net: introduce a helper to determine whether to use in-band autoneg
Certain serial SERDES protocols like 1000base-x, 2500base-x, SGMII, USXGMII can operate either in a mode where the PHY (be it on-board or inside an SFP module) passes the link parameters (speed, duplex, pause) to the MAC through in-band through control words standardized by IEEE 802.3 clause 37, or in a mode where the MAC must configure (force) its link parameters based on information obtained out-of-band (MDIO reads, guesswork etc). In Linux, the OF node property named "managed" is parsed by the phylink framework, and the convention is that if a driver uses phylink, then the presence of this property means that in-band autoneg should be enabled, otherwise it shouldn't. To be compatible with the OF node bindings of drivers that use phylink in Linux, introduce parsing support for this property in U-Boot too. Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com> Reviewed-by: Ramon Fried <rfried.dev@gmail.com> Reviewed-by: Bin Meng <bmeng.cn@gmail.com> Reviewed-by: Ramon Fried <rfried.dev@gmail.com>
This commit is contained in:
committed by
Ramon Fried
parent
0783b16509
commit
2dd6acb795
@@ -155,3 +155,15 @@ bool ofnode_phy_is_fixed_link(ofnode eth_node, ofnode *phy_node)
|
||||
|
||||
return true;
|
||||
}
|
||||
|
||||
bool ofnode_eth_uses_inband_aneg(ofnode eth_node)
|
||||
{
|
||||
bool inband_aneg = false;
|
||||
const char *managed;
|
||||
|
||||
managed = ofnode_read_string(eth_node, "managed");
|
||||
if (managed && !strcmp(managed, "in-band-status"))
|
||||
inband_aneg = true;
|
||||
|
||||
return inband_aneg;
|
||||
}
|
||||
|
||||
Reference in New Issue