Commit Graph

12 Commits

Author SHA1 Message Date
Aleksa Savic
aed80bb91d hwmon: (aquacomputer_d5next) Add support for Aquacomputer High Flow Next
Extend aquacomputer_d5next driver to expose various hardware
sensors of the Aquacomputer High Flow Next flow sensor, which
communicates through a proprietary USB HID protocol.

The High Flow Next exposes +5V voltages, water quality, conductivity
and flow readings. A temperature sensor can be connected to it, in
which case it provides its reading and an estimation of the
dissipated/absorbed power in the liquid cooling loop.

Additionally, serial number and firmware version are exposed through
debugfs.

Registry offsets were discovered and tested by users on Github [1] [2].

[1] https://github.com/aleksamagicka/aquacomputer_d5next-hwmon/issues/8
[2] https://github.com/aleksamagicka/aquacomputer_d5next-hwmon/pull/34

Signed-off-by: Aleksa Savic <savicaleksa83@gmail.com>
Link: https://lore.kernel.org/r/20220907100739.806571-1-savicaleksa83@gmail.com
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2022-09-19 06:17:06 -07:00
Aleksa Savic
e2769f5e7f hwmon: (aquacomputer_d5next) Add support for reading virtual temp sensors
Add support for reading virtual temperature sensors for the D5 Next, Octo,
Quadro and Farbwerk 360.

Virtual temperature sensors are written to the device by the user, pulling
from an arbitrary value source. Writing to them is not yet reverse
engineered, so the only way to set them for now is to use the official
software.

Signed-off-by: Aleksa Savic <savicaleksa83@gmail.com>
Link: https://lore.kernel.org/r/20220817121441.112198-1-savicaleksa83@gmail.com
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2022-09-19 06:17:05 -07:00
Aleksa Savic
b7f3e9650f hwmon: (aquacomputer_d5next) Fix Quadro fan speed offsets
The offsets for setting speeds of fans connected to Quadro are off by one.
Set them to their correct values.

The offsets as shown point to registers for setting the fan control mode,
which will be explored in future patches, but slipped in here. When
setting fan speeds, the resulting values were overlapping, which made the
fans still run in my initial testing.

Fixes: cdbe34da01 ("hwmon: (aquacomputer_d5next) Add support for Aquacomputer Quadro fan controller")
Signed-off-by: Aleksa Savic <savicaleksa83@gmail.com>
Link: https://lore.kernel.org/r/20220914114327.6941-1-savicaleksa83@gmail.com
Cc: stable@vger.kenrel.org
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2022-09-19 06:14:09 -07:00
Aleksa Savic
cdbe34da01 hwmon: (aquacomputer_d5next) Add support for Aquacomputer Quadro fan controller
Extend aquacomputer_d5next driver to expose hardware temperature sensors
and fans of the Aquacomputer Quadro fan controller, which communicates
through a proprietary USB HID protocol. Implemented by Jack Doan [1].

Four temperature sensors and PWM controllable fans are available. The
liquid flow sensor is also exposed, implemented by Leonard Anderweit [2].

Additionally, serial number, firmware version and power-on count are
exposed through debugfs.

This driver has been tested on x86_64.

[1] https://github.com/aleksamagicka/aquacomputer_d5next-hwmon/pull/5
[2] https://github.com/aleksamagicka/aquacomputer_d5next-hwmon/pull/9

Originally-from: Jack Doan <me@jackdoan.com>
Originally-from: Leonard Anderweit <leonard.anderweit@gmail.com>
Signed-off-by: Aleksa Savic <savicaleksa83@gmail.com>
Link: https://lore.kernel.org/r/20220727100606.9328-1-savicaleksa83@gmail.com
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2022-07-27 06:00:24 -07:00
Aleksa Savic
f4caa26216 hwmon: (aquacomputer_d5next) Add support for reading the +12V voltage sensor on D5 Next
Add support for reading the +12V voltage that the D5 Next pump receives.

Signed-off-by: Aleksa Savic <savicaleksa83@gmail.com>
Link: https://lore.kernel.org/r/20220726120203.33773-1-savicaleksa83@gmail.com
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2022-07-26 06:30:29 -07:00
Aleksa Savic
09e893092e hwmon: (aquacomputer_d5next) Add D5 Next fan control support
Define pump and fan speed register offsets in
D5 Next control report, as well as its size, to expose PWM fan control.

Originally-from: Jack Doan <me@jackdoan.com>
Signed-off-by: Aleksa Savic <savicaleksa83@gmail.com>
Link: https://lore.kernel.org/r/20220717171412.11142-1-savicaleksa83@gmail.com
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2022-07-21 07:15:55 -07:00
Aleksa Savic
654c97351b hwmon: (aquacomputer_d5next) Move device-specific data into struct aqc_data
As preparation for adding support for more devices in upcoming patches,
move device-specific data, such as number of fans, temperature sensors,
register offsets etc. to struct aqc_data. This is made possible by
the fact that the supported Aquacomputer devices share the same layouts
of sensor substructures. This allows aqc_raw_event() and others to stay
general and not be cluttered with similar loops for each device.

Signed-off-by: Jack Doan <me@jackdoan.com>
Signed-off-by: Aleksa Savic <savicaleksa83@gmail.com>
Link: https://lore.kernel.org/r/20220707115050.90021-1-savicaleksa83@gmail.com
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2022-07-13 08:39:42 -07:00
Christophe JAILLET
8877ecb0fc hwmon: (aquacomputer_d5next) Fix an error handling path in aqc_probe()
If no memory can be allocated, some resources still need to be released as
already done in the other error handling paths.

Fixes: 752b927951 ("hwmon: (aquacomputer_d5next) Add support for Aquacomputer Octo")
Signed-off-by: Christophe JAILLET <christophe.jaillet@wanadoo.fr>
Link: https://lore.kernel.org/r/be6b955d50de140fcc96bd116150b435021bf567.1653225250.git.christophe.jaillet@wanadoo.fr
Reviewed-by: Aleksa Savic <savicaleksa83@gmail.com>
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2022-05-22 12:25:55 -07:00
Jack Doan
229b159c50 hwmon: (aquacomputer_d5next) Add support for Aquacomputer Farbwerk
Extend aquacomputer_d5next driver to expose hardware
temperature sensors of the Aquacomputer Farbwerk RGB controller, which
communicates through a proprietary USB HID protocol.

Four temperature sensors are available. Additionally, serial number and
firmware version are exposed through debugfs.

Also, add Jack Doan to MAINTAINERS for this driver.

Signed-off-by: Jack Doan <me@jackdoan.com>
Signed-off-by: Aleksa Savic <savicaleksa83@gmail.com>
Link: https://lore.kernel.org/r/YmTcrq8Gzel0zYYD@jackdesk
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2022-05-20 10:57:05 -07:00
Aleksa Savic
752b927951 hwmon: (aquacomputer_d5next) Add support for Aquacomputer Octo
Extend aquacomputer_d5next driver to expose hardware temperature sensors
and fans of the Aquacomputer Octo fan controller, which communicates
through a proprietary USB HID protocol.

Four temperature sensors and eight PWM controllable fans are available.
Additionally, serial number, firmware version and power-on count are
exposed through debugfs.

This driver has been tested on x86_64.

Signed-off-by: Aleksa Savic <savicaleksa83@gmail.com>
Link: https://lore.kernel.org/r/20220404134212.9690-1-savicaleksa83@gmail.com
[groeck: Add missing "select CRC16"]
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2022-05-17 05:52:59 -07:00
Aleksa Savic
2fd3eec19c hwmon: (aquacomputer_d5next) Add support for Aquacomputer Farbwerk 360
Extend aquacomputer_d5next driver to expose hardware temperature sensors
of the Aquacomputer Farbwerk 360 RGB controller, which communicates through
a proprietary USB HID protocol.

Four temperature sensors are available. Additionally, serial number and
firmware version are exposed through debugfs.

This driver has been tested on x86_64.

Signed-off-by: Aleksa Savic <savicaleksa83@gmail.com>
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2022-02-27 17:03:23 -08:00
Aleksa Savic
0e35f63f7f hwmon: add driver for Aquacomputer D5 Next
This driver exposes hardware sensors of the Aquacomputer D5 Next
watercooling pump, which communicates through a proprietary USB HID
protocol.

Available sensors are pump and fan speed, power, voltage and current, as
well as coolant temperature. Also available through debugfs are the serial
number, firmware version and power-on count.

Attaching a fan is optional and allows it to be controlled using
temperature curves directly from the pump. If it's not connected,
the fan-related sensors will report zeroes.

The pump can be configured either through software or via its physical
interface. Configuring the pump through this driver is not implemented,
as it seems to require sending it a complete configuration. That
includes addressable RGB LEDs, for which there is no standard sysfs
interface. Thus, that task is better suited for userspace tools.

This driver has been tested on x86_64, both in-kernel and as a module.

Signed-off-by: Aleksa Savic <savicaleksa83@gmail.com>
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2021-08-28 08:53:30 -07:00