arm64: dts: broadcom: Fix SP805 clock-names

The SP805 binding sets the name for the actual watchdog clock to
"wdog_clk" (with an underscore).

Change the name in the DTs for Broadcom platforms to match that. The
Linux and U-Boot driver use the *first* clock for this purpose anyway,
so it does not break anything.

Signed-off-by: Andre Przywara <andre.przywara@arm.com>
Reviewed-by: Ray Jui <ray.jui@broadcom.com>
Acked-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: Florian Fainelli <f.fainelli@gmail.com>
This commit is contained in:
Andre Przywara
2020-08-28 14:05:55 +01:00
committed by Florian Fainelli
parent ed23822eb2
commit 6534dfbbfa
2 changed files with 2 additions and 2 deletions

View File

@@ -576,7 +576,7 @@
reg = <0x66090000 0x1000>;
interrupts = <GIC_SPI 406 IRQ_TYPE_LEVEL_HIGH>;
clocks = <&iprocslow>, <&iprocslow>;
clock-names = "wdogclk", "apb_pclk";
clock-names = "wdog_clk", "apb_pclk";
};
gpio_g: gpio@660a0000 {

View File

@@ -438,7 +438,7 @@
reg = <0x000c0000 0x1000>;
interrupts = <GIC_SPI 189 IRQ_TYPE_LEVEL_HIGH>;
clocks = <&hsls_25m_div2_clk>, <&hsls_div4_clk>;
clock-names = "wdogclk", "apb_pclk";
clock-names = "wdog_clk", "apb_pclk";
timeout-sec = <60>;
};