binman: Avoid needing the section size in advance
Entries which include a section and need to obtain its contents call GetData(), as with any other entry. But the current implementation of this method in entry_Section requires the size of the section to be known. If it is unknown, an error is produced, since size is None: TypeError: can't multiply sequence by non-int of type 'NoneType' There is no need to know the size in advance since the code can be adjusted to build up the section piece by piece, instead of patching each entry into an existing bytearray. Update the code to handle this and add a test. Signed-off-by: Simon Glass <sjg@chromium.org>
This commit is contained in:
parent
dfdd2b6217
commit
bf4d0e2842
@ -142,13 +142,19 @@ class Entry_section(Entry):
|
||||
return self.GetEntryContents()
|
||||
|
||||
def GetData(self):
|
||||
section_data = tools.GetBytes(self._pad_byte, self.size)
|
||||
section_data = b''
|
||||
|
||||
for entry in self._entries.values():
|
||||
data = entry.GetData()
|
||||
base = self.pad_before + entry.offset - self._skip_at_start
|
||||
section_data = (section_data[:base] + data +
|
||||
section_data[base + len(data):])
|
||||
base = self.pad_before + (entry.offset or 0) - self._skip_at_start
|
||||
pad = base - len(section_data)
|
||||
if pad > 0:
|
||||
section_data += tools.GetBytes(self._pad_byte, pad)
|
||||
section_data += data
|
||||
if self.size:
|
||||
pad = self.size - len(section_data)
|
||||
if pad > 0:
|
||||
section_data += tools.GetBytes(self._pad_byte, pad)
|
||||
self.Detail('GetData: %d entries, total size %#x' %
|
||||
(len(self._entries), len(section_data)))
|
||||
return section_data
|
||||
|
@ -3321,6 +3321,12 @@ class TestFunctional(unittest.TestCase):
|
||||
expected4 = sym_values + U_BOOT_TPL_DATA[16:]
|
||||
self.assertEqual(expected4, data[upto3:])
|
||||
|
||||
def testPackX86RomIfwiSectiom(self):
|
||||
"""Test that a section can be placed in an IFWI region"""
|
||||
self._SetupIfwi('fitimage.bin')
|
||||
data = self._DoReadFile('151_x86_rom_ifwi_section.dts')
|
||||
self._CheckIfwi(data)
|
||||
|
||||
|
||||
if __name__ == "__main__":
|
||||
unittest.main()
|
||||
|
33
tools/binman/test/151_x86_rom_ifwi_section.dts
Normal file
33
tools/binman/test/151_x86_rom_ifwi_section.dts
Normal file
@ -0,0 +1,33 @@
|
||||
// SPDX-License-Identifier: GPL-2.0+
|
||||
|
||||
/dts-v1/;
|
||||
|
||||
/ {
|
||||
#address-cells = <1>;
|
||||
#size-cells = <1>;
|
||||
|
||||
binman {
|
||||
sort-by-offset;
|
||||
end-at-4gb;
|
||||
size = <0x800000>;
|
||||
intel-descriptor {
|
||||
filename = "descriptor.bin";
|
||||
};
|
||||
|
||||
intel-ifwi {
|
||||
offset-unset;
|
||||
filename = "fitimage.bin";
|
||||
convert-fit;
|
||||
|
||||
section {
|
||||
ifwi-replace;
|
||||
ifwi-subpart = "IBBP";
|
||||
ifwi-entry = "IBBL";
|
||||
u-boot-tpl {
|
||||
};
|
||||
u-boot-dtb {
|
||||
};
|
||||
};
|
||||
};
|
||||
};
|
||||
};
|
Loading…
Reference in New Issue
Block a user