forked from Minki/linux
ACPI / thermal: Fix wrong variable usage in debug statement
A debug statement in acpi_thermal_trips_update() uses a wrong trip point (tz->trips.critical instead of tz->trips.hot) to get the temperature value from. Fix that. Signed-off-by: Zhihui Zhang <zzhsuny@gmail.com> [rjw: Subject and changelog] Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
This commit is contained in:
parent
70f6c08757
commit
ee17fdf24b
@ -344,7 +344,7 @@ static int acpi_thermal_trips_update(struct acpi_thermal *tz, int flag)
|
||||
tz->trips.hot.flags.valid = 1;
|
||||
ACPI_DEBUG_PRINT((ACPI_DB_INFO,
|
||||
"Found hot threshold [%lu]\n",
|
||||
tz->trips.critical.temperature));
|
||||
tz->trips.hot.temperature));
|
||||
}
|
||||
}
|
||||
|
||||
|
Loading…
Reference in New Issue
Block a user