ab8500-btemp: Filter btemp readings
Battery tempreature readings sometimes fail and results in a value far from recent values. This patch adds a software filter that disposes such readings, by allowing direct updates on temperature only if two samples result in the same temperature. Else only allow 1 degree change from previous reported value in the direction of the new measurement. Signed-off-by: Hakan Berg <hakan.berg@stericsson.com> Signed-off-by: Lee Jones <lee.jones@linaro.org> Reviewed-by: Marcus COOPER <marcus.xm.cooper@stericsson.com> Reviewed-by: Martin SJOBLOM <martin.w.sjoblom@stericsson.com> Reviewed-by: Rabin VINCENT <rabin.vincent@stericsson.com>
This commit is contained in:
parent
d4f510f6c3
commit
908fe8d6a5
@ -76,8 +76,8 @@ struct ab8500_btemp_ranges {
|
||||
* @dev: Pointer to the structure device
|
||||
* @node: List of AB8500 BTEMPs, hence prepared for reentrance
|
||||
* @curr_source: What current source we use, in uA
|
||||
* @bat_temp: Battery temperature in degree Celcius
|
||||
* @prev_bat_temp Last dispatched battery temperature
|
||||
* @bat_temp: Dispatched battery temperature in degree Celcius
|
||||
* @prev_bat_temp Last measured battery temperature in degree Celcius
|
||||
* @parent: Pointer to the struct ab8500
|
||||
* @gpadc: Pointer to the struct gpadc
|
||||
* @fg: Pointer to the struct fg
|
||||
@ -604,6 +604,7 @@ static int ab8500_btemp_id(struct ab8500_btemp *di)
|
||||
static void ab8500_btemp_periodic_work(struct work_struct *work)
|
||||
{
|
||||
int interval;
|
||||
int bat_temp;
|
||||
struct ab8500_btemp *di = container_of(work,
|
||||
struct ab8500_btemp, btemp_periodic_work.work);
|
||||
|
||||
@ -614,12 +615,26 @@ static void ab8500_btemp_periodic_work(struct work_struct *work)
|
||||
dev_warn(di->dev, "failed to identify the battery\n");
|
||||
}
|
||||
|
||||
di->bat_temp = ab8500_btemp_measure_temp(di);
|
||||
|
||||
if (di->bat_temp != di->prev_bat_temp) {
|
||||
di->prev_bat_temp = di->bat_temp;
|
||||
bat_temp = ab8500_btemp_measure_temp(di);
|
||||
/*
|
||||
* Filter battery temperature.
|
||||
* Allow direct updates on temperature only if two samples result in
|
||||
* same temperature. Else only allow 1 degree change from previous
|
||||
* reported value in the direction of the new measurement.
|
||||
*/
|
||||
if (bat_temp == di->prev_bat_temp || !di->initialized) {
|
||||
if (di->bat_temp != di->prev_bat_temp || !di->initialized) {
|
||||
di->bat_temp = bat_temp;
|
||||
power_supply_changed(&di->btemp_psy);
|
||||
}
|
||||
} else if (bat_temp < di->prev_bat_temp) {
|
||||
di->bat_temp--;
|
||||
power_supply_changed(&di->btemp_psy);
|
||||
} else if (bat_temp > di->prev_bat_temp) {
|
||||
di->bat_temp++;
|
||||
power_supply_changed(&di->btemp_psy);
|
||||
}
|
||||
di->prev_bat_temp = bat_temp;
|
||||
|
||||
if (di->events.ac_conn || di->events.usb_conn)
|
||||
interval = di->bm->temp_interval_chg;
|
||||
|