trats/trats2: exynos_power_init: return 0 if no battery detected.
Generic board support is now enabled for Exynos 4, and if any init function returns an error then the init process is stopped. This makes a boot issue on the Trats and Trats2 devices. If the device is supplied by USB cable or an external power supply then it can't boot because function exynos_power_init returns an error. Now this function returns 0 if battery is not connected. Signed-off-by: Przemyslaw Marczak <p.marczak@samsung.com> Cc: Lukasz Majewski <l.majewski@samsung.com> Cc: Piotr Wilczek <p.wilczek@samsung.com> Cc: Minkyu Kang <mk7.kang@samsung.com> Signed-off-by: Minkyu Kang <mk7.kang@samsung.com>
This commit is contained in:
parent
f8caed3131
commit
4a1883651f
@ -332,7 +332,7 @@ int exynos_power_init(void)
|
||||
|
||||
if (!p_chrg->chrg->chrg_bat_present(p_chrg)) {
|
||||
puts("No battery detected\n");
|
||||
return -1;
|
||||
return 0;
|
||||
}
|
||||
|
||||
p_fg->fg->fg_battery_check(p_fg, p_bat);
|
||||
|
@ -214,7 +214,7 @@ int exynos_power_init(void)
|
||||
|
||||
if (!p_chrg->chrg->chrg_bat_present(p_chrg)) {
|
||||
puts("No battery detected\n");
|
||||
return -1;
|
||||
return 0;
|
||||
}
|
||||
|
||||
p_fg->fg->fg_battery_check(p_fg, p_bat);
|
||||
|
Loading…
Reference in New Issue
Block a user