forked from Minki/linux
1b7ddb840c
Remove tc1/tc2 in generic thermal layer. .get_trend() callback starts to take effect from this patch. Signed-off-by: Zhang Rui <rui.zhang@intel.com> Reviewed-by: Rafael J. Wysocki <rjw@sisk.pl> Reviewed-by: Valentin, Eduardo <eduardo.valentin@ti.com>
318 lines
7.3 KiB
C
318 lines
7.3 KiB
C
/*
|
|
* Universal power supply monitor class
|
|
*
|
|
* Copyright © 2007 Anton Vorontsov <cbou@mail.ru>
|
|
* Copyright © 2004 Szabolcs Gyurko
|
|
* Copyright © 2003 Ian Molton <spyro@f2s.com>
|
|
*
|
|
* Modified: 2004, Oct Szabolcs Gyurko
|
|
*
|
|
* You may use this code as per GPL version 2
|
|
*/
|
|
|
|
#include <linux/module.h>
|
|
#include <linux/types.h>
|
|
#include <linux/init.h>
|
|
#include <linux/slab.h>
|
|
#include <linux/device.h>
|
|
#include <linux/err.h>
|
|
#include <linux/power_supply.h>
|
|
#include <linux/thermal.h>
|
|
#include "power_supply.h"
|
|
|
|
/* exported for the APM Power driver, APM emulation */
|
|
struct class *power_supply_class;
|
|
EXPORT_SYMBOL_GPL(power_supply_class);
|
|
|
|
static struct device_type power_supply_dev_type;
|
|
|
|
static int __power_supply_changed_work(struct device *dev, void *data)
|
|
{
|
|
struct power_supply *psy = (struct power_supply *)data;
|
|
struct power_supply *pst = dev_get_drvdata(dev);
|
|
int i;
|
|
|
|
for (i = 0; i < psy->num_supplicants; i++)
|
|
if (!strcmp(psy->supplied_to[i], pst->name)) {
|
|
if (pst->external_power_changed)
|
|
pst->external_power_changed(pst);
|
|
}
|
|
return 0;
|
|
}
|
|
|
|
static void power_supply_changed_work(struct work_struct *work)
|
|
{
|
|
struct power_supply *psy = container_of(work, struct power_supply,
|
|
changed_work);
|
|
|
|
dev_dbg(psy->dev, "%s\n", __func__);
|
|
|
|
class_for_each_device(power_supply_class, NULL, psy,
|
|
__power_supply_changed_work);
|
|
|
|
power_supply_update_leds(psy);
|
|
|
|
kobject_uevent(&psy->dev->kobj, KOBJ_CHANGE);
|
|
}
|
|
|
|
void power_supply_changed(struct power_supply *psy)
|
|
{
|
|
dev_dbg(psy->dev, "%s\n", __func__);
|
|
|
|
schedule_work(&psy->changed_work);
|
|
}
|
|
EXPORT_SYMBOL_GPL(power_supply_changed);
|
|
|
|
static int __power_supply_am_i_supplied(struct device *dev, void *data)
|
|
{
|
|
union power_supply_propval ret = {0,};
|
|
struct power_supply *psy = (struct power_supply *)data;
|
|
struct power_supply *epsy = dev_get_drvdata(dev);
|
|
int i;
|
|
|
|
for (i = 0; i < epsy->num_supplicants; i++) {
|
|
if (!strcmp(epsy->supplied_to[i], psy->name)) {
|
|
if (epsy->get_property(epsy,
|
|
POWER_SUPPLY_PROP_ONLINE, &ret))
|
|
continue;
|
|
if (ret.intval)
|
|
return ret.intval;
|
|
}
|
|
}
|
|
return 0;
|
|
}
|
|
|
|
int power_supply_am_i_supplied(struct power_supply *psy)
|
|
{
|
|
int error;
|
|
|
|
error = class_for_each_device(power_supply_class, NULL, psy,
|
|
__power_supply_am_i_supplied);
|
|
|
|
dev_dbg(psy->dev, "%s %d\n", __func__, error);
|
|
|
|
return error;
|
|
}
|
|
EXPORT_SYMBOL_GPL(power_supply_am_i_supplied);
|
|
|
|
static int __power_supply_is_system_supplied(struct device *dev, void *data)
|
|
{
|
|
union power_supply_propval ret = {0,};
|
|
struct power_supply *psy = dev_get_drvdata(dev);
|
|
unsigned int *count = data;
|
|
|
|
(*count)++;
|
|
if (psy->type != POWER_SUPPLY_TYPE_BATTERY) {
|
|
if (psy->get_property(psy, POWER_SUPPLY_PROP_ONLINE, &ret))
|
|
return 0;
|
|
if (ret.intval)
|
|
return ret.intval;
|
|
}
|
|
return 0;
|
|
}
|
|
|
|
int power_supply_is_system_supplied(void)
|
|
{
|
|
int error;
|
|
unsigned int count = 0;
|
|
|
|
error = class_for_each_device(power_supply_class, NULL, &count,
|
|
__power_supply_is_system_supplied);
|
|
|
|
/*
|
|
* If no power class device was found at all, most probably we are
|
|
* running on a desktop system, so assume we are on mains power.
|
|
*/
|
|
if (count == 0)
|
|
return 1;
|
|
|
|
return error;
|
|
}
|
|
EXPORT_SYMBOL_GPL(power_supply_is_system_supplied);
|
|
|
|
int power_supply_set_battery_charged(struct power_supply *psy)
|
|
{
|
|
if (psy->type == POWER_SUPPLY_TYPE_BATTERY && psy->set_charged) {
|
|
psy->set_charged(psy);
|
|
return 0;
|
|
}
|
|
|
|
return -EINVAL;
|
|
}
|
|
EXPORT_SYMBOL_GPL(power_supply_set_battery_charged);
|
|
|
|
static int power_supply_match_device_by_name(struct device *dev, void *data)
|
|
{
|
|
const char *name = data;
|
|
struct power_supply *psy = dev_get_drvdata(dev);
|
|
|
|
return strcmp(psy->name, name) == 0;
|
|
}
|
|
|
|
struct power_supply *power_supply_get_by_name(char *name)
|
|
{
|
|
struct device *dev = class_find_device(power_supply_class, NULL, name,
|
|
power_supply_match_device_by_name);
|
|
|
|
return dev ? dev_get_drvdata(dev) : NULL;
|
|
}
|
|
EXPORT_SYMBOL_GPL(power_supply_get_by_name);
|
|
|
|
int power_supply_powers(struct power_supply *psy, struct device *dev)
|
|
{
|
|
return sysfs_create_link(&psy->dev->kobj, &dev->kobj, "powers");
|
|
}
|
|
EXPORT_SYMBOL_GPL(power_supply_powers);
|
|
|
|
static void power_supply_dev_release(struct device *dev)
|
|
{
|
|
pr_debug("device: '%s': %s\n", dev_name(dev), __func__);
|
|
kfree(dev);
|
|
}
|
|
|
|
#ifdef CONFIG_THERMAL
|
|
static int power_supply_read_temp(struct thermal_zone_device *tzd,
|
|
unsigned long *temp)
|
|
{
|
|
struct power_supply *psy;
|
|
union power_supply_propval val;
|
|
int ret;
|
|
|
|
WARN_ON(tzd == NULL);
|
|
psy = tzd->devdata;
|
|
ret = psy->get_property(psy, POWER_SUPPLY_PROP_TEMP, &val);
|
|
|
|
/* Convert tenths of degree Celsius to milli degree Celsius. */
|
|
if (!ret)
|
|
*temp = val.intval * 100;
|
|
|
|
return ret;
|
|
}
|
|
|
|
static struct thermal_zone_device_ops psy_tzd_ops = {
|
|
.get_temp = power_supply_read_temp,
|
|
};
|
|
|
|
static int psy_register_thermal(struct power_supply *psy)
|
|
{
|
|
int i;
|
|
|
|
/* Register battery zone device psy reports temperature */
|
|
for (i = 0; i < psy->num_properties; i++) {
|
|
if (psy->properties[i] == POWER_SUPPLY_PROP_TEMP) {
|
|
psy->tzd = thermal_zone_device_register(psy->name, 0, 0,
|
|
psy, &psy_tzd_ops, 0, 0);
|
|
if (IS_ERR(psy->tzd))
|
|
return PTR_ERR(psy->tzd);
|
|
break;
|
|
}
|
|
}
|
|
return 0;
|
|
}
|
|
|
|
static void psy_unregister_thermal(struct power_supply *psy)
|
|
{
|
|
if (IS_ERR_OR_NULL(psy->tzd))
|
|
return;
|
|
thermal_zone_device_unregister(psy->tzd);
|
|
}
|
|
#else
|
|
static int psy_register_thermal(struct power_supply *psy)
|
|
{
|
|
return 0;
|
|
}
|
|
|
|
static void psy_unregister_thermal(struct power_supply *psy)
|
|
{
|
|
}
|
|
#endif
|
|
|
|
int power_supply_register(struct device *parent, struct power_supply *psy)
|
|
{
|
|
struct device *dev;
|
|
int rc;
|
|
|
|
dev = kzalloc(sizeof(*dev), GFP_KERNEL);
|
|
if (!dev)
|
|
return -ENOMEM;
|
|
|
|
device_initialize(dev);
|
|
|
|
dev->class = power_supply_class;
|
|
dev->type = &power_supply_dev_type;
|
|
dev->parent = parent;
|
|
dev->release = power_supply_dev_release;
|
|
dev_set_drvdata(dev, psy);
|
|
psy->dev = dev;
|
|
|
|
INIT_WORK(&psy->changed_work, power_supply_changed_work);
|
|
|
|
rc = kobject_set_name(&dev->kobj, "%s", psy->name);
|
|
if (rc)
|
|
goto kobject_set_name_failed;
|
|
|
|
rc = device_add(dev);
|
|
if (rc)
|
|
goto device_add_failed;
|
|
|
|
rc = psy_register_thermal(psy);
|
|
if (rc)
|
|
goto register_thermal_failed;
|
|
|
|
rc = power_supply_create_triggers(psy);
|
|
if (rc)
|
|
goto create_triggers_failed;
|
|
|
|
power_supply_changed(psy);
|
|
|
|
goto success;
|
|
|
|
create_triggers_failed:
|
|
psy_unregister_thermal(psy);
|
|
register_thermal_failed:
|
|
device_del(dev);
|
|
kobject_set_name_failed:
|
|
device_add_failed:
|
|
put_device(dev);
|
|
success:
|
|
return rc;
|
|
}
|
|
EXPORT_SYMBOL_GPL(power_supply_register);
|
|
|
|
void power_supply_unregister(struct power_supply *psy)
|
|
{
|
|
cancel_work_sync(&psy->changed_work);
|
|
sysfs_remove_link(&psy->dev->kobj, "powers");
|
|
power_supply_remove_triggers(psy);
|
|
psy_unregister_thermal(psy);
|
|
device_unregister(psy->dev);
|
|
}
|
|
EXPORT_SYMBOL_GPL(power_supply_unregister);
|
|
|
|
static int __init power_supply_class_init(void)
|
|
{
|
|
power_supply_class = class_create(THIS_MODULE, "power_supply");
|
|
|
|
if (IS_ERR(power_supply_class))
|
|
return PTR_ERR(power_supply_class);
|
|
|
|
power_supply_class->dev_uevent = power_supply_uevent;
|
|
power_supply_init_attrs(&power_supply_dev_type);
|
|
|
|
return 0;
|
|
}
|
|
|
|
static void __exit power_supply_class_exit(void)
|
|
{
|
|
class_destroy(power_supply_class);
|
|
}
|
|
|
|
subsys_initcall(power_supply_class_init);
|
|
module_exit(power_supply_class_exit);
|
|
|
|
MODULE_DESCRIPTION("Universal power supply monitor class");
|
|
MODULE_AUTHOR("Ian Molton <spyro@f2s.com>, "
|
|
"Szabolcs Gyurko, "
|
|
"Anton Vorontsov <cbou@mail.ru>");
|
|
MODULE_LICENSE("GPL");
|