Olof Johansson pointed out that usually the company name is picked as namespace prefix to specific properties. So expect "energymicro,location" but fall back to the previously introduced name "efm32,location". Signed-off-by: Uwe Kleine-König <u.kleine-koenig@pengutronix.de> Signed-off-by: Mark Brown <broonie@linaro.org>
		
			
				
	
	
		
			42 lines
		
	
	
		
			1.2 KiB
		
	
	
	
		
			Plaintext
		
	
	
	
	
	
			
		
		
	
	
			42 lines
		
	
	
		
			1.2 KiB
		
	
	
	
		
			Plaintext
		
	
	
	
	
	
| * Energy Micro EFM32 SPI
 | |
| 
 | |
| Required properties:
 | |
| - #address-cells: see spi-bus.txt
 | |
| - #size-cells: see spi-bus.txt
 | |
| - compatible: should be "energymicro,efm32-spi"
 | |
| - reg: Offset and length of the register set for the controller
 | |
| - interrupts: pair specifying rx and tx irq
 | |
| - clocks: phandle to the spi clock
 | |
| - cs-gpios: see spi-bus.txt
 | |
| 
 | |
| Recommended properties :
 | |
| - energymicro,location: Value to write to the ROUTE register's LOCATION
 | |
|                         bitfield to configure the pinmux for the device, see
 | |
|                         datasheet for values.
 | |
|                         If this property is not provided, keeping what is
 | |
|                         already configured in the hardware, so its either the
 | |
|                         reset default 0 or whatever the bootloader did.
 | |
| 
 | |
| Example:
 | |
| 
 | |
| spi1: spi@0x4000c400 { /* USART1 */
 | |
| 	#address-cells = <1>;
 | |
| 	#size-cells = <0>;
 | |
| 	compatible = "energymicro,efm32-spi";
 | |
| 	reg = <0x4000c400 0x400>;
 | |
| 	interrupts = <15 16>;
 | |
| 	clocks = <&cmu 20>;
 | |
| 	cs-gpios = <&gpio 51 1>; // D3
 | |
| 	energymicro,location = <1>;
 | |
| 	status = "ok";
 | |
| 
 | |
| 	ks8851@0 {
 | |
| 		compatible = "ks8851";
 | |
| 		spi-max-frequency = <6000000>;
 | |
| 		reg = <0>;
 | |
| 		interrupt-parent = <&boardfpga>;
 | |
| 		interrupts = <4>;
 | |
| 		status = "ok";
 | |
| 	};
 | |
| };
 |