serial_bcm283x_mu: Always skip init
The serial initialization doesn't always quite work for me, so let's always skip it for now. We know that firmware on the RPi initializes us properly already. Signed-off-by: Alexander Graf <agraf@suse.de>
This commit is contained in:
parent
80d5001c30
commit
bceab8d569
@ -147,7 +147,12 @@ static int bcm283x_mu_serial_ofdata_to_platdata(struct udevice *dev)
|
||||
|
||||
plat->base = addr;
|
||||
plat->clock = dev_read_u32_default(dev, "clock", 1);
|
||||
plat->skip_init = dev_read_bool(dev, "skip-init");
|
||||
|
||||
/*
|
||||
* TODO: Reinitialization doesn't always work for now, just skip
|
||||
* init always - we know we're already initialized
|
||||
*/
|
||||
plat->skip_init = true;
|
||||
|
||||
return 0;
|
||||
}
|
||||
|