dt-bindings: clock: add description of LPC32xx clock controller
NXP LPC32xx SoC has a clocking and power control unit (CPC) as a part of system control block (SCB). CPC is supplied by two external oscillators and it manages core and most of peripheral clocks, the change adds description of DT bindings for clock controller found on LPC32xx SoC series. Signed-off-by: Vladimir Zapolskiy <vz@mleia.com> Acked-by: Rob Herring <robh@kernel.org> Signed-off-by: Michael Turquette <mturquette@baylibre.com>
This commit is contained in:
parent
8005c49d9a
commit
92e16f0fb2
30
Documentation/devicetree/bindings/clock/nxp,lpc3220-clk.txt
Normal file
30
Documentation/devicetree/bindings/clock/nxp,lpc3220-clk.txt
Normal file
@ -0,0 +1,30 @@
|
||||
NXP LPC32xx Clock Controller
|
||||
|
||||
Required properties:
|
||||
- compatible: should be "nxp,lpc3220-clk"
|
||||
- reg: should contain clock controller registers location and length
|
||||
- #clock-cells: must be 1, the cell holds id of a clock provided by the
|
||||
clock controller
|
||||
- clocks: phandles of external oscillators, the list must contain one
|
||||
32768 Hz oscillator and may have one optional high frequency oscillator
|
||||
- clock-names: list of external oscillator clock names, must contain
|
||||
"xtal_32k" and may have optional "xtal"
|
||||
|
||||
Examples:
|
||||
|
||||
/* System Control Block */
|
||||
scb {
|
||||
compatible = "simple-bus";
|
||||
ranges = <0x0 0x040004000 0x00001000>;
|
||||
#address-cells = <1>;
|
||||
#size-cells = <1>;
|
||||
|
||||
clk: clock-controller@0 {
|
||||
compatible = "nxp,lpc3220-clk";
|
||||
reg = <0x00 0x114>;
|
||||
#clock-cells = <1>;
|
||||
|
||||
clocks = <&xtal_32k>, <&xtal>;
|
||||
clock-names = "xtal_32k", "xtal";
|
||||
};
|
||||
};
|