power: extend prefix match to regulator-name property
This patch extends pmic_bind_children prefix matching. In addition to the node name the property regulator-name is used while trying to match prefixes. This allows assigning different drivers to regulator nodes named regulator@1 and regulator@10 for example. I have discarded the idea of using other properties then regulator-name as I do not see any benefit in using property compatible or even regulator-compatible. Of course I am open to change this if there are good reasons to do so. Signed-off-by: Felix Brack <fb@ltec.ch> Reviewed-by: Simon Glass <sjg@chromium.org>
This commit is contained in:
@@ -75,4 +75,10 @@
|
||||
regulator-min-microvolt = <3300000>;
|
||||
regulator-max-microvolt = <3300000>;
|
||||
};
|
||||
|
||||
no_match_by_nodename {
|
||||
regulator-name = "buck_SUPPLY_1.5V";
|
||||
regulator-min-microvolt = <1500000>;
|
||||
regulator-max-microvolt = <1500000>;
|
||||
};
|
||||
};
|
||||
|
||||
Reference in New Issue