drm/amd/display: Print type if we get wrong ObjectID from bios
We've seen a bunch of issues where we can't get the connector from vbios for what we think should be a valid connector id. Print some more info when this happens. Signed-off-by: Harry Wentland <harry.wentland@amd.com> Reviewed-by: Tony Cheng <Tony.Cheng@amd.com> Acked-by: Harry Wentland <harry.wentland@amd.com> Signed-off-by: Alex Deucher <alexander.deucher@amd.com>
This commit is contained in:
parent
0cadc8651d
commit
63b371ec54
@ -190,6 +190,7 @@ static struct graphics_object_id bios_parser_get_connector_id(
|
||||
struct bios_parser *bp = BP_FROM_DCB(dcb);
|
||||
struct graphics_object_id object_id = dal_graphics_object_id_init(
|
||||
0, ENUM_ID_UNKNOWN, OBJECT_TYPE_UNKNOWN);
|
||||
uint16_t id;
|
||||
|
||||
uint32_t connector_table_offset = bp->object_info_tbl_offset
|
||||
+ le16_to_cpu(bp->object_info_tbl.v1_1->usConnectorObjectTableOffset);
|
||||
@ -197,12 +198,19 @@ static struct graphics_object_id bios_parser_get_connector_id(
|
||||
ATOM_OBJECT_TABLE *tbl =
|
||||
GET_IMAGE(ATOM_OBJECT_TABLE, connector_table_offset);
|
||||
|
||||
if (tbl && tbl->ucNumberOfObjects > i) {
|
||||
const uint16_t id = le16_to_cpu(tbl->asObjects[i].usObjectID);
|
||||
|
||||
object_id = object_id_from_bios_object_id(id);
|
||||
if (!tbl) {
|
||||
dm_error("Can't get connector table from atom bios.\n");
|
||||
return object_id;
|
||||
}
|
||||
|
||||
if (tbl->ucNumberOfObjects <= i) {
|
||||
dm_error("Can't find connector id %d in connector table of size %d.\n",
|
||||
i, tbl->ucNumberOfObjects);
|
||||
return object_id;
|
||||
}
|
||||
|
||||
id = le16_to_cpu(tbl->asObjects[i].usObjectID);
|
||||
object_id = object_id_from_bios_object_id(id);
|
||||
return object_id;
|
||||
}
|
||||
|
||||
|
@ -938,8 +938,9 @@ static bool construct(
|
||||
link->link_id = bios->funcs->get_connector_id(bios, init_params->connector_index);
|
||||
|
||||
if (link->link_id.type != OBJECT_TYPE_CONNECTOR) {
|
||||
dm_error("%s: Invalid Connector ObjectID from Adapter Service for connector index:%d!\n",
|
||||
__func__, init_params->connector_index);
|
||||
dm_error("%s: Invalid Connector ObjectID from Adapter Service for connector index:%d! type %d expected %d\n",
|
||||
__func__, init_params->connector_index,
|
||||
link->link_id.type, OBJECT_TYPE_CONNECTOR);
|
||||
goto create_fail;
|
||||
}
|
||||
|
||||
|