| * LM70/TMP121/LM71/LM74 thermometer.
 | |
| 
 | |
| Required properties:
 | |
| - compatible: one of
 | |
| 		"ti,lm70"
 | |
| 		"ti,tmp121"
 | |
| 		"ti,lm71"
 | |
| 		"ti,lm74"
 | |
| 
 | |
| See Documentation/devicetree/bindings/spi/spi-bus.txt for more required and
 | |
| optional properties.
 | |
| 
 | |
| Example:
 | |
| 
 | |
| spi_master {
 | |
| 	temperature-sensor@0 {
 | |
| 		compatible = "ti,lm70";
 | |
| 		reg = <0>;
 | |
| 		spi-max-frequency = <1000000>;
 | |
| 	};
 | |
| };
 |