HID: input: do not report stylus battery state as "full"
The power supply states of discharging, charging, full, etc, represent state of charging, not the capacity level of the battery (for which we have a separate property). Current HID usage tables to not allow for expressing charging state of the batteries found in generic styli, so we should simply assume that the battery is discharging even if current capacity is at 100% when battery strength reporting is done via HID interface. In fact, we were doing just that before commit581c448476
. This change helps UIs to not mis-represent fully charged batteries in styli as being charging/topping-off. Fixes:581c448476
("HID: input: map digitizer battery usage") Reported-by: Kenneth Albanowski <kenalba@google.com> Signed-off-by: Dmitry Torokhov <dmitry.torokhov@gmail.com> Signed-off-by: Jiri Kosina <jkosina@suse.cz>
This commit is contained in:
parent
df04fbe868
commit
f4abaa9eeb
@ -419,8 +419,6 @@ static int hidinput_get_battery_property(struct power_supply *psy,
|
||||
|
||||
if (dev->battery_status == HID_BATTERY_UNKNOWN)
|
||||
val->intval = POWER_SUPPLY_STATUS_UNKNOWN;
|
||||
else if (dev->battery_capacity == 100)
|
||||
val->intval = POWER_SUPPLY_STATUS_FULL;
|
||||
else
|
||||
val->intval = POWER_SUPPLY_STATUS_DISCHARGING;
|
||||