From ceddd3e9a53953e65166ec1b04be37029bcd8dd6 Mon Sep 17 00:00:00 2001
From: Eugeniu Rosca <roscaeugeniu@gmail.com>
Date: Sat, 19 May 2018 14:13:51 +0200
Subject: [PATCH] board: eets: pdu001: Fix wrong default value in Kconfig

After importing linux v4.16-rc1 commit 2c37e08464a8 ("kconfig: Warn if
choice default is not in choice"), Kconfig complains:

scripts/kconfig/conf  --syncconfig Kconfig
board/eets/pdu001/Kconfig:22:warning:        \
  choice default symbol 'PDU001_RUN_LED_RED' \
  is not contained in the choice

This looks to be caused by a typo. Fix it.

Fixes: 85ab0452fefc ("arm: add support for PDU001")
Signed-off-by: Eugeniu Rosca <erosca@de.adit-jv.com>
Reviewed-by: Masahiro Yamada <yamada.masahiro@socionext.com>
Reviewed-by: Felix Brack <fb@ltec.ch>
Tested-by: Felix Brack <fb@ltec.ch>
---
 board/eets/pdu001/Kconfig | 2 +-
 1 file changed, 1 insertion(+), 1 deletion(-)

diff --git a/board/eets/pdu001/Kconfig b/board/eets/pdu001/Kconfig
index f28ba6e7bf..e64ae28875 100644
--- a/board/eets/pdu001/Kconfig
+++ b/board/eets/pdu001/Kconfig
@@ -19,7 +19,7 @@ config SYS_CONFIG_NAME
 
 choice
 	prompt "State of Run LED"
-	default PDU001_RUN_LED_RED
+	default RUN_LED_RED
 	help
 	  The PDU001 has a bi-color (red/green) LED labeled 'Run' which
 	  can be used to indicate the operating state of the board. By