwig <hch@lst.de>
reset_work() in nvme-pci may hang forever in the following scenario:
1) A reset caused by a command timeout occurs due to a controller being
temporarily irresponsive.
2) nvme_reset_work() restarts admin queue at nvme_alloc_admin_tags(). At
the same time, a user-submitted admin command is queued and waiting
for completion. Then, reset_work() changes its state to CONNECTING,
and submits an identify command.
3) However, the controller does still not respond to any command,
causing a timeout being fired at the user-submitted command.
Unfortunately, nvme_timeout() does not see the completion on cq, and
any timeout that takes place under CONNECTING state causes a
controller shutdown.
4) Normally, the identify command in reset_work() would be canceled with
SC_HOST_ABORTED by nvme_dev_disable(), then reset_work can tear down
the controller accordingly. But the controller happens to return
online and respond the identify command before nvme_dev_disable()
should have been reaped it off.
5) reset_work() continues to setup_io_queues() as it observes no error
in init_identify(). However, the admin queue has already been
quiesced in dev_disable(). Thus, any following commands would be
blocked forever in blk_execute_rq().
This can be fixed by restricting usercmd commands when controller is not
in a LIVE state in nvme_queue_rq(), as what has been done previously in
fabrics.
```
nvme_reset_work(): |
nvme_alloc_admin_tags() |
| nvme_submit_user_cmd():
nvme_init_identify(): | ...
__nvme_submit_sync_cmd(): |
... | ...
---------------------------------------> nvme_timeout():
(Controller starts reponding commands) | nvme_dev_disable(, true):
nvme_setup_io_queues(): |
__nvme_submit_sync_cmd(): |
(hung in blk_execute_rq |
since run_hw_queue sees |
queue quiesced) |
```
Signed-off-by: Tao Chiu <taochiu@synology.com>
Signed-off-by: Cody Wong <codywong@synology.com>
Reviewed-by: Leon Chien <leonchien@synology.com>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Signed-off-by: Christoph Hellwig <hch@lst.de>
queue_rq() in pci only checks if the dispatched queue (nvmeq) is ready,
e.g. not being suspended. Since nvme_alloc_admin_tags() in reset flow
restarts the admin queue, users are able to submit admin commands to a
controller before reset_work() completes. Commands submitted under this
condition may interfere with commands that performs identify, IO queue
setup in reset_work(), and may result in a hang described in the
following patch.
As seen in the fabrics, user commands are prevented from being executed
under inproper controller states. We may reuse this logic to maintain a
clear admin queue during reset_work().
Signed-off-by: Tao Chiu <taochiu@synology.com>
Signed-off-by: Cody Wong <codywong@synology.com>
Reviewed-by: Leon Chien <leonchien@synology.com>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Signed-off-by: Christoph Hellwig <hch@lst.de>
nvme_clear_nvme_request() clears the nvme_command, which is unncessary
for passthrough requests as nvme_command is overwritten immediately.
Move clearing part from this helper to the caller, so that double memset
for passthrough requests is avoided.
Signed-off-by: Kanchan Joshi <joshi.k@samsung.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
In multipath case, we should consider namespace attachment with
controllers in a subsystem when we find out the live controller for the
namespace. This patch manually reverted the commit 3557a44097
("nvme: don't bother to look up a namespace for controller ioctls") with
few more updates to nvme_ns_head_chr_ioctl which has been newly updated.
Fixes: 3557a44097 ("nvme: don't bother to look up a namespace for
controller ioctls")
Cc: Christoph Hellwig <hch@lst.de>
Signed-off-by: Minwoo Im <minwoo.im.dev@gmail.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Userspace has not been allowed to I/O to device that's failed to
be initialized. This patch introduces generic per-namespace character
device to allow userspace to I/O regardless the block device is there or
not.
The chardev naming convention will similar to the existing blkdev naming,
using a ng prefix instead of nvme, i.e.
- /dev/ngXnY
It also supports multipath which means it will not expose chardev for the
hidden namespace blkdevs (e.g., nvmeXcYnZ). If /dev/ngXnY is created for
a ns_head, then I/O request will be routed to a specific controller
selected by the iopolicy of the subsystem.
Signed-off-by: Minwoo Im <minwoo.im.dev@gmail.com>
Signed-off-by: Javier González <javier.gonz@samsung.com>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Tested-by: Kanchan Joshi <joshi.k@samsung.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Remove a level of indentation from the main code implementating the table
search by using a goto for the APST not supported case. Also move the
main comment above the function.
Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Niklas Cassel <niklas.cassel@wdc.com>
Do not call nvme_configure_apst when the controller is not live, given
that nvme_configure_apst will fail due the lack of an admin queue when
the controller is being torn down and nvme_set_latency_tolerance is
called from dev_pm_qos_hide_latency_tolerance.
Fixes: 510a405d945b("nvme: fix memory leak for power latency tolerance")
Reported-by: Peng Liu <liupeng17@lenovo.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Add a 'kato' controller sysfs attribute to display the current
keep-alive timeout value (if any). This allows userspace to identify
persistent discovery controllers, as these will have a non-zero
KATO value.
Signed-off-by: Hannes Reinecke <hare@suse.de>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
According to the NVMe base spec the KATO commands should be sent
at half of the KATO interval, to properly account for round-trip
times.
As we now will only ever send one KATO command per connection we
can easily use the recommended values.
This also fixes a potential issue where the request timeout for
the KATO command does not match the value in the connect command,
which might be causing spurious connection drops from the target.
Signed-off-by: Hannes Reinecke <hare@suse.de>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Issue following command:
nvme set-feature -f 0xf -v 0 /dev/nvme1n1 # disable keep-alive timer
nvme admin-passthru -o 0x18 /dev/nvme1n1 # send keep-alive command
will make keep-alive timer fired and thus delete the controller like
below:
[247459.907635] nvmet: ctrl 1 keep-alive timer (0 seconds) expired!
[247459.930294] nvmet: ctrl 1 fatal error occurred!
Avoid this by not queuing delayed keep-alive if it is disabled when
keep-alive command is received from the admin queue.
Signed-off-by: Hou Pu <houpu.main@gmail.com>
Tested-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Adding entry for dev_attr_fast_io_fail_tmo to avoid the kernel crash
while reading and writing the fast_io_fail_tmo.
Fixes: 09fbed6363 (nvme: export fast_io_fail_tmo to sysfs)
Signed-off-by: Gopal Tiwari <gtiwari@redhat.com>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Instead of failing to scan the namespace entirely when unsupported
features are detected, just mark the gendisk hidden but allow other
access like the upcoming per-namespace character device.
Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Reviewed-by: Javier González <javier.gonz@samsung.com>
These will be reused for the per-namespace character devices.
Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Reviewed-by: Javier González <javier.gonz@samsung.com>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Move the multipath block_device_operations to multipath.c, where they
belong.
Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Reviewed-by: Javier González <javier.gonz@samsung.com>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Split out the ioctl code from core.c into a new file. Also update
copyrights while we're at it.
Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Reviewed-by: Javier González <javier.gonz@samsung.com>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Don't bother to look up a namespace just to drop if after retreiving the
controller for the multipath case. Just look up a live controller for
the subsystem directly.
Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Reviewed-by: Javier González <javier.gonz@samsung.com>
Only use the existing ioctl handler for the multipath case, and add a
simpler one that reverts to the pre-multipath case for not shared
use case.
Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Reviewed-by: Javier González <javier.gonz@samsung.com>
Don't bother defining a separate compat_ioctl handler, and just handle
the NVME_IOCTL_SUBMIT_IO32 case inline. Also only defined it for those
ABIs (currently just i386 vs x86_64) that are affected.
Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Reviewed-by: Javier González <javier.gonz@samsung.com>
Factor out a helper for the namespace based ioctls.
Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Reviewed-by: Javier González <javier.gonz@samsung.com>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Pass the proper user pointer instead of the not all that useful integer
representation.
Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Reviewed-by: Javier González <javier.gonz@samsung.com>
Return false from nvme_set_disk_name and let the caller set the
non-multipath name instead of duplicating the naming information in two
places. Also remove the pointless local variables for the disk name
and flags and the not needed ctrl argument.
Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Reviewed-by: Javier González <javier.gonz@samsung.com>
Move the multipath gendisk out of #ifdef CONFIG_NVME_MULTIPATH and add
a new nvme_ns_head_multipath that uses it to check if a ns_head has
a multipath device associated with it.
Signed-off-by: Minwoo Im <minwoo.im.dev@gmail.com>
[hch: added the IS_ENABLED, converted a few existing users]
Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Reviewed-by: Javier González <javier.gonz@samsung.com>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
There is a single trailing whitespace in core.c.
Since this is just a single whitespace, the chances of this affecting
backports to stable should be quite low, so let's just remove it.
Signed-off-by: Niklas Cassel <niklas.cassel@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
There is a single trailing whitespace in multipath.c.
Since this is just a single whitespace, the chances of this affecting
backports to stable should be quite low, so let's just remove it.
Signed-off-by: Niklas Cassel <niklas.cassel@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
There is a single trailing whitespace in pci.c.
Since this is just a single whitespace, the chances of this affecting
backports to stable should be quite low, so let's just remove it.
Signed-off-by: Niklas Cassel <niklas.cassel@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
According to the module parameter description for sgl_threshold,
a value of 0 means that SGLs are disabled.
If SGLs are disabled, we should respect that, even for the case
where the request is made up of a single physical segment.
Fixes: 297910571f ("nvme-pci: optimize mapping single segment requests using SGLs")
Signed-off-by: Niklas Cassel <niklas.cassel@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
There is a spelling mistake in a pr_err error message. Fix it.
Signed-off-by: Colin Ian King <colin.king@canonical.com>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Once a host is already created, avoid allocate additional hostports that
will be thrown away. add an helper function to handle host search.
Reviewed-by: Himanshu Madhani <himanshu.madhani@oracle.com>
Signed-off-by: James Smart <jsmart2021@gmail.com>
Signed-off-by: Amit Engel <amit.engel@dell.com>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
In case there is an io that contains inline data and it goes to
parsing error flow, command response will free command and iov
before clearing the data on the socket buffer.
This will delay the command response until receive flow is completed.
Fixes: 872d26a391 ("nvmet-tcp: add NVMe over TCP target driver")
Signed-off-by: Elad Grupi <elad.grupi@dell.com>
Signed-off-by: Hou Pu <houpu.main@gmail.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
list_sort() internally casts the comparison function passed to it
to a different type with constant struct list_head pointers, and
uses this pointer to call the functions, which trips indirect call
Control-Flow Integrity (CFI) checking.
Instead of removing the consts, this change defines the
list_cmp_func_t type and changes the comparison function types of
all list_sort() callers to use const pointers, thus avoiding type
mismatches.
Suggested-by: Nick Desaulniers <ndesaulniers@google.com>
Signed-off-by: Sami Tolvanen <samitolvanen@google.com>
Reviewed-by: Nick Desaulniers <ndesaulniers@google.com>
Reviewed-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Kees Cook <keescook@chromium.org>
Tested-by: Nick Desaulniers <ndesaulniers@google.com>
Tested-by: Nathan Chancellor <nathan@kernel.org>
Signed-off-by: Kees Cook <keescook@chromium.org>
Link: https://lore.kernel.org/r/20210408182843.1754385-10-samitolvanen@google.com
Instead of overloading the passthrough fast path with the deprecated
block layer bounce buffering let the users that combine an old
undermaintained driver with a highmem system pay the price by always
falling back to copies in that case.
Signed-off-by: Christoph Hellwig <hch@lst.de>
Acked-by: Martin K. Petersen <martin.petersen@oracle.com>
Reviewed-by: Hannes Reinecke <hare@suse.de>
Link: https://lore.kernel.org/r/20210331073001.46776-9-hch@lst.de
Signed-off-by: Jens Axboe <axboe@kernel.dk>
Instead of triggering an integer overflow and undefined behavior if MDTS is
large, set max_hw_sectors to UINT_MAX.
Signed-off-by: Bart Van Assche <bvanassche@acm.org>
Reviewed-by: Keith Busch <kbusch@kernel.org>
[hch: rebased to account for the new nvme_mps_to_sectors helper]
Signed-off-by: Christoph Hellwig <hch@lst.de>
Commands that access LBA contents without a data transfer between the
host historically have not had a spec defined upper limit. The driver
set the queue constraints for such commands to the max data transfer
size just to be safe, but this artificial constraint frequently limits
devices below their capabilities.
The NVMe Workgroup ratified TP4040 defines how a controller may
advertise their non-MDTS limits. Use these if provided and default to
the current constraints if not. Since the Dataset Management command
limits are defined in logical blocks, but without a namespace to tell us
the logical block size, the code defaults to the safe 512b size.
Signed-off-by: Keith Busch <kbusch@kernel.org>
Signed-off-by: Christoph Hellwig <hch@lst.de>
When a passthru command targets a specific namespace, the ns parameter to
nvme_user_cmd()/nvme_user_cmd64() is set. However, there is currently no
validation that the nsid specified in the passthru command targets the
namespace/nsid represented by the block device that the ioctl was
performed on.
Add a check that validates that the nsid in the passthru command matches
that of the supplied namespace.
Signed-off-by: Niklas Cassel <niklas.cassel@wdc.com>
Reviewed-by: Javier González <javier@javigon.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: Kanchan Joshi <joshi.k@samsung.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
If ANA is enabled but no ANA group descriptor is found when creating
a new namespace the ANA log is most likely out of date, so trigger
a re-read. The namespace will be tagged with the NS_ANA_PENDING flag
to exclude it from path selection until the ANA log has been re-read.
Fixes: 32acab3181 ("nvme: implement multipath access to nvme subsystems")
Reported-by: Martin George <marting@netapp.com>
Signed-off-by: Hannes Reinecke <hare@suse.de>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Commit 8c4dfea97f ("nvme-fabrics: reject I/O to offline device")
introduced fast_io_fail_tmo but didn't export the value to sysfs. The
value can be set during the 'nvme connect'. Export the timeout value
to user space via sysfs to allow runtime configuration.
Cc: Victor Gladkov <Victor.Gladkov@kioxia.com>
Signed-off-by: Daniel Wagner <dwagner@suse.de>
Reviewed-by: Ewan D. Milne <emilne@redhat.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: Himanshu Madhani <himanshu.madhaani@oracle.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
If there is an error we will leave the function early. So there
is no need for an else. Remove it.
Signed-off-by: Daniel Wagner <dwagner@suse.de>
Signed-off-by: Christoph Hellwig <hch@lst.de>
sysfs_emit is the recommended API to use for formatting strings to be
returned to user space. It is equivalent to scnprintf and aware of the
PAGE_SIZE buffer size.
Suggested-by: Chaitanya Kulkarni <Chaitanya.Kulkarni@wdc.com>
Signed-off-by: Daniel Wagner <dwagner@suse.de>
Signed-off-by: Christoph Hellwig <hch@lst.de>
SGLs support is mandatory for NVMe/FC, make sure that the target is
aligned to the specification.
Signed-off-by: Max Gurtovoy <mgurtovoy@nvidia.com>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
SGLs support is mandatory for NVMe/tcp, make sure that the target is
aligned to the specification.
Signed-off-by: Max Gurtovoy <mgurtovoy@nvidia.com>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Add 'idle_poll_period_usecs' option used by io_work() to support
network devices enabled with advanced interrupt moderation
supporting a relaxed interrupt model. It was discovered that
such a NIC used on the target was unable to support initiator
connection establishment, caused by the existing io_work()
flow that immediately exits after a loop with no activity and
does not re-queue itself.
With this new option a queue is assigned a period of time
that no activity must occur in order to become 'idle'. Until
the queue is idle the work item is requeued.
The new module option is defined as changeable making it
flexible for testing purposes.
The pre-existing legacy behavior is preserved when no module option
for idle_poll_period_usecs is specified.
Signed-off-by: Mark Wunderlich <mark.wunderlich@intel.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
The TCP stack can run from process context for a long time
so we should disable BH here.
Fixes: 3f2304f8c6 ("nvme-tcp: add NVMe over TCP host driver")
Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Return NVME_SC_INVALID_FIELD from discovery controller like normal
controller when executing identify or get log page command.
Signed-off-by: Hou Pu <houpu.main@gmail.com>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
We don't need to repeatedly spam the kernel logs with the same warning
about unhandled passthrough IO effects. Just one warning is sufficient
to observe this condition occurs.
Signed-off-by: Keith Busch <kbusch@kernel.org>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
All nvme transport drivers preallocate an nvme command for each request.
Assume to use that command for nvme_setup_cmd() instead of requiring
drivers pass a pointer to it. All nvme drivers must initialize the
generic nvme_request 'cmd' to point to the transport's preallocated
nvme_command.
The generic nvme_request cmd pointer had previously been used only as a
temporary copy for passthrough commands. Since it now points to the
command that gets dispatched, passthrough commands must directly set it
up prior to executing the request.
Signed-off-by: Keith Busch <kbusch@kernel.org>
Reviewed-by: Jens Axboe <axboe@kernel.dk>
Reviewed-by: Himanshu Madhani <himanshu.madhani@oracle.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Except for pci, all the nvme transport drivers allocate a command within
the driver's pdu. Align pci with everyone else by allocating the nvme
command within pci's pdu and replace the .queue_rq() stack variable with
this.
Signed-off-by: Keith Busch <kbusch@kernel.org>
Reviewed-by: Jens Axboe <axboe@kernel.dk>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Reviewed-by: Himanshu Madhani <himanshu.madhani@oracle.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
According to the NVM specifications, the model number size should be
40 bytes (bytes 63:24 of the Identify Controller data structure).
Therefore, any attempt to store a value into model_number which
exceeds 40 bytes should return an error.
Reviewed-by: Max Gurtovoy <mgurtovoy@nvidia.com>
Signed-off-by: Noam Gottlieb <ngottlieb@nvidia.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
The function nvmet_ctrl_find_get() accepts out pointer to nvmet_ctrl
structure. This function returns the same error value from two places
that is :- NVME_SC_CONNECT_INVALID_PARAM | NVME_SC_DNR.
Move this to the caller so we can change the return type to nvmet_ctrl.
Now that we can changed the return type, instead of taking out pointer
to the nvmet_ctrl structure remove that function parameter and return
the valid nvmet_ctrl pointer on success and NULL on failure.
Also, add and rename the goto labels for more readability with comments.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Add minimum description of the hosthandle parameter for
nvmet_fc_rcv_ls_req() so that we can get rid of the following warning.
drivers/nvme//target/fc.c:2009: warning: Function parameter or member 'hosthandle' not described in 'nvmet_fc_rcv_ls_req
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Reviewed-by: James Smart <jsmart2021@gmail.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
The nvme_fc_rcv_ls_req() function has first argument as pointer to
remoteport named portprt, but in the documentation comment that is name
is used as remoteport. Fix that to get rid if the compilation warning.
drivers/nvme//host/fc.c:1724: warning: Function parameter or member 'portptr' not described in 'nvme_fc_rcv_ls_req'
drivers/nvme//host/fc.c:1724: warning: Excess function parameter 'remoteport' description in 'nvme_fc_rcv_ls_req'
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Reviewed-by: James Smart <jsmart2021@gmail.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Add a new line in functions nvme_pr_preempt(), nvme_pr_clear(), and
nvme_pr_release() after variable declaration which follows the rest of
the code in the nvme/host/core.c.
No functional change(s) in this patch.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
nvme_clear_request() has a check for flag REQ_DONTPREP and it is called
from nvme_init_request() and nvme_setuo_cmd().
The function nvme_init_request() is called from nvme_alloc_request()
and nvme_alloc_request_qid(). From these two callers new request is
allocated everytime. For newly allocated request RQF_DONTPREP is never
set. Since after getting a tag, block layer sets the req->rq_flags == 0
and never sets the REQ_DONTPREP when returning the request :-
nvme_alloc_request()
blk_mq_alloc_request()
blk_mq_rq_ctx_init()
rq->rq_flags = 0 <----
nvme_alloc_request_qid()
blk_mq_alloc_request_hctx()
blk_mq_rq_ctx_init()
rq->rq_flags = 0 <----
The block layer does set req->rq_flags but REQ_DONTPREP is not one of
them and that is set by the driver.
That means we can unconditinally set the REQ_DONTPREP value to the
rq->rq_flags when nvme_init_request()->nvme_clear_request() is called
from above two callers.
Move the check for REQ_DONTPREP from nvme_clear_nvme_request() into
nvme_setup_cmd().
This is needed since nvme_alloc_request() now gets called from fast
path when NVMeOF target is configured with passthru backend to avoid
unnecessary checks in the fast path.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Since nvmet_setup_passthru() function falls in fast path when called
from the NVMeOF passthru backend, make it inline.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
The function nvme_init_ctrl_finish() (formerly nvme_init_identify()) has
grown over the period of time about ~200 lines given the size of nvme id
ctrl data structure.
Move the nvme_id_ctrl data structure related initilzation into helper
nvme_init_identify() and call it from nvme_init_ctrl_finish().
When we move the code into nvme_init_identify() change the local
variable i from int to unsigned int and remove the duplicate kfree()
after nvme_mpath_init() and jump to the label out_free if
nvme_mpath_ini() fails.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
This is a prep patch so that we can move the identify data structure
related code initialization from nvme_init_identify() into a helper.
Rename the function nvmet_init_identify() to nvmet_init_ctrl_finish().
Next patch will move the nvme_id_ctrl related initialization from newly
renamed function nvme_init_ctrl_finish() into the nvme_init_identify()
helper.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
For passthrough I/O commands, effects are usually to be zero.
nvme_passthrough_end() does three checks in futility for this case.
Bail out of function-call/checks.
Signed-off-by: Kanchan Joshi <joshi.k@samsung.com>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Use the proper macro instead of hard-coded value.
Signed-off-by: Kanchan Joshi <joshi.k@samsung.com>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Instead of the using the whitespaces use tab spacing in the
nvmet_execute_identify_ns().
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
In nvmet_check_ctrl_status() cmd can be derived from nvmet_req. Remove
the local variable cmd in the nvmet_check_ctrl_status() and function
parameter cmd for nvmet_check_ctrl_status(). Derive the cmd value from
req parameter in the nvmet_check_ctrl_status().
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Instead of updating the error log page in the caller of the
nvmet_alloc_ctrt() update the error log page in the nvmet_alloc_ctrl().
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
In the function nvmet_alloc_ctrl() we assign status value before we
call nvmet_fine_get_subsys() to:
status = NVME_SC_CONNECT_INVALID_PARAM | NVME_SC_DNR;
After we successfully find the subsystem we again set the status value
to:
status = NVME_SC_CONNECT_INVALID_PARAM | NVME_SC_DNR;
Remove the duplicate status assignment value.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Get rid of a local variable that is not needed and just return the
status directly.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
The barriers were added to the nvme_irq() in commit 3a7afd8ee4
("nvme-pci: remove the CQ lock for interrupt driven queues") to prevent
compiler from doing memory optimization for the variabes that were
protected previously by spinlock in nvme_irq() at completion queue
processing and with queue head check condition.
The variable nvmeq->last_cq_head from those checks was removed in the
commit f6c4d97b0d ("nvme/pci: Remove last_cq_head") that was not
allwing poll queues from mistakenly triggering the spurious interrupt
detection.
Remove the barriers which were protecting the updates to the variables.
Reported-by: Heiner Kallweit <hkallweit1@gmail.com>
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Reviewed-by: Heiner Kallweit <hkallweit1@gmail.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
When data digest is enabled we should unmap pdu iovec before handling
the data digest pdu.
Signed-off-by: Elad Grupi <elad.grupi@dell.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
From the base spec, Figure 78:
"Controller Configuration, these fields are defined as parameters to
configure an "I/O Controller (IOC)" and not to configure a "Discovery
Controller (DC).
...
If the controller does not support I/O queues, then this field shall
be read-only with a value of 0h
Just perform this check for I/O controllers.
Fixes: a07b4970f4 ("nvmet: add a generic NVMe target")
Reported-by: Belanger, Martin <Martin.Belanger@dell.com>
Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
We only setup io queues for nvme controllers, and it makes absolutely no
sense to allow a controller (re)connect without any I/O queues. If we
happen to fail setting the queue count for any reason, we should not allow
this to be a successful reconnect as I/O has no chance in going through.
Instead just fail and schedule another reconnect.
Reported-by: Chao Leng <lengchao@huawei.com>
Fixes: 7110230719 ("nvme-rdma: add a NVMe over Fabrics RDMA host driver")
Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: Chao Leng <lengchao@huawei.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
We only setup io queues for nvme controllers, and it makes absolutely no
sense to allow a controller (re)connect without any I/O queues. If we
happen to fail setting the queue count for any reason, we should not
allow this to be a successful reconnect as I/O has no chance in going
through. Instead just fail and schedule another reconnect.
Fixes: 3f2304f8c6 ("nvme-tcp: add NVMe over TCP host driver")
Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
For our pure advisory use-case, we only rely on this call as a hint, so
fix the warning complaints of using the smp_processor_id variants with
preemption enabled.
Fixes: db5ad6b7f8 ("nvme-tcp: try to send request in queue_rq context")
Fixes: ada8317721 ("nvme-tcp: Fix warning with CONFIG_DEBUG_PREEMPT")
Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Tested-by: Yi Zhang <yi.zhang@redhat.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
When the controller sends us a 0-length r2t PDU we should not attempt to
try to set up a h2cdata PDU but rather conclude that this is a buggy
controller (forward progress is not possible) and simply fail it
immediately.
Fixes: 3f2304f8c6 ("nvme-tcp: add NVMe over TCP host driver")
Reported-by: Belanger, Martin <Martin.Belanger@dell.com>
Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
We voluntarily limit the Write Zeroes sizes to the MDTS value provided by
the hardware, but currently get the units wrong, so fix that.
Fixes: 6e02318eae ("nvme: add support for the Write Zeroes command")
Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Tested-by: Klaus Jensen <k.jensen@samsung.com>
Reviewed-by: Klaus Jensen <k.jensen@samsung.com>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Reviewed-by: Himanshu Madhani <himanshu.madhani@oracle.com>
To avoid an error recovery deadlock where the keep alive work is waiting
for a request and thus can't be flushed to make progress for tearing down
the controller. Also print the error code returned from
blk_mq_alloc_request to help debugging any future issues in this code.
Based on an earlier patch from Hannes Reinecke <hare@suse.de>.
Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Reviewed-by: Hannes Reinecke <hare@suse.de>
Reviewed-by: Daniel Wagner <dwagner@suse.de>
Merge nvme_keep_alive into its only caller to prepare for additional
changes to this code.
Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Reviewed-by: Hannes Reinecke <hare@suse.de>
Reviewed-by: Daniel Wagner <dwagner@suse.de>
Fabrics drivers currently reserve two tags on the admin queue. But
given that the connect command is only run on a freshly created queue
or after all commands have been force aborted we only need to reserve
a single tag.
Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Reviewed-by: Hannes Reinecke <hare@suse.de>
Reviewed-by: Daniel Wagner <dwagner@suse.de>
ns can be NULL at this point, and my move of the check from
the original patch by Chaitanya broke this.
Fixes: 0ec84df495 ("nvme-core: check ctrl css before setting up zns")
Signed-off-by: Christoph Hellwig <hch@lst.de>
Signed-off-by: Jens Axboe <axboe@kernel.dk>
- one more quirk (Dmitry Monakhov)
- fix max_zone_append_sectors initialization (Chaitanya Kulkarni)
- nvme-fc reset/create race fix (James Smart)
- fix status code on aborts/resets (Hannes Reinecke)
- fix the CSS check for ZNS namespaces (Chaitanya Kulkarni)
- fix a use after free in a debug printk in nvme-rdma (Lv Yunlong)
-----BEGIN PGP SIGNATURE-----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=LkdO
-----END PGP SIGNATURE-----
Merge tag 'nvme-5.12-2021-03-12' of git://git.infradead.org/nvme into block-5.12
Pull NVMe fixes from Christoph:
"nvme fixes for 5.12:
- one more quirk (Dmitry Monakhov)
- fix max_zone_append_sectors initialization (Chaitanya Kulkarni)
- nvme-fc reset/create race fix (James Smart)
- fix status code on aborts/resets (Hannes Reinecke)
- fix the CSS check for ZNS namespaces (Chaitanya Kulkarni)
- fix a use after free in a debug printk in nvme-rdma (Lv Yunlong)"
* tag 'nvme-5.12-2021-03-12' of git://git.infradead.org/nvme:
nvme-pci: add the DISABLE_WRITE_ZEROES quirk for a Samsung PM1725a
nvme-rdma: Fix a use after free in nvmet_rdma_write_data_done
nvme-core: check ctrl css before setting up zns
nvme-fc: fix racing controller reset and create association
nvme-fc: return NVME_SC_HOST_ABORTED_CMD when a command has been aborted
nvme-fc: set NVME_REQ_CANCELLED in nvme_fc_terminate_exchange()
nvme: add NVME_REQ_CANCELLED flag in nvme_cancel_request()
nvme: simplify error logic in nvme_validate_ns()
nvme: set max_zone_append_sectors nvme_revalidate_zones
Ever since the addition of multipage bio_vecs BIO_MAX_PAGES has been
horribly confusingly misnamed. Rename it to BIO_MAX_VECS to stop
confusing users of the bio API.
Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Matthew Wilcox (Oracle) <willy@infradead.org>
Reviewed-by: Martin K. Petersen <martin.petersen@oracle.com>
Link: https://lore.kernel.org/r/20210311110137.1132391-2-hch@lst.de
Signed-off-by: Jens Axboe <axboe@kernel.dk>
In nvmet_rdma_write_data_done, rsp is recoverd by wc->wr_cqe and freed by
nvmet_rdma_release_rsp(). But after that, pr_info() used the freed
chunk's member object and could leak the freed chunk address with
wc->wr_cqe by computing the offset.
Signed-off-by: Lv Yunlong <lyl2019@mail.ustc.edu.cn>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Ensure multiple Command Sets are supported before starting to setup a
ZNS namespace.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
[hch: move the check around a bit]
Signed-off-by: Christoph Hellwig <hch@lst.de>
Recent patch to prevent calling __nvme_fc_abort_outstanding_ios in
interrupt context results in a possible race condition. A controller
reset results in errored io completions, which schedules error
work. The change of error work to a work element allows it to fire
after the ctrl state transition to NVME_CTRL_CONNECTING, causing
any outstanding io (used to initialize the controller) to fail and
cause problems for connect_work.
Add a state check to only schedule error work if not in the RESETTING
state.
Fixes: 19fce0470f ("nvme-fc: avoid calling _nvme_fc_abort_outstanding_ios from interrupt context")
Signed-off-by: Nigel Kirkland <nkirkland2304@gmail.com>
Signed-off-by: James Smart <jsmart2021@gmail.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
When a command has been aborted we should return NVME_SC_HOST_ABORTED_CMD
to be consistent with the other transports.
Signed-off-by: Hannes Reinecke <hare@suse.de>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: James Smart <jsmart2021@gmail.com>
Reviewed-by: Daniel Wagner <dwagner@suse.de>
Signed-off-by: Christoph Hellwig <hch@lst.de>
nvme_fc_terminate_exchange() is being called when exchanges are
being deleted, and as such we should be setting the NVME_REQ_CANCELLED
flag to have identical behaviour on all transports.
Signed-off-by: Hannes Reinecke <hare@suse.de>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: James Smart <jsmart2021@gmail.com>
Reviewed-by: Daniel Wagner <dwagner@suse.de>
Signed-off-by: Christoph Hellwig <hch@lst.de>
NVME_REQ_CANCELLED is translated into -EINTR in nvme_submit_sync_cmd(),
so we should be setting this flags during nvme_cancel_request() to
ensure that the callers to nvme_submit_sync_cmd() will get the correct
error code when the controller is reset.
Signed-off-by: Hannes Reinecke <hare@suse.de>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: Chao Leng <lengchao@huawei.com>
Reviewed-by: Daniel Wagner <dwagner@suse.de>
Signed-off-by: Christoph Hellwig <hch@lst.de>
We only should remove namespaces when we get fatal error back from
the device or when the namespace IDs have changed.
So instead of painfully masking out error numbers which might indicate
that the error should be ignored we could use an NVME status code
to indicated when the namespace should be removed.
That simplifies the final logic and makes it less error-prone.
Signed-off-by: Hannes Reinecke <hare@suse.de>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: Daniel Wagner <dwagner@suse.de>
Signed-off-by: Christoph Hellwig <hch@lst.de>
In case we have already established connection to nvmf target, it
shouldn't be allowed to change the model_number. E.g. if someone will
identify ctrl and get model_number of "my_model" later on will change
the model_numbel via configfs to "my_new_model" this will break the NVMe
specification for "Get Log Page – Persistent Event Log" that refers to
Model Number as: "This field contains the same value as reported in the
Model Number field of the Identify Controller data structure, bytes
63:24."
Although it doesn't mentioned explicitly that this field can't be
changed, we can assume it.
So allow setting this field only once: using configfs or in the first
identify ctrl operation.
Signed-off-by: Max Gurtovoy <mgurtovoy@nvidia.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Currently kato is initialized to NVME_DEFAULT_KATO for both
discovery & i/o controllers. This is a problem specifically
for non-persistent discovery controllers since it always ends
up with a non-zero kato value. Fix this by initializing kato
to zero instead, and ensuring various controllers are assigned
appropriate kato values as follows:
non-persistent controllers - kato set to zero
persistent controllers - kato set to NVMF_DEV_DISC_TMO
(or any positive int via nvme-cli)
i/o controllers - kato set to NVME_DEFAULT_KATO
(or any positive int via nvme-cli)
Signed-off-by: Martin George <marting@netapp.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
The hwmon pointer wont be NULL if the registration fails. Though the
exit code path will assign it to ctrl->hwmon_device. Later
nvme_hwmon_exit() will try to free the invalid pointer. Avoid this by
returning the error code from hwmon_device_register_with_info().
Fixes: ed7770f662 ("nvme/hwmon: rework to avoid devm allocation")
Signed-off-by: Daniel Wagner <dwagner@suse.de>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Add the NVME_QUIRK_NO_NS_DESC_LIST and NVME_QUIRK_IGNORE_DEV_SUBNQN
quirks for this buggy device.
Reported and tested in https://bugs.mageia.org/show_bug.cgi?id=28417
Signed-off-by: Pascal Terjan <pterjan@google.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
My 2TB SKC2000 showed the exact same symptoms that were provided
in 538e4a8c57 ("nvme-pci: avoid the deepest sleep state on
Kingston A2000 SSDs"), i.e. a complete NVME lockup that needed
cold boot to get it back.
According to some sources, the A2000 is simply a rebadged
SKC2000 with a slightly optimized firmware.
Adding the SKC2000 PCI ID to the quirk list with the same workaround
as the A2000 made my laptop survive a 5 hours long Yocto bootstrap
buildfest which reliably triggered the SSD lockup previously.
Signed-off-by: Zoltán Böszörményi <zboszor@gmail.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
-----BEGIN PGP SIGNATURE-----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=ccMs
-----END PGP SIGNATURE-----
Merge tag 'block-5.12-2021-02-27' of git://git.kernel.dk/linux-block
Pull more block updates from Jens Axboe:
"A few stragglers (and one due to me missing it originally), and fixes
for changes in this merge window mostly. In particular:
- blktrace cleanups (Chaitanya, Greg)
- Kill dead blk_pm_* functions (Bart)
- Fixes for the bio alloc changes (Christoph)
- Fix for the partition changes (Christoph, Ming)
- Fix for turning off iopoll with polled IO inflight (Jeffle)
- nbd disconnect fix (Josef)
- loop fsync error fix (Mauricio)
- kyber update depth fix (Yang)
- max_sectors alignment fix (Mikulas)
- Add bio_max_segs helper (Matthew)"
* tag 'block-5.12-2021-02-27' of git://git.kernel.dk/linux-block: (21 commits)
block: Add bio_max_segs
blktrace: fix documentation for blk_fill_rw()
block: memory allocations in bounce_clone_bio must not fail
block: remove the gfp_mask argument to bounce_clone_bio
block: fix bounce_clone_bio for passthrough bios
block-crypto-fallback: use a bio_set for splitting bios
block: fix logging on capacity change
blk-settings: align max_sectors on "logical_block_size" boundary
block: reopen the device in blkdev_reread_part
block: don't skip empty device in in disk_uevent
blktrace: remove debugfs file dentries from struct blk_trace
nbd: handle device refs for DESTROY_ON_DISCONNECT properly
kyber: introduce kyber_depth_updated()
loop: fix I/O error on fsync() in detached loop devices
block: fix potential IO hang when turning off io_poll
block: get rid of the trace rq insert wrapper
blktrace: fix blk_rq_merge documentation
blktrace: fix blk_rq_issue documentation
blktrace: add blk_fill_rwbs documentation comment
block: remove superfluous param in blk_fill_rwbs()
...
It's often inconvenient to use BIO_MAX_PAGES due to min() requiring the
sign to be the same. Introduce bio_max_segs() and change BIO_MAX_PAGES to
be unsigned to make it easier for the users.
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Matthew Wilcox (Oracle) <willy@infradead.org>
Signed-off-by: Jens Axboe <axboe@kernel.dk>
Pull swiotlb updates from Konrad Rzeszutek Wilk:
"Two memory encryption related patches (SWIOTLB is enabled by default
for AMD-SEV):
- Add support for alignment so that NVME can properly work
- Keep track of requested DMA buffers length, as underlaying hardware
devices can trip SWIOTLB to bounce too much and crash the kernel
And a tiny fix to use proper APIs in drivers"
* 'stable/for-linus-5.12' of git://git.kernel.org/pub/scm/linux/kernel/git/konrad/swiotlb:
swiotlb: Validate bounce size in the sync/unmap path
nvme-pci: set min_align_mask
swiotlb: respect min_align_mask
swiotlb: don't modify orig_addr in swiotlb_tbl_sync_single
swiotlb: refactor swiotlb_tbl_map_single
swiotlb: clean up swiotlb_tbl_unmap_single
swiotlb: factor out a nr_slots helper
swiotlb: factor out an io_tlb_offset helper
swiotlb: add a IO_TLB_SIZE define
driver core: add a min_align_mask field to struct device_dma_parameters
sdhci: stop poking into swiotlb internals
The PRP addressing scheme requires all PRP entries except for the
first one to have a zero offset into the NVMe controller pages (which
can be different from the Linux PAGE_SIZE). Use the min_align_mask
device parameter to ensure that swiotlb does not change the address
of the buffer modulo the device page size to ensure that the PRPs
won't be malformed.
Signed-off-by: Jianxiong Gao <jxgao@google.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Tested-by: Jianxiong Gao <jxgao@google.com>
Signed-off-by: Konrad Rzeszutek Wilk <konrad.wilk@oracle.com>
-----BEGIN PGP SIGNATURE-----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=vx6U
-----END PGP SIGNATURE-----
Merge tag 'for-5.12/drivers-2021-02-17' of git://git.kernel.dk/linux-block
Pull block driver updates from Jens Axboe:
- Remove the skd driver. It's been EOL for a long time (Damien)
- NVMe pull requests
- fix multipath handling of ->queue_rq errors (Chao Leng)
- nvmet cleanups (Chaitanya Kulkarni)
- add a quirk for buggy Amazon controller (Filippo Sironi)
- avoid devm allocations in nvme-hwmon that don't interact well
with fabrics (Hannes Reinecke)
- sysfs cleanups (Jiapeng Chong)
- fix nr_zones for multipath (Keith Busch)
- nvme-tcp crash fix for no-data commands (Sagi Grimberg)
- nvmet-tcp fixes (Sagi Grimberg)
- add a missing __rcu annotation (Christoph)
- failed reconnect fixes (Chao Leng)
- various tracing improvements (Michal Krakowiak, Johannes
Thumshirn)
- switch the nvmet-fc assoc_list to use RCU protection (Leonid
Ravich)
- resync the status codes with the latest spec (Max Gurtovoy)
- minor nvme-tcp improvements (Sagi Grimberg)
- various cleanups (Rikard Falkeborn, Minwoo Im, Chaitanya
Kulkarni, Israel Rukshin)
- Floppy O_NDELAY fix (Denis)
- MD pull request
- raid5 chunk_sectors fix (Guoqing)
- Use lore links (Kees)
- Use DEFINE_SHOW_ATTRIBUTE for nbd (Liao)
- loop lock scaling (Pavel)
- mtip32xx PCI fixes (Bjorn)
- bcache fixes (Kai, Dongdong)
- Misc fixes (Tian, Yang, Guoqing, Joe, Andy)
* tag 'for-5.12/drivers-2021-02-17' of git://git.kernel.dk/linux-block: (64 commits)
lightnvm: pblk: Replace guid_copy() with export_guid()/import_guid()
lightnvm: fix unnecessary NULL check warnings
nvme-tcp: fix crash triggered with a dataless request submission
block: Replace lkml.org links with lore
nbd: Convert to DEFINE_SHOW_ATTRIBUTE
nvme: add 48-bit DMA address quirk for Amazon NVMe controllers
nvme-hwmon: rework to avoid devm allocation
nvmet: remove else at the end of the function
nvmet: add nvmet_req_subsys() helper
nvmet: use min of device_path and disk len
nvmet: use invalid cmd opcode helper
nvmet: use invalid cmd opcode helper
nvmet: add helper to report invalid opcode
nvmet: remove extra variable in id-ns handler
nvmet: make nvmet_find_namespace() req based
nvmet: return uniform error for invalid ns
nvmet: set status to 0 in case for invalid nsid
nvmet-fc: add a missing __rcu annotation to nvmet_fc_tgt_assoc.queues
nvme-multipath: set nr_zones for zoned namespaces
nvmet-tcp: fix potential race of tcp socket closing accept_work
...
-----BEGIN PGP SIGNATURE-----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=os1E
-----END PGP SIGNATURE-----
Merge tag 'for-5.12/block-2021-02-17' of git://git.kernel.dk/linux-block
Pull core block updates from Jens Axboe:
"Another nice round of removing more code than what is added, mostly
due to Christoph's relentless pursuit of tech debt removal/cleanups.
This pull request contains:
- Two series of BFQ improvements (Paolo, Jan, Jia)
- Block iov_iter improvements (Pavel)
- bsg error path fix (Pan)
- blk-mq scheduler improvements (Jan)
- -EBUSY discard fix (Jan)
- bvec allocation improvements (Ming, Christoph)
- bio allocation and init improvements (Christoph)
- Store bdev pointer in bio instead of gendisk + partno (Christoph)
- Block trace point cleanups (Christoph)
- hard read-only vs read-only split (Christoph)
- Block based swap cleanups (Christoph)
- Zoned write granularity support (Damien)
- Various fixes/tweaks (Chunguang, Guoqing, Lei, Lukas, Huhai)"
* tag 'for-5.12/block-2021-02-17' of git://git.kernel.dk/linux-block: (104 commits)
mm: simplify swapdev_block
sd_zbc: clear zone resources for non-zoned case
block: introduce blk_queue_clear_zone_settings()
zonefs: use zone write granularity as block size
block: introduce zone_write_granularity limit
block: use blk_queue_set_zoned in add_partition()
nullb: use blk_queue_set_zoned() to setup zoned devices
nvme: cleanup zone information initialization
block: document zone_append_max_bytes attribute
block: use bi_max_vecs to find the bvec pool
md/raid10: remove dead code in reshape_request
block: mark the bio as cloned in bio_iov_bvec_set
block: set BIO_NO_PAGE_REF in bio_iov_bvec_set
block: remove a layer of indentation in bio_iov_iter_get_pages
block: turn the nr_iovecs argument to bio_alloc* into an unsigned short
block: remove the 1 and 4 vec bvec_slabs entries
block: streamline bvec_alloc
block: factor out a bvec_alloc_gfp helper
block: move struct biovec_slab to bio.c
block: reuse BIO_INLINE_VECS for integrity bvecs
...
Some Amazon NVMe controllers do not follow the NVMe specification
and are limited to 48-bit DMA addresses. Add a quirk to force
bounce buffering if needed and limit the IOVA allocation for these
devices.
This affects all current Amazon NVMe controllers that expose EBS
volumes (0x0061, 0x0065, 0x8061) and local instance storage
(0xcd00, 0xcd01, 0xcd02).
Signed-off-by: Filippo Sironi <sironi@amazon.de>
Signed-off-by: Christoph Hellwig <hch@lst.de>
The original design to use device-managed resource allocation
doesn't really work as the NVMe controller has a vastly different
lifetime than the hwmon sysfs attributes, causing warning about
duplicate sysfs entries upon reconnection.
This patch reworks the hwmon allocation to avoid device-managed
resource allocation, and uses the NVMe controller as parent for
the sysfs attributes.
Cc: Guenter Roeck <linux@roeck-us.net>
Signed-off-by: Hannes Reinecke <hare@suse.de>
Tested-by: Enzo Matsumiya <ematsumiya@suse.de>
Tested-by: Daniel Wagner <dwagner@suse.de>
Signed-off-by: Christoph Hellwig <hch@lst.de>
The function nvmet_parse_io_cmd() returns value from
nvmet_file_parse_io_cmd() or nvmet_bdev_parse_io_cmd() based on which
backend is set for the request. Remove the else and just return the
value from nvmet_bdev_parse_io_cmd().
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Just like what we have to get the passthru ctrl from the req, add an
helper to get the subsystem associated with the nvmet_req() instead
of open coding the chain of structures.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
In function __assign_req_name() instead of using the DEVICE_NAME_LEN in
strncpy() use min of DISK_NAME_LEN and strlen(req->ns->device_path).
This is needed to turn off the following warnings:-
In file included from drivers/nvme/target/core.c:14:
In function ‘__assign_req_name’,
inlined from ‘trace_event_raw_event_nvmet_req_init’ at drivers/nvme/target/./trace.h:58:1:
drivers/nvme/target/trace.h:52:3: warning: ‘strncpy’ specified bound 32 equals destination size [-Wstringop-truncation]
strncpy(name, req->ns->device_path, DISK_NAME_LEN);
^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
In function ‘__assign_req_name’,
inlined from ‘perf_trace_nvmet_req_complete’ at drivers/nvme/target/./trace.h💯1:
drivers/nvme/target/trace.h:52:3: warning: ‘strncpy’ specified bound 32 equals destination size [-Wstringop-truncation]
strncpy(name, req->ns->device_path, DISK_NAME_LEN);
^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
In function ‘__assign_req_name’,
inlined from ‘perf_trace_nvmet_req_init’ at drivers/nvme/target/./trace.h:58:1:
drivers/nvme/target/trace.h:52:3: warning: ‘strncpy’ specified bound 32 equals destination size [-Wstringop-truncation]
strncpy(name, req->ns->device_path, DISK_NAME_LEN);
^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
In function ‘__assign_req_name’,
inlined from ‘trace_event_raw_event_nvmet_req_complete’ at drivers/nvme/target/./trace.h💯1:
drivers/nvme/target/trace.h:52:3: warning: ‘strncpy’ specified bound 32 equals destination size [-Wstringop-truncation]
strncpy(name, req->ns->device_path, DISK_NAME_LEN);
^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
In the NVMeOF block device backend, file backend, and passthru backend
we reject and report the commands if opcode is not handled.
Use the previously introduced helper in the passthru backend to make the
error message uniform.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
In the NVMeOF block device backend, file backend, and passthru backend
we reject and report the commands if opcode is not handled.
Use the previously introduced helper in file backend to reduce the
duplicate code and make the error message uniform.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
In the NVMeOF block device backend, file backend, and passthru backend
we reject and report the commands if opcode is not handled.
Add an helper and use it in block device backend to keep the code
and error message uniform.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
In nvmet_execute_identify_ns() local variable ctrl is accessed only in
one place, remove that and directly use it from nvmet_req->sq->ctrl.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
The six callers of nvmet_find_namespace() duplicate the error log page
update and status setting code for each call on failure.
All callers are nvmet requests based functions, so we can pass req
to the nvmet_find_namesapce() & derive ctrl from req, that'll allow us
to update the error log page in nvmet_find_namespace(). Now that we
pass the request we can also get rid of the local variable in
nvmet_find_namespace() and use the req->ns and return the error code.
Replace the ctrl parameter with nvmet_req for nvmet_find_namespace(),
centralize the error log page update for non allocated namesapces, and
return uniform error for non-allocated namespace.
The nvmet_find_namespace() takes nsid parameter which is from NVMe
commands structures such as get_log_page, identify, rw and common. All
these commands have same offset for the nsid field.
Derive nsid from req->cmd->common.nsid) & remove the extra parameter
from the nvmet_find_namespace().
Lastly now we associate the ns to the req parameter that we pass to the
nvmet_find_namespace(), rename nvmet_find_namespace() to
nvmet_req_find_ns().
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
For nvmet_find_namespace() error case we have inconsistent error code
mapping in the function nvmet_get_smart_log_nsid() and
nvmet_set_feat_write_protect().
There is no point in retrying for the invalid namesapce from the host
side. Set the error code to the NVME_SC_INVALID_NS | NVME_SC_DNR which
matches what we have in nvmet_execute_identify_desclist().
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
For unallocated namespace in nvmet_execute_identify_ns() don't set the
status to NVME_SC_INVALID_NS, set it to zero.
Fixes: bffcd50778 ("nvmet: set right status on error in id-ns handler")
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Make sparse happy after the recent conversion to RCU lookups.
Fixes: 4e2f02bf77 ("nvmet-fc: use RCU proctection for assoc_list")
Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Reviewed-by: James Smart <james.smart@broadcom.com>
The bio based drivers only require the request_queue's nr_zones is set,
so set this field in the head if the namespace path is zoned.
Fixes: 240e6ee272 ("nvme: support for zoned namespaces")
Reported-by: Minwoo Im <minwoo.im.dev@gmail.com>
Cc: Damien Le Moal <damien.lemoal@wdc.com>
Signed-off-by: Keith Busch <kbusch@kernel.org>
Signed-off-by: Christoph Hellwig <hch@lst.de>
When we accept a TCP connection and allocate an nvmet-tcp queue we should
make sure not to fully establish it or reference it as the connection may
be already closing, which triggers queue release work, which does not
fence against queue establishment.
In order to address such a race, we make sure to check the sk_state and
contain the queue reference to be done underneath the sk_callback_lock
such that the queue release work correctly fences against it.
Fixes: 872d26a391 ("nvmet-tcp: add NVMe over TCP target driver")
Reported-by: Elad Grupi <elad.grupi@dell.com>
Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
When a host sends multiple h2cdata PDUs for a single command, we
should verify the data digest calculation per PDU and not
per command.
Fixes: 872d26a391 ("nvmet-tcp: add NVMe over TCP target driver")
Reported-by: Narayan Ayalasomayajula <Narayan.Ayalasomayajula@wdc.com>
Tested-by: Narayan Ayalasomayajula <Narayan.Ayalasomayajula@wdc.com>
Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
nvme_rdma_post_send failing is a path related error and should bounce
to another path when using nvme-multipath. Call nvme_host_path_error
when nvme_rdma_post_send returns -EIO to ensure nvme_complete_rq gets
invoked to fail over to another path if there is one.
Signed-off-by: Chao Leng <lengchao@huawei.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
When reconnecting, the request may be completed with
NVME_SC_HOST_PATH_ERROR in nvmf_fail_nonready_command, which currently
set the state of the request to MQ_RQ_IN_FLIGHT before calling
nvme_complete_rq. When this happens for a request that is freed by
the caller, such as nvme_submit_user_cmd, in the worst case the request
could be completed again in tear down process.
Instead of calling blk_mq_start_request from nvmf_fail_nonready_command,
just use the new nvme_host_path_error helper to complete the command
without starting it.
Signed-off-by: Chao Leng <lengchao@huawei.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
When using nvme native multipathing, if a path related error occurs
during ->queue_rq, the request needs to be completed with
NVME_SC_HOST_PATH_ERROR so that the request can be failed over.
Introduce a helper to complete the command from ->queue_rq in a wait
that invokes nvme_complete_rq.
Signed-off-by: Chao Leng <lengchao@huawei.com>
[hch: renamed, added a return value to clean up the callers a bit]
Signed-off-by: Christoph Hellwig <hch@lst.de>
Fix the following coccicheck warning:
./drivers/nvme/host/core.c:3580:8-16: WARNING: use scnprintf or sprintf.
./drivers/nvme/host/core.c:3570:8-16: WARNING: use scnprintf or sprintf.
./drivers/nvme/host/core.c:3560:8-16: WARNING: use scnprintf or sprintf.
./drivers/nvme/host/core.c:3526:8-16: WARNING: use scnprintf or sprintf.
./drivers/nvme/host/core.c:2833:8-16: WARNING: use scnprintf or sprintf.
Reported-by: Abaci Robot<abaci@linux.alibaba.com>
Signed-off-by: Jiapeng Chong <jiapeng.chong@linux.alibaba.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
For a zoned namespace, in nvme_update_ns_info(), call
nvme_update_zone_info() after executing nvme_update_disk_info() so that
the namespace queue logical and physical block size limits are set.
This allows setting the namespace queue max_zone_append_sectors limit
in nvme_update_zone_info() instead of nvme_revalidate_zones(),
simplifying this function. Also use blk_queue_set_zoned() to set the
namespace zoned model.
Signed-off-by: Damien Le Moal <damien.lemoal@wdc.com>
Reviewed-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Reviewed-by: Johannes Thumshirn <johannes.thumshirn@edc.com>
Signed-off-by: Jens Axboe <axboe@kernel.dk>
When the host sends multiple h2cdata PDUs, we keep track on
the receive progress and calculate the scatterlist index and
offsets.
The issue is that sg_offset should only be kept for the first
iov entry we map in the iovec as this is the difference between
our cursor and the sg entry offset itself.
In addition, the sg index was calculated wrong because we should
not round up when dividing the command byte offset with PAG_SIZE.
Fixes: 872d26a391 ("nvmet-tcp: add NVMe over TCP target driver")
Reported-by: Narayan Ayalasomayajula <Narayan.Ayalasomayajula@wdc.com>
Tested-by: Narayan Ayalasomayajula <Narayan.Ayalasomayajula@wdc.com>
Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Tested both with Corsairs firmware 11.3 and 13.0 for the Corsairs MP600
and both have the issue as reported by the kernel.
nvme nvme0: missing or invalid SUBNQN field.
Signed-off-by: Claus Stovgaard <claus.stovgaard@gmail.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Use nvme_cancel_tagset and nvme_cancel_admin_tagset to clean code for
tear down process.
Signed-off-by: Chao Leng <lengchao@huawei.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Use nvme_cancel_tagset and nvme_cancel_admin_tagset to clean code for
tear down process.
Signed-off-by: Chao Leng <lengchao@huawei.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
If reconnect failed after start io queues, the queues will be unquiesced
and new requests continue to be delivered. Reconnection error handling
process directly free queues without cancel suspend requests. The
suppend request will time out, and then crash due to use the queue
after free.
Add sync queues and cancel suppend requests for reconnection error
handling.
Signed-off-by: Chao Leng <lengchao@huawei.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
A crash happens when inject failed reconnection.
If reconnect failed after start io queues, the queues will be unquiesced
and new requests continue to be delivered. Reconnection error handling
process directly free queues without cancel suspend requests. The
suppend request will time out, and then crash due to use the queue
after free.
Add sync queues and cancel suppend requests for reconnection error
handling.
Signed-off-by: Chao Leng <lengchao@huawei.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Add nvme_cancel_tagset and nvme_cancel_admin_tagset for tear down and
reconnection error handling.
Signed-off-by: Chao Leng <lengchao@huawei.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Remove the extra space in the nvme_free_cels() when calling
xa_for_each loop which is not a common practice
(except drivers/infiniband/core/ not sure why).
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
When support for the NVMe ZNS commands was merged, tracing of these has
been omitted.
Add nvme_cmd_zone_mgmt_send, nvme_cmd_zone_mgmt_recv as well as
nvme_cmd_zone_append to the nvme driver's tracing facility.
Signed-off-by: Johannes Thumshirn <johannes.thumshirn@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Add detailed parsing of format nvm admin command to make the
trace log more consistent and human-readable.
Signed-off-by: Michal Krakowiak <michal.krakowiak@intel.com>
Acked-by: Dan Williams <dan.j.williams@intel.com>
Reviewed-by: Minwoo Im <minwoo.im.dev@gmail.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
In this preparation patch, we add helpers to convert lbas to sectors &
sectors to lba. This is needed to eliminate code duplication in the ZBD
backend.
Use these helpers in the block device backend.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Reviewed-by: Damien Le Moal <damien.lemoal@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
We remove the extra local variable struct nvmet_ns in
nvmet_execute_identify_ns() since req already has ns member that can be
reused, this also eliminates the explicit call to nvmet_put_namespace()
which is already present in the request completion path.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
We remove the extra local variable struct nvmet_ns in
nvmet_execute_identify_desclist() since req already has ns member that
can be reused, this also eliminates the explicit call to
nvmet_put_namespace() which is already present in the request
completion path.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
We remove the extra local variable struct nvmet_ns in
nvmet_get_smart_log_nsid() since req already has ns member that can be
reused, this also eliminates the explicit call to nvmet_put_namespace()
which is already present in the request completion path.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Just for current code in nvme_cleanup_cmd(), we don't have to get
namespace instance, but we need controller instance.
Controller instance can be retrieved by namespace instance, but it can
be directly accessed by nvme_request instance from request.
ctrl = nvme_req(req)->ctrl;
We don't have to go around namespace instance from request instance
through gendisk.
Signed-off-by: Minwoo Im <minwoo.im.dev@gmail.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
iov_iter uses the right helpers so we should be able
to pass in a multipage bvec. Right now the iov_iter is
initialized with more segments that it needs which doesn't
fail because the iov_iter is capped by byte count, but it
is better to use a full multipage bvec iter.
Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
We might set the iov_iter direction wrong, which is harmless for this
use-case, but get it right. Also this makes the code slightly cleaner.
Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
The controller can request a delay retrying a failed command by setting
the Command Retry Delay (CRD) field in the Completion Queue Entry.
Currentlty this features is only applied to commands on the I/O queue, but
not to commands on the admin queue. Retreive the nvme_ctrl from the
request so that no namespace is required and apply the feature to all
commands.
Signed-off-by: Minwoo Im <minwoo.im.dev@gmail.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
The only usage of these is to put their addresses in arrays of pointers
to const attribute_groups. Make them const to allow the compiler to put
them in read-only memory.
Signed-off-by: Rikard Falkeborn <rikard.falkeborn@gmail.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
searching assoc_list protected by rcu_read_lock if list not changed inline.
and according to the rcu list rules.
queue array embedded into nvmet_fc_tgt_assoc protected by rcu_read_lock
according to rcu dereference/assign rules.
queue and assoc object freed after grace period by call_rcu.
tgtport lock taken for changing assoc_list.
Reviewed-by: Eldad Zinger <Eldad.Zinger@dell.com>
Reviewed-by: Elad Grupi <Elad.Grupi@dell.com>
Reviewed-by: James Smart <james.smart@broadcom.com>
Signed-off-by: Leonid Ravich <Leonid.Ravich@emc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Remove extra tab.
Signed-off-by: Israel Rukshin <israelr@nvidia.com>
Reviewed-by: Max Gurtovoy <mgurtovoy@nvidia.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Remove code duplication.
Signed-off-by: Israel Rukshin <israelr@nvidia.com>
Reviewed-by: Max Gurtovoy <mgurtovoy@nvidia.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
The "list" of nvme_ns_head is used as rcu list, now in nvme_init_ns_head
list_add_tail is used to add ns->siblings to the rcu list. It is not safe.
Should use list_add_tail_rcu instead of list_add_tail.
Signed-off-by: Chao Leng <lengchao@huawei.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
nvme_round_robin_path() should test if the return ns pointer is valid.
nvme_next_ns() will return a NULL pointer if there is no path left.
Fixes: 75c10e7327 ("nvme-multipath: round-robin I/O policy")
Signed-off-by: Daniel Wagner <dwagner@suse.de>
Reviewed-by: Hannes Reinecke <hare@suse.de>
Signed-off-by: Christoph Hellwig <hch@lst.de>
There is no point in allocating memory for a synchronous flush.
Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Johannes Thumshirn <johannes.thumshirn@wdc.com>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Acked-by: Damien Le Moal <damien.lemoal@wdc.com>
Signed-off-by: Jens Axboe <axboe@kernel.dk>
Always use the bio_set_dev helper to assign ->bi_bdev to make sure
other state related to the device is uptodate.
Signed-off-by: Christoph Hellwig <hch@lst.de>
Signed-off-by: Jens Axboe <axboe@kernel.dk>
Replace the gendisk pointer in struct bio with a pointer to the newly
improved struct block device. From that the gendisk can be trivially
accessed with an extra indirection, but it also allows to directly
look up all information related to partition remapping.
Signed-off-by: Christoph Hellwig <hch@lst.de>
Acked-by: Tejun Heo <tj@kernel.org>
Signed-off-by: Jens Axboe <axboe@kernel.dk>
Unconditionally call set_disk_ro now that it only updates the hardware
state. This allows to properly set up the Linux devices read-only when
the controller turns a previously writable namespace read-only.
Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Reviewed-by: Martin K. Petersen <martin.petersen@oracle.com>
Reviewed-by: Hannes Reinecke <hare@suse.de>
Signed-off-by: Jens Axboe <axboe@kernel.dk>
Properly unwind step by step using refactored helpers from nvme_unmap_data
to avoid a potential double dma_unmap on a mapping failure.
Fixes: 7fe07d14f7 ("nvme-pci: merge nvme_free_iod into nvme_unmap_data")
Reported-by: Marc Orr <marcorr@google.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Reviewed-by: Marc Orr <marcorr@google.com>
Split out three helpers from nvme_unmap_data that will allow finer grained
unwinding from nvme_map_data.
Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Reviewed-by: Marc Orr <marcorr@google.com>
The function nvmet_execute_identify_ns() doesn't set the status if call
to nvmet_find_namespace() fails. In that case we set the status of the
request to the value return by the nvmet_copy_sgl().
Set the status to NVME_SC_INVALID_NS and adjust the code such that
request will have the right status on nvmet_find_namespace() failure.
Without this patch :-
NVME Identify Namespace 3:
nsze : 0
ncap : 0
nuse : 0
nsfeat : 0
nlbaf : 0
flbas : 0
mc : 0
dpc : 0
dps : 0
nmic : 0
rescap : 0
fpi : 0
dlfeat : 0
nawun : 0
nawupf : 0
nacwu : 0
nabsn : 0
nabo : 0
nabspf : 0
noiob : 0
nvmcap : 0
mssrl : 0
mcl : 0
msrc : 0
nsattr : 0
nvmsetid: 0
anagrpid: 0
endgid : 0
nguid : 00000000000000000000000000000000
eui64 : 0000000000000000
lbaf 0 : ms:0 lbads:0 rp:0 (in use)
With this patch-series :-
feb3b88b501e (HEAD -> nvme-5.11) nvmet: remove extra variable in identify ns
6302aa67210a nvmet: remove extra variable in id-desclist
ed57951da453 nvmet: remove extra variable in smart log nsid
be384b8c24dc nvmet: set right status on error in id-ns handler
NVMe status: INVALID_NS: The namespace or the format of that namespace is invalid(0xb)
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Since NVMe v1.4 the Controller Memory Buffer must be explicitly enabled
by the host.
Signed-off-by: Klaus Jensen <k.jensen@samsung.com>
[hch: avoid a local variable and add a comment]
Signed-off-by: Christoph Hellwig <hch@lst.de>
Each name space has a request queue, if complete request long time,
multi request queues may have time out requests at the same time,
nvme_tcp_timeout will execute concurrently. Multi requests in different
request queues may be queued in the same tcp queue, multi
nvme_tcp_timeout may call nvme_tcp_stop_queue at the same time.
The first nvme_tcp_stop_queue will clear NVME_TCP_Q_LIVE and continue
stopping the tcp queue(cancel io_work), but the others check
NVME_TCP_Q_LIVE is already cleared, and then directly complete the
requests, complete request before the io work is completely canceled may
lead to a use-after-free condition.
Add a multex lock to serialize nvme_tcp_stop_queue.
Signed-off-by: Chao Leng <lengchao@huawei.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
A crash happens when inject completing request long time(nearly 30s).
Each name space has a request queue, when inject completing request long
time, multi request queues may have time out requests at the same time,
nvme_rdma_timeout will execute concurrently. Multi requests in different
request queues may be queued in the same rdma queue, multi
nvme_rdma_timeout may call nvme_rdma_stop_queue at the same time.
The first nvme_rdma_timeout will clear NVME_RDMA_Q_LIVE and continue
stopping the rdma queue(drain qp), but the others check NVME_RDMA_Q_LIVE
is already cleared, and then directly complete the requests, complete
request before the qp is fully drained may lead to a use-after-free
condition.
Add a multex lock to serialize nvme_rdma_stop_queue.
Signed-off-by: Chao Leng <lengchao@huawei.com>
Tested-by: Israel Rukshin <israelr@nvidia.com>
Reviewed-by: Israel Rukshin <israelr@nvidia.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
According to NVMe spec v1.4, section 8.3.1, the PRINFO bit and
the metadata size play a vital role in deteriming the host buffer size.
If PRIFNO bit is set and MS==8, the host doesn't add the metadata buffer,
instead the controller adds it.
Signed-off-by: Revanth Rajashekar <revanth.rajashekar@intel.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Discovery controllers usually don't support smart log page command.
So when we connect to the discovery controller we see this warning:
nvme nvme0: Failed to read smart log (error 24577)
nvme nvme0: new ctrl: NQN "nqn.2014-08.org.nvmexpress.discovery", addr 192.168.123.1:8009
nvme nvme0: Removing ctrl: NQN "nqn.2014-08.org.nvmexpress.discovery"
Introduce a new helper to understand if the controller is a discovery
controller and use this helper to skip nvme_init_hwmon (also use it in
other places that we check if the controller is a discovery controller).
Fixes: 400b6a7b13 ("nvme: Add hardware monitoring support")
Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
When a bio merges, we can get a request that spans multiple
bios, and the overall request payload size is the sum of
all bios. When we calculate how much we need to send
from the existing bio (and bvec), we did not take into
account the iov_iter byte count cap.
Since multipage bvecs support, bvecs can split in the middle
which means that when we account for the last bvec send we
should also take the iov_iter byte count cap as it might be
lower than the last bvec size.
Reported-by: Hao Wang <pkuwangh@gmail.com>
Fixes: 3f2304f8c6 ("nvme-tcp: add NVMe over TCP host driver")
Tested-by: Hao Wang <pkuwangh@gmail.com>
Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
We shouldn't call smp_processor_id() in a preemptible
context, but this is advisory at best, so instead
call __smp_processor_id().
Fixes: db5ad6b7f8 ("nvme-tcp: try to send request in queue_rq context")
Reported-by: Or Gerlitz <gerlitz.or@gmail.com>
Reported-by: Yi Zhang <yi.zhang@redhat.com>
Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
When setting port traddr to INADDR_ANY, the listening cm_id->device
is NULL. The associate IB device is known only when a connect request
event arrives, so checking T10-PI device capability should be done
at this stage.
Fixes: b09160c399 ("nvmet-rdma: add metadata/T10-PI support")
Signed-off-by: Israel Rukshin <israelr@nvidia.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: Max Gurtovoy <mgurtovoy@nvidia.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
The only used argument in this function is the "req".
Signed-off-by: Max Gurtovoy <mgurtovoy@nvidia.com>
Reviewed-by: Minwoo Im <minwoo.im.dev@gmail.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
When a queue is in NVMET_RDMA_Q_CONNECTING state, it may has some
requests at rsp_wait_list. In case a disconnect occurs at this
state, no one will empty this list and will return the requests to
free_rsps list. Normally nvmet_rdma_queue_established() free those
requests after moving the queue to NVMET_RDMA_Q_LIVE state, but in
this case __nvmet_rdma_queue_disconnect() is called before. The
crash happens at nvmet_rdma_free_rsps() when calling
list_del(&rsp->free_list), because the request exists only at
the wait list. To fix the issue, simply clear rsp_wait_list when
destroying the queue.
Signed-off-by: Israel Rukshin <israelr@nvidia.com>
Reviewed-by: Max Gurtovoy <mgurtovoy@nvidia.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
There are no callers for nvme_reset_ctrl_sync() and
nvme_alloc_request_qid() so that we keep the symbols exported.
Unexport those functions, mark them static and update the header file
respectively.
Signed-off-by: Minwoo Im <minwoo.im.dev@gmail.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
While handling the completion queue, keep a local copy of the command id
from the DMA-accessible completion entry. This silences a time-of-check
to time-of-use (TOCTOU) warning from KF/x[1], with respect to a
Thunderclap[2] vulnerability analysis. The double-read impact appears
benign.
There may be a theoretical window for @command_id to be used as an
adversary-controlled array-index-value for mounting a speculative
execution attack, but that mitigation is saved for a potential follow-on.
A man-in-the-middle attack on the data payload is out of scope for this
analysis and is hopefully mitigated by filesystem integrity mechanisms.
[1] https://github.com/intel/kernel-fuzzer-for-xen-project
[2] http://thunderclap.io/thunderclap-paper-ndss2019.pdf
Signed-off-by: Lalithambika Krishna Kumar <lalithambika.krishnakumar@intel.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
We may send a request (with or without its data) from two paths:
1. From our I/O context nvme_tcp_io_work which is triggered from:
- queue_rq
- r2t reception
- socket data_ready and write_space callbacks
2. Directly from queue_rq if the send_list is empty (because we want to
save the context switch associated with scheduling our io_work).
However, given that now we have the send_mutex, we may run into a race
condition where none of these contexts will send the pending payload to
the controller. Both io_work send path and queue_rq send path
opportunistically attempt to acquire the send_mutex however queue_rq only
attempts to send a single request, and if io_work context fails to
acquire the send_mutex it will complete without rescheduling itself.
The race can trigger with the following sequence:
1. queue_rq sends request (no incapsule data) and blocks
2. RX path receives r2t - prepares data PDU to send, adds h2cdata PDU
to the send_list and schedules io_work
3. io_work triggers and cannot acquire the send_mutex - because of (1),
ends without self rescheduling
4. queue_rq completes the send, and completes
==> no context will send the h2cdata - timeout.
Fix this by having queue_rq sending as much as it can from the send_list
such that if it still has any left, its because the socket buffer is
full and the socket write_space callback will trigger, thus guaranteeing
that a context will be scheduled to send the h2cdata PDU.
Fixes: db5ad6b7f8 ("nvme-tcp: try to send request in queue_rq context")
Reported-by: Potnuri Bharat Teja <bharat@chelsio.com>
Reported-by: Samuel Jones <sjones@kalrayinc.com>
Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
Tested-by: Potnuri Bharat Teja <bharat@chelsio.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
A system with more than one of these SSDs will only have one usable.
Hence the kernel fails to detect nvme devices due to duplicate cntlids.
[ 6.274554] nvme nvme1: Duplicate cntlid 33 with nvme0, rejecting
[ 6.274566] nvme nvme1: Removing after probe failure status: -22
Adding the NVME_QUIRK_IGNORE_DEV_SUBNQN quirk to resolves the issue.
Signed-off-by: Gopal Tiwari <gtiwari@redhat.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Kernel robot had the following warnings:
>> fcloop.c:1506:6: warning: %x in format string (no. 1) requires
>> 'unsigned int *' but the argument type is 'signed int *'.
>> [invalidScanfArgType_int]
>> if (sscanf(buf, "%x:%d:%d", &opcode, &starting, &amount) != 3)
>> ^
Resolve by changing opcode from and int to an unsigned int
and
>> fcloop.c:1632:32: warning: Uninitialized variable: lport [uninitvar]
>> ret = __wait_localport_unreg(lport);
>> ^
>> fcloop.c:1615:28: warning: Uninitialized variable: nport [uninitvar]
>> ret = __remoteport_unreg(nport, rport);
>> ^
These aren't actual issues as the values are assigned prior to use.
It appears the tool doesn't understand list_first_entry_or_null().
Regardless, quiet the tool by initializing the pointers to NULL at
declaration.
Signed-off-by: James Smart <james.smart@broadcom.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Recent patches changed calling sequences. nvme_fc_abort_outstanding_ios
used to be called from a timeout or work context. Now it is being called
in an io completion context, which can be an interrupt handler.
Unfortunately, the abort outstanding ios routine attempts to stop nvme
queues and nested routines that may try to sleep, which is in conflict
with the interrupt handler.
Correct replacing the direct call with a work element scheduling, and the
abort outstanding ios routine will be called in the work element.
Fixes: 95ced8a2c7 ("nvme-fc: eliminate terminate_io use by nvme_fc_error_recovery")
Signed-off-by: James Smart <james.smart@broadcom.com>
Reported-by: Daniel Wagner <dwagner@suse.de>
Tested-by: Daniel Wagner <dwagner@suse.de>
Signed-off-by: Christoph Hellwig <hch@lst.de>
A smaller set of patches, nothing stands out as being particularly major
this cycle:
- Driver bug fixes and updates: bnxt_re, cxgb4, rxe, hns, i40iw, cxgb4,
mlx4 and mlx5
- Bug fixes and polishing for the new rts ULP
- Cleanup of uverbs checking for allowed driver operations
- Use sysfs_emit all over the place
- Lots of bug fixes and clarity improvements for hns
- hip09 support for hns
- NDR and 50/100Gb signaling rates
- Remove dma_virt_ops and go back to using the IB DMA wrappers
- mlx5 optimizations for contiguous DMA regions
-----BEGIN PGP SIGNATURE-----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=9t8b
-----END PGP SIGNATURE-----
Merge tag 'for-linus' of git://git.kernel.org/pub/scm/linux/kernel/git/rdma/rdma
Pull rdma updates from Jason Gunthorpe:
"A smaller set of patches, nothing stands out as being particularly
major this cycle. The biggest item would be the new HIP09 HW support
from HNS, otherwise it was pretty quiet for new work here:
- Driver bug fixes and updates: bnxt_re, cxgb4, rxe, hns, i40iw,
cxgb4, mlx4 and mlx5
- Bug fixes and polishing for the new rts ULP
- Cleanup of uverbs checking for allowed driver operations
- Use sysfs_emit all over the place
- Lots of bug fixes and clarity improvements for hns
- hip09 support for hns
- NDR and 50/100Gb signaling rates
- Remove dma_virt_ops and go back to using the IB DMA wrappers
- mlx5 optimizations for contiguous DMA regions"
* tag 'for-linus' of git://git.kernel.org/pub/scm/linux/kernel/git/rdma/rdma: (147 commits)
RDMA/cma: Don't overwrite sgid_attr after device is released
RDMA/mlx5: Fix MR cache memory leak
RDMA/rxe: Use acquire/release for memory ordering
RDMA/hns: Simplify AEQE process for different types of queue
RDMA/hns: Fix inaccurate prints
RDMA/hns: Fix incorrect symbol types
RDMA/hns: Clear redundant variable initialization
RDMA/hns: Fix coding style issues
RDMA/hns: Remove unnecessary access right set during INIT2INIT
RDMA/hns: WARN_ON if get a reserved sl from users
RDMA/hns: Avoid filling sl in high 3 bits of vlan_id
RDMA/hns: Do shift on traffic class when using RoCEv2
RDMA/hns: Normalization the judgment of some features
RDMA/hns: Limit the length of data copied between kernel and userspace
RDMA/mlx4: Remove bogus dev_base_lock usage
RDMA/uverbs: Fix incorrect variable type
RDMA/core: Do not indicate device ready when device enablement fails
RDMA/core: Clean up cq pool mechanism
RDMA/core: Update kernel documentation for ib_create_named_qp()
MAINTAINERS: SOFT-ROCE: Change Zhu Yanjun's email address
...
-----BEGIN PGP SIGNATURE-----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=ayp2
-----END PGP SIGNATURE-----
Merge tag 'for-5.11/drivers-2020-12-14' of git://git.kernel.dk/linux-block
Pull block driver updates from Jens Axboe:
"Nothing major in here:
- NVMe pull request from Christoph:
- nvmet passthrough improvements (Chaitanya Kulkarni)
- fcloop error injection support (James Smart)
- read-only support for zoned namespaces without Zone Append
(Javier González)
- improve some error message (Minwoo Im)
- reject I/O to offline fabrics namespaces (Victor Gladkov)
- PCI queue allocation cleanups (Niklas Schnelle)
- remove an unused allocation in nvmet (Amit Engel)
- a Kconfig spelling fix (Colin Ian King)
- nvme_req_qid simplication (Baolin Wang)
- MD pull request from Song:
- Fix race condition in md_ioctl() (Dae R. Jeong)
- Initialize read_slot properly for raid10 (Kevin Vigor)
- Code cleanup (Pankaj Gupta)
- md-cluster resync/reshape fix (Zhao Heming)
- Move null_blk into its own directory (Damien Le Moal)
- null_blk zone and discard improvements (Damien Le Moal)
- bcache race fix (Dongsheng Yang)
- Set of rnbd fixes/improvements (Gioh Kim, Guoqing Jiang, Jack Wang,
Lutz Pogrell, Md Haris Iqbal)
- lightnvm NULL pointer deref fix (tangzhenhao)
- sr in_interrupt() removal (Sebastian Andrzej Siewior)
- FC endpoint security support for s390/dasd (Jan Höppner, Sebastian
Ott, Vineeth Vijayan). From the s390 arch guys, arch bits included
as it made it easier for them to funnel the feature through the
block driver tree.
- Follow up fixes (Colin Ian King)"
* tag 'for-5.11/drivers-2020-12-14' of git://git.kernel.dk/linux-block: (64 commits)
block: drop dead assignments in loop_init()
sr: Remove in_interrupt() usage in sr_init_command().
sr: Switch the sector size back to 2048 if sr_read_sector() changed it.
cdrom: Reset sector_size back it is not 2048.
drivers/lightnvm: fix a null-ptr-deref bug in pblk-core.c
null_blk: Move driver into its own directory
null_blk: Allow controlling max_hw_sectors limit
null_blk: discard zones on reset
null_blk: cleanup discard handling
null_blk: Improve implicit zone close
null_blk: improve zone locking
block: Align max_hw_sectors to logical blocksize
null_blk: Fail zone append to conventional zones
null_blk: Fix zone size initialization
bcache: fix race between setting bdev state to none and new write request direct to backing
block/rnbd: fix a null pointer dereference on dev->blk_symlink_name
block/rnbd-clt: Dynamically alloc buffer for pathname & blk_symlink_name
block/rnbd: call kobject_put in the failure path
Documentation/ABI/rnbd-srv: add document for force_close
block/rnbd-srv: close a mapped device from server side.
...
-----BEGIN PGP SIGNATURE-----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=zo4w
-----END PGP SIGNATURE-----
Merge tag 'for-5.11/block-2020-12-14' of git://git.kernel.dk/linux-block
Pull block updates from Jens Axboe:
"Another series of killing more code than what is being added, again
thanks to Christoph's relentless cleanups and tech debt tackling.
This contains:
- blk-iocost improvements (Baolin Wang)
- part0 iostat fix (Jeffle Xu)
- Disable iopoll for split bios (Jeffle Xu)
- block tracepoint cleanups (Christoph Hellwig)
- Merging of struct block_device and hd_struct (Christoph Hellwig)
- Rework/cleanup of how block device sizes are updated (Christoph
Hellwig)
- Simplification of gendisk lookup and removal of block device
aliasing (Christoph Hellwig)
- Block device ioctl cleanups (Christoph Hellwig)
- Removal of bdget()/blkdev_get() as exported API (Christoph Hellwig)
- Disk change rework, avoid ->revalidate_disk() (Christoph Hellwig)
- sbitmap improvements (Pavel Begunkov)
- Hybrid polling fix (Pavel Begunkov)
- bvec iteration improvements (Pavel Begunkov)
- Zone revalidation fixes (Damien Le Moal)
- blk-throttle limit fix (Yu Kuai)
- Various little fixes"
* tag 'for-5.11/block-2020-12-14' of git://git.kernel.dk/linux-block: (126 commits)
blk-mq: fix msec comment from micro to milli seconds
blk-mq: update arg in comment of blk_mq_map_queue
blk-mq: add helper allocating tagset->tags
Revert "block: Fix a lockdep complaint triggered by request queue flushing"
nvme-loop: use blk_mq_hctx_set_fq_lock_class to set loop's lock class
blk-mq: add new API of blk_mq_hctx_set_fq_lock_class
block: disable iopoll for split bio
block: Improve blk_revalidate_disk_zones() checks
sbitmap: simplify wrap check
sbitmap: replace CAS with atomic and
sbitmap: remove swap_lock
sbitmap: optimise sbitmap_deferred_clear()
blk-mq: skip hybrid polling if iopoll doesn't spin
blk-iocost: Factor out the base vrate change into a separate function
blk-iocost: Factor out the active iocgs' state check into a separate function
blk-iocost: Move the usage ratio calculation to the correct place
blk-iocost: Remove unnecessary advance declaration
blk-iocost: Fix some typos in comments
blktrace: fix up a kerneldoc comment
block: remove the request_queue to argument request based tracepoints
...
Set nvme-loop's lock class via blk_mq_hctx_set_fq_lock_class for avoiding
lockdep possible recursive locking, then we can remove the dynamically
allocated lock class for each flush queue, finally we can avoid horrible
SCSI probe delay.
This way may not address situation in which one nvme-loop is backed on
another nvme-loop. However, in reality, people seldom uses this way
for test. Even though someone played in this way, it is just one
recursive locking false positive, no real deadlock issue.
Tested-by: Kashyap Desai <kashyap.desai@broadcom.com>
Reported-by: Qian Cai <cai@redhat.com>
Reviewed-by: Christoph Hellwig <hch@lst.de>
Cc: Sumit Saxena <sumit.saxena@broadcom.com>
Cc: John Garry <john.garry@huawei.com>
Cc: Kashyap Desai <kashyap.desai@broadcom.com>
Cc: Bart Van Assche <bvanassche@acm.org>
Cc: Hannes Reinecke <hare@suse.de>
Signed-off-by: Ming Lei <ming.lei@redhat.com>
Reviewed-by: Hannes Reinecke <hare@suse.de>
Signed-off-by: Jens Axboe <axboe@kernel.dk>
The request_queue can trivially be derived from the bio.
Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Damien Le Moal <damien.lemoal@wdc.com>
Reviewed-by: Hannes Reinecke <hare@suse.de>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Acked-by: Tejun Heo <tj@kernel.org>
Signed-off-by: Jens Axboe <axboe@kernel.dk>
Use struct block_device to lookup partitions on a disk. This removes
all usage of struct hd_struct from the I/O path.
Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Jan Kara <jack@suse.cz>
Reviewed-by: Hannes Reinecke <hare@suse.de>
Acked-by: Coly Li <colyli@suse.de> [bcache]
Acked-by: Chao Yu <yuchao0@huawei.com> [f2fs]
Signed-off-by: Jens Axboe <axboe@kernel.dk>
Allow ZNS NVMe SSDs to present a read-only namespace when append is not
supported, instead of rejecting the namespace directly.
This allows (i) the namespace to be used in read-only mode, which is not
a problem as the append command only affects the write path, and (ii) to
use standard management tools such as nvme-cli to choose a different
format or firmware slot that is compatible with the Linux zoned block
device.
Signed-off-by: Javier González <javier.gonz@samsung.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Remane block device operations in preparation to add char device file
operations.
Signed-off-by: Javier González <javier.gonz@samsung.com>
Reviewed-by: Minwoo Im <minwoo.im.dev@gmail.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Rename controller base dev_t char device in preparation for adding a
namespace char device.
Signed-off-by: Javier González <javier.gonz@samsung.com>
Reviewed-by: Minwoo Im <minwoo.im.dev@gmail.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Cleanup unnecessary ret values that are not checked or used in
nvme_alloc_ns().
Signed-off-by: Javier González <javier.gonz@samsung.com>
Reviewed-by: Minwoo Im <minwoo.im.dev@gmail.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
During the scan_work, an Identify command is issued to figure out which
namespaces are active. If this command fails, the nvme driver falls back
to scanning namespaces sequentially. In this situation, we don't see
any warnings and don't even know whether list-ns command has been failed
or not easiliy.
Printa warning when the Identify command executin fail:
[ 1.108399] nvme nvme0: Identify NS List failed (status=0x400b)
[ 1.109583] nvme0n1: detected capacity change from 0 to 1048576
[ 1.112186] nvme nvme0: Identify Descriptors failed (nsid=2, status=0x4002)
[ 1.113929] nvme nvme0: Identify Descriptors failed (nsid=3, status=0x4002)
[ 1.116537] nvme nvme0: Identify Descriptors failed (nsid=4, status=0x4002)
...
Signed-off-by: Minwoo Im <minwoo.im.dev@gmail.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Add the namespace ID to the error message when the Identify command used
to retrieve the Namespace Identification Descriptor list fails.
This avoids rather useless and duplicative messages like the following:
[ 1.321031] nvme nvme0: Identify Descriptors failed (16386)
[ 1.321948] nvme nvme0: Identify Descriptors failed (16386)
[ 1.322872] nvme nvme0: Identify Descriptors failed (16386)
[ 1.323775] nvme nvme0: Identify Descriptors failed (16386)
[ 1.324687] nvme nvme0: Identify Descriptors failed (16386)
...
Also, print the nvme status code in hexadecimal rather than decimal
format rather for better readability.
Signed-off-by: Minwoo Im <minwoo.im.dev@gmail.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Commands get stuck while Host NVMe-oF controller is in reconnect state.
The controller enters into reconnect state when it loses connection with
the target. It tries to reconnect every 10 seconds (default) until
a successful reconnect or until the reconnect time-out is reached.
The default reconnect time out is 10 minutes.
Applications are expecting commands to complete with success or error
within a certain timeout (30 seconds by default). The NVMe host is
enforcing that timeout while it is connected, but during reconnect the
timeout is not enforced and commands may get stuck for a long period or
even forever.
To fix this long delay due to the default timeout, introduce new
"fast_io_fail_tmo" session parameter. The timeout is measured in seconds
from the controller reconnect and any command beyond that timeout is
rejected. The new parameter value may be passed during 'connect'.
The default value of -1 means no timeout (similar to current behavior).
Signed-off-by: Victor Gladkov <victor.gladkov@kioxia.com>
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Reviewed-by: Hannes Reinecke <hare@suse.de>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: Chao Leng <lengchao@huawei.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
There is a spelling mistake in the Kconfig help text. Fix it.
Signed-off-by: Colin Ian King <colin.king@canonical.com>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Generation counter is protected by nvmet_config_sem. Make sure the
callers that call functions that might change it, are calling it
properly.
Signed-off-by: Max Gurtovoy <mgurtovoy@nvidia.com>
Reviewed-by: Israel Rukshin <israelr@nvidia.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
remove unused cqs from nvmet_ctrl struct
this will reduce the allocated memory.
Signed-off-by: Amit <amit.engel@dell.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
currently the NVME_QUIRK_SHARED_TAGS quirk for Apple devices is handled
during the assignment of nr_io_queues in nvme_setup_io_queues().
This however means that for these devices nvme_max_io_queues() will
actually not return the supported maximum which is confusing and
unexpected and also means that in nvme_probe() we are allocating
for I/O queues that will never be used.
Fix this by moving the quirk handling into nvme_max_io_queues().
Signed-off-by: Niklas Schnelle <schnelle@linux.ibm.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
in nvme_setup_io_queues() the number of I/O queues is set to either 1 in
case of a quirky Apple device or to the min of nvme_max_io_queues() or
dev->nr_allocated_queues - 1.
This is unnecessarily complicated as dev->nr_allocated_queues is only
assigned once and is nvme_max_io_queues() + 1.
Signed-off-by: Niklas Schnelle <schnelle@linux.ibm.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
In nvmet_passthru_execute_cmd() which is a high frequency function
it uses bio_alloc() which leads to memory allocation from the fs pool
for each I/O.
For NVMeoF nvmet_req we already have inline_bvec allocated as a part of
request allocation that can be used with preallocated bio when we
already know the size of request before bio allocation with bio_alloc(),
which we already do.
Introduce a bio member for the nvmet_req passthru anon union. In the
fast path, check if we can get away with inline bvec and bio from
nvmet_req with bio_init() call before actually allocating from the
bio_alloc().
This will be useful to avoid any new memory allocation under high
memory pressure situation and get rid of any extra work of
allocation (bio_alloc()) vs initialization (bio_init()) when
transfer len is < NVMET_MAX_INLINE_DATA_LEN that user can configure at
compile time.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Reviewed-by: Logan Gunthorpe <logang@deltatee.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
The function blk_rq_append_bio() is a genereric API written for all
types driver (having bounce buffers) and different context (where
request is already having a bio i.e. rq->bio != NULL).
It does mainly three things: calculating the segments, bounce queue and
if req->bio == NULL call blk_rq_bio_prep() or handle low level merge()
case.
The NVMe PCIe and fabrics transports currently does not use queue
bounce mechanism. In order to find this for each request processing
in the passthru blk_rq_append_bio() does extra work in the fast path
for each request.
When I ran I/Os with different block sizes on the passthru controller
I found that we can reuse the req->sg_cnt instead of iterating over the
bvecs to find out nr_segs in blk_rq_append_bio(). This calculation in
blk_rq_append_bio() is a duplication of work given that we have the
value in req->sg_cnt. (correct me here if I'm wrong).
With NVMe passthru request based driver we allocate fresh request each
time, so every call to blk_rq_append_bio() rq->bio will be NULL i.e.
we don't really need the second condition in the blk_rq_append_bio()
and the resulting error condition in the caller of blk_rq_append_bio().
So for NVMeOF passthru driver recalculating the segments, bounce check
and ll_back_merge code is not needed such that we can get away with the
minimal version of the blk_rq_append_bio() which removes the error check
in the fast path along with extra variable in nvmet_passthru_map_sg().
This patch updates the nvmet_passthru_map_sg() such that it does only
appending the bio to the request in the context of the NVMeOF Passthru
driver. Following are perf numbers :-
With current implementation (blk_rq_append_bio()) :-
----------------------------------------------------
+ 5.80% 0.02% kworker/0:2-mm_ [nvmet] [k] nvmet_passthru_execute_cmd
+ 5.44% 0.01% kworker/0:2-mm_ [nvmet] [k] nvmet_passthru_execute_cmd
+ 4.88% 0.00% kworker/0:2-mm_ [nvmet] [k] nvmet_passthru_execute_cmd
+ 5.44% 0.01% kworker/0:2-mm_ [nvmet] [k] nvmet_passthru_execute_cmd
+ 4.86% 0.01% kworker/0:2-mm_ [nvmet] [k] nvmet_passthru_execute_cmd
+ 5.17% 0.00% kworker/0:2-eve [nvmet] [k] nvmet_passthru_execute_cmd
With this patch using blk_rq_bio_prep() :-
----------------------------------------------------
+ 3.14% 0.02% kworker/0:2-eve [nvmet] [k] nvmet_passthru_execute_cmd
+ 3.26% 0.01% kworker/0:2-eve [nvmet] [k] nvmet_passthru_execute_cmd
+ 5.37% 0.01% kworker/0:2-mm_ [nvmet] [k] nvmet_passthru_execute_cmd
+ 5.18% 0.02% kworker/0:2-eve [nvmet] [k] nvmet_passthru_execute_cmd
+ 4.84% 0.02% kworker/0:2-mm_ [nvmet] [k] nvmet_passthru_execute_cmd
+ 4.87% 0.01% kworker/0:2-mm_ [nvmet] [k] nvmet_passthru_execute_cmd
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Reviewed-by: Logan Gunthorpe <logang@deltatee.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
For passthru commands setting op_flags has no meaning. Remove the code
that sets the op flags in nvmet_passthru_map_sg().
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Reviewed-by: Logan Gunthorpe <logang@deltatee.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Right now nvme_alloc_request() allocates a request from block layer
based on the value of the qid. When qid set to NVME_QID_ANY it used
blk_mq_alloc_request() else blk_mq_alloc_request_hctx().
The function nvme_alloc_request() is called from different context, The
only place where it uses non NVME_QID_ANY value is for fabrics connect
commands :-
nvme_submit_sync_cmd() NVME_QID_ANY
nvme_features() NVME_QID_ANY
nvme_sec_submit() NVME_QID_ANY
nvmf_reg_read32() NVME_QID_ANY
nvmf_reg_read64() NVME_QID_ANY
nvmf_reg_write32() NVME_QID_ANY
nvmf_connect_admin_queue() NVME_QID_ANY
nvme_submit_user_cmd() NVME_QID_ANY
nvme_alloc_request()
nvme_keep_alive() NVME_QID_ANY
nvme_alloc_request()
nvme_timeout() NVME_QID_ANY
nvme_alloc_request()
nvme_delete_queue() NVME_QID_ANY
nvme_alloc_request()
nvmet_passthru_execute_cmd() NVME_QID_ANY
nvme_alloc_request()
nvmf_connect_io_queue() QID
__nvme_submit_sync_cmd()
nvme_alloc_request()
With passthru nvme_alloc_request() now falls into the I/O fast path such
that blk_mq_alloc_request_hctx() is never gets called and that adds
additional branch check in fast path.
Split the nvme_alloc_request() into nvme_alloc_request() and
nvme_alloc_request_qid().
Replace each call of the nvme_alloc_request() with NVME_QID_ANY param
with a call to newly added nvme_alloc_request() without NVME_QID_ANY.
Replace a call to nvme_alloc_request() with QID param with a call to
newly added nvme_alloc_request() and nvme_alloc_request_qid()
based on the qid value set in the __nvme_submit_sync_cmd().
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Reviewed-by: Logan Gunthorpe <logang@deltatee.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
NVMeOF controller in the passsthru mode is capable of handling wide set
of I/O commands including vender specific passhtru io comands.
The vendor specific I/O commands are used to read the large drive
logs and can take longer than default NVMe commands, i.e. for
passthru requests the timeout value may differ from the passthru
controller's default timeout values (nvme-core:io_timeout).
Add a configfs attribute so that user can set the io timeout values.
In case if this configfs value is not set nvme_alloc_request() will set
the NVME_IO_TIMEOUT value when request queuedata is NULL.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
NVMeOF controller in the passsthru mode is capable of handling wide set
of admin commands including vender specific passhtru admin comands.
The vendor specific admin commands are used to read the large drive
logs and can take longer than default NVMe commands, i.e. for
passthru requests the timeout value may differ from the passthru
controller's default timeout values (nvme-core:admin_timeout).
Add a configfs attribute so that user can set the admin timeout values.
In case if this configfs value is not set nvme_alloc_request() will set
the ADMIN_TIMEOUT value when request queuedata is NULL.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
This is purely a clenaup patch, add prefix NVME to the ADMIN_TIMEOUT to
make consistent with NVME_IO_TIMEOUT.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
The function nvme_alloc_request() is called from different context
(I/O and Admin queue) where callers do not consider the I/O timeout when
called from I/O queue context.
Update nvme_alloc_request() to set the default I/O and Admin timeout
value based on whether the queuedata is set or not.
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Use the request's '->mq_hctx->queue_num' directly to simplify the
nvme_req_qid() function.
Signed-off-by: Baolin Wang <baolin.wang@linux.alibaba.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Add sysfs attribute to specify parameters for dropping a command. The
attribute takes a string of:
<opcode>:<starting a what instance>:<number of times>
Opcode is formatted as lower 8 bits are opcode. If a fabrics opcode, a
bit above bits 7:0 will be set.
Once set, each sqe is looked at. If the opcode matches the running
instance count is updated. If the instance count is in the range of where
to drop (based on starting and # of times), then drop the command by not
passing it to the target layer.
Signed-off-by: James Smart <james.smart@broadcom.com>
-----BEGIN PGP SIGNATURE-----
iQFSBAABCAA8FiEEq68RxlopcLEwq+PEeb4+QwBBGIYFAl+69egeHHRvcnZhbGRz
QGxpbnV4LWZvdW5kYXRpb24ub3JnAAoJEHm+PkMAQRiGTSYH/ifRBlaxy5UiHFc0
2zdR7pkjWrYfDTTT3sazIAhdlzzcfnkUqgFxOP45F4ZIqeTzunH3sUY+5UlT9IX7
liUgnLxQ/1R9Gx8kPGQfu+tLCey78xVFydGsqJoW9sPRw2R+apMdGGa/lOrk+OXz
DXIN+dDnGFqwCCNJpK+rxQQhFf++IPpSI8z6Y23moOFhsDZrEziHuVFy2FGyRM6z
prZ/us/tcobE8ptCk1RmOxLoJ1DR6UxpA2vLimTE+JD8siOsSWPbjE0KudnWCnd5
BLqIjrsPJbSxyuzzK3v9dnO5wMv7tMDuMIuYM/MQTXDttNwtsqt/aP6gdnUCym7N
5eHEj5g=
=MuO1
-----END PGP SIGNATURE-----
Merge tag 'v5.10-rc5' into rdma.git for-next
For dependencies in following patches
Signed-off-by: Jason Gunthorpe <jgg@nvidia.com>
Use the ib_dma_* helpers to skip the DMA translation instead. This
removes the last user if dma_virt_ops and keeps the weird layering
violation inside the RDMA core instead of burderning the DMA mapping
subsystems with it. This also means the software RDMA drivers now don't
have to mess with DMA parameters that are not relevant to them at all, and
that in the future we can use PCI P2P transfers even for software RDMA, as
there is no first fake layer of DMA mapping that the P2P DMA support.
Link: https://lore.kernel.org/r/20201106181941.1878556-8-hch@lst.de
Signed-off-by: Christoph Hellwig <hch@lst.de>
Tested-by: Mike Marciniszyn <mike.marciniszyn@cornelisnetworks.com>
Signed-off-by: Jason Gunthorpe <jgg@nvidia.com>
Use the block layer helper to update both the disk and block device
sizes. Contrary to the name no notification is sent in this case,
as a size 0 is special cased.
Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Hannes Reinecke <hare@suse.de>
Signed-off-by: Jens Axboe <axboe@kernel.dk>
The update_bdev argument is always set to true, so remove it. Also
rename the function to the slighly less verbose set_capacity_and_notify,
as propagating the disk size to the block device isn't really
revalidation.
Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Hannes Reinecke <hare@suse.de>
Reviewed-by: Petr Vorel <pvorel@suse.cz>
Signed-off-by: Jens Axboe <axboe@kernel.dk>
There is no good reason to call revalidate_disk_size separately.
Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Hannes Reinecke <hare@suse.de>
Signed-off-by: Jens Axboe <axboe@kernel.dk>
xa_destroy() frees only internal data. The caller is responsible for
freeing the exteranl objects referenced by an xarray.
Fixes: 1cf7a12e09 ("nvme: use an xarray to lookup the Commands Supported and Effects log")
Signed-off-by: Keith Busch <kbusch@kernel.org>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Remove the struct used for tracking known command effects logs in a
list. This is now saved in an xarray that doesn't use these elements.
Instead, store the log directly instead of the wrapper struct.
Signed-off-by: Keith Busch <kbusch@kernel.org>
Signed-off-by: Christoph Hellwig <hch@lst.de>
If Doorbell Buffer Config command fails even 'dev->dbbuf_dbs != NULL'
which means OACS indicates that NVME_CTRL_OACS_DBBUF_SUPP is set,
nvme_dbbuf_update_and_check_event() will check event even it's not been
successfully set.
This patch fixes mismatch among dbbuf for sq/cqs in case that dbbuf
command fails.
Signed-off-by: Minwoo Im <minwoo.im.dev@gmail.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>