Add a driver to control the charging algorithm used on Wilco devices. See Documentation/ABI/testing/sysfs-class-power-wilco for the userspace interface and other info. Signed-off-by: Nick Crews <ncrews@chromium.org> Reviewed-by: Enric Balletbo i Serra <enric.balletbo@collabora.com> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
		
			
				
	
	
		
			31 lines
		
	
	
		
			1.1 KiB
		
	
	
	
		
			Plaintext
		
	
	
	
	
	
			
		
		
	
	
			31 lines
		
	
	
		
			1.1 KiB
		
	
	
	
		
			Plaintext
		
	
	
	
	
	
| What:		/sys/class/power_supply/wilco-charger/charge_type
 | |
| Date:		April 2019
 | |
| KernelVersion:	5.2
 | |
| Description:
 | |
| 		What charging algorithm to use:
 | |
| 
 | |
| 		Standard: Fully charges battery at a standard rate.
 | |
| 		Adaptive: Battery settings adaptively optimized based on
 | |
| 			typical battery usage pattern.
 | |
| 		Fast: Battery charges over a shorter period.
 | |
| 		Trickle: Extends battery lifespan, intended for users who
 | |
| 			primarily use their Chromebook while connected to AC.
 | |
| 		Custom: A low and high threshold percentage is specified.
 | |
| 			Charging begins when level drops below
 | |
| 			charge_control_start_threshold, and ceases when
 | |
| 			level is above charge_control_end_threshold.
 | |
| 
 | |
| What:		/sys/class/power_supply/wilco-charger/charge_control_start_threshold
 | |
| Date:		April 2019
 | |
| KernelVersion:	5.2
 | |
| Description:
 | |
| 		Used when charge_type="Custom", as described above. Measured in
 | |
| 		percentages. The valid range is [50, 95].
 | |
| 
 | |
| What:		/sys/class/power_supply/wilco-charger/charge_control_end_threshold
 | |
| Date:		April 2019
 | |
| KernelVersion:	5.2
 | |
| Description:
 | |
| 		Used when charge_type="Custom", as described above. Measured in
 | |
| 		percentages. The valid range is [55, 100].
 |