net: phy: lan87xx: fix access to wrong register of LAN87xx
The function lan87xx_config_aneg_ext was introduced to configure
LAN95xxA but as well writes to undocumented register of LAN87xx.
This fix prevents that access.
The function lan87xx_config_aneg_ext gets more suitable for the new
behavior name.
Reported-by: Måns Rullgård <mans@mansr.com>
Fixes: 05b35e7eb9 ("smsc95xx: add phylib support")
Signed-off-by: Andre Edich <andre.edich@microchip.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
			
			
This commit is contained in:
		
							parent
							
								
									9c0ee085c4
								
							
						
					
					
						commit
						fdb5cc6ab3
					
				| @ -185,10 +185,13 @@ static int lan87xx_config_aneg(struct phy_device *phydev) | ||||
| 	return genphy_config_aneg(phydev); | ||||
| } | ||||
| 
 | ||||
| static int lan87xx_config_aneg_ext(struct phy_device *phydev) | ||||
| static int lan95xx_config_aneg_ext(struct phy_device *phydev) | ||||
| { | ||||
| 	int rc; | ||||
| 
 | ||||
| 	if (phydev->phy_id != 0x0007c0f0) /* not (LAN9500A or LAN9505A) */ | ||||
| 		return lan87xx_config_aneg(phydev); | ||||
| 
 | ||||
| 	/* Extend Manual AutoMDIX timer */ | ||||
| 	rc = phy_read(phydev, PHY_EDPD_CONFIG); | ||||
| 	if (rc < 0) | ||||
| @ -441,7 +444,7 @@ static struct phy_driver smsc_phy_driver[] = { | ||||
| 	.read_status	= lan87xx_read_status, | ||||
| 	.config_init	= smsc_phy_config_init, | ||||
| 	.soft_reset	= smsc_phy_reset, | ||||
| 	.config_aneg	= lan87xx_config_aneg_ext, | ||||
| 	.config_aneg	= lan95xx_config_aneg_ext, | ||||
| 
 | ||||
| 	/* IRQ related */ | ||||
| 	.config_intr	= smsc_phy_config_intr, | ||||
|  | ||||
		Loading…
	
		Reference in New Issue
	
	Block a user