ab8500-fg: Allow capacity to raise from 1% when charging
When battery capacity was going below 1% fg is not supposed to report 0% unless we've got the LOW_BAT IRQ, no matter what the FG-algorithm says. This made fg get stuck at 1% if charger is connected when capacity is 1%. Signed-off-by: Hakan BERG <hakan.berg@stericsson.com> Signed-off-by: Lee Jones <lee.jones@linaro.org> Reviewed-by: Marcus COOPER <marcus.xm.cooper@stericsson.com> Reviewed-by: Srinidhi KASAGAR <srinidhi.kasagar@stericsson.com>
This commit is contained in:
@@ -1354,9 +1354,6 @@ static void ab8500_fg_check_capacity_limits(struct ab8500_fg *di, bool init)
|
|||||||
* algorithm says.
|
* algorithm says.
|
||||||
*/
|
*/
|
||||||
di->bat_cap.prev_percent = 1;
|
di->bat_cap.prev_percent = 1;
|
||||||
di->bat_cap.permille = 1;
|
|
||||||
di->bat_cap.prev_mah = 1;
|
|
||||||
di->bat_cap.mah = 1;
|
|
||||||
percent = 1;
|
percent = 1;
|
||||||
|
|
||||||
changed = true;
|
changed = true;
|
||||||
@@ -1768,9 +1765,10 @@ static void ab8500_fg_algorithm(struct ab8500_fg *di)
|
|||||||
ab8500_fg_algorithm_discharging(di);
|
ab8500_fg_algorithm_discharging(di);
|
||||||
}
|
}
|
||||||
|
|
||||||
dev_dbg(di->dev, "[FG_DATA] %d %d %d %d %d %d %d %d %d "
|
dev_dbg(di->dev, "[FG_DATA] %d %d %d %d %d %d %d %d %d %d "
|
||||||
"%d %d %d %d %d %d %d\n",
|
"%d %d %d %d %d %d %d\n",
|
||||||
di->bat_cap.max_mah_design,
|
di->bat_cap.max_mah_design,
|
||||||
|
di->bat_cap.max_mah,
|
||||||
di->bat_cap.mah,
|
di->bat_cap.mah,
|
||||||
di->bat_cap.permille,
|
di->bat_cap.permille,
|
||||||
di->bat_cap.level,
|
di->bat_cap.level,
|
||||||
|
|||||||
Reference in New Issue
Block a user