The default setting for USB High Speed Squelch Threshold results in a threshold close to or lower than 100mV. This leads to Receiver Compliance test failure for a 100mV threshold. Shift the threshold from ~100mV towards ~130mV by setting SQRXTUNE to 0x0 to pass USB High Speed Receiver Sensitivity Compliance test. Signed-off-by: Sriram Dash <sriram.dash@nxp.com> Signed-off-by: Rajesh Bhagat <rajesh.bhagat@nxp.com> Signed-off-by: Suresh Gupta <suresh.gupta@nxp.com> Signed-off-by: Ran Wang <ran.wang_1@nxp.com> [YS: Reordered Kconfig options] Reviewed-by: York Sun <york.sun@nxp.com> |
||
---|---|---|
.. | ||
arm11 | ||
arm720t | ||
arm920t | ||
arm926ejs | ||
arm946es | ||
arm1136 | ||
arm1176 | ||
armv7 | ||
armv7m | ||
armv8 | ||
pxa | ||
sa1100 | ||
Makefile | ||
u-boot-spl.lds | ||
u-boot.lds |