linux/arch/arm64/boot/dts/rockchip/rk3368-thermal.dtsi
Caesar Wang c68bb56efb arm64: dts: rockchip: Add the thermal data found on RK3368
This patchset add the thermal for RK3368 dts,
Since the two CPU clusters, with four CPU core for each cluster,
one cluster is optimized for high-performance(big cluster) and the othe
is optimized for low power(little cluster).

This patch adds the second order for thermal throttle, and the critical
temperature for thermal over-tempeature protection on Software.

Signed-off-by: Caesar Wang <wxt@rock-chips.com>
Acked-by: Eduardo Valentin <edubezval@gmail.com>
Signed-off-by: Heiko Stuebner <heiko@sntech.de>
2015-11-21 17:35:15 +01:00

113 lines
3.5 KiB
Plaintext

/*
* Device Tree Source for RK3368 SoC thermal
*
* Copyright (c) 2015, Fuzhou Rockchip Electronics Co., Ltd
* Caesar Wang <wxt@rock-chips.com>
*
* This file is dual-licensed: you can use it either under the terms
* of the GPL or the X11 license, at your option. Note that this dual
* licensing only applies to this file, and not this project as a
* whole.
*
* a) This file is free software; you can redistribute it and/or
* modify it under the terms of the GNU General Public License as
* published by the Free Software Foundation; either version 2 of the
* License, or (at your option) any later version.
*
* This file is distributed in the hope that it will be useful,
* but WITHOUT ANY WARRANTY; without even the implied warranty of
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
* GNU General Public License for more details.
*
* Or, alternatively,
*
* b) Permission is hereby granted, free of charge, to any person
* obtaining a copy of this software and associated documentation
* files (the "Software"), to deal in the Software without
* restriction, including without limitation the rights to use,
* copy, modify, merge, publish, distribute, sublicense, and/or
* sell copies of the Software, and to permit persons to whom the
* Software is furnished to do so, subject to the following
* conditions:
*
* The above copyright notice and this permission notice shall be
* included in all copies or substantial portions of the Software.
*
* THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND,
* EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES
* OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND
* NONINFRINGEMENT. IN NO EVENT SHALL THE AUTHORS OR COPYRIGHT
* HOLDERS BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER LIABILITY,
* WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING
* FROM, OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR
* OTHER DEALINGS IN THE SOFTWARE.
*/
#include <dt-bindings/thermal/thermal.h>
cpu_thermal: cpu_thermal {
polling-delay-passive = <100>; /* milliseconds */
polling-delay = <5000>; /* milliseconds */
thermal-sensors = <&tsadc 0>;
trips {
cpu_alert0: cpu_alert0 {
temperature = <75000>; /* millicelsius */
hysteresis = <2000>; /* millicelsius */
type = "passive";
};
cpu_alert1: cpu_alert1 {
temperature = <80000>; /* millicelsius */
hysteresis = <2000>; /* millicelsius */
type = "passive";
};
cpu_crit: cpu_crit {
temperature = <95000>; /* millicelsius */
hysteresis = <2000>; /* millicelsius */
type = "critical";
};
};
cooling-maps {
map0 {
trip = <&cpu_alert0>;
cooling-device =
<&cpu_b0 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>;
};
map1 {
trip = <&cpu_alert1>;
cooling-device =
<&cpu_l0 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>;
};
};
};
gpu_thermal: gpu_thermal {
polling-delay-passive = <100>; /* milliseconds */
polling-delay = <5000>; /* milliseconds */
thermal-sensors = <&tsadc 1>;
trips {
gpu_alert0: gpu_alert0 {
temperature = <80000>; /* millicelsius */
hysteresis = <2000>; /* millicelsius */
type = "passive";
};
gpu_crit: gpu_crit {
temperature = <1150000>; /* millicelsius */
hysteresis = <2000>; /* millicelsius */
type = "critical";
};
};
cooling-maps {
map0 {
trip = <&gpu_alert0>;
cooling-device =
<&cpu_b0 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>;
};
};
};