This patch is an attempt to gather the Ethernet related bindings in one file, like it's done in the MMC and some other subsystems. It should save some of the trouble of documenting several properties over and over in each binding document, instead only making reference to the main file. I have used the Embedded Power Architecture(TM) Platform Requirements (ePAPR) standard as a base for the properties description, also documenting some ad-hoc properties that have been introduced over time despite having direct analogs in ePAPR. Signed-off-by: Sergei Shtylyov <sergei.shtylyov@cogentembedded.com> Signed-off-by: David S. Miller <davem@davemloft.net>
83 lines
2.7 KiB
Plaintext
83 lines
2.7 KiB
Plaintext
Marvell Orion/Discovery ethernet controller
|
|
=============================================
|
|
|
|
The Marvell Discovery ethernet controller can be found on Marvell Orion SoCs
|
|
(Kirkwood, Dove, Orion5x, and Discovery Innovation) and as part of Marvell
|
|
Discovery system controller chips (mv64[345]60).
|
|
|
|
The Discovery ethernet controller is described with two levels of nodes. The
|
|
first level describes the ethernet controller itself and the second level
|
|
describes up to 3 ethernet port nodes within that controller. The reason for
|
|
the multiple levels is that the port registers are interleaved within a single
|
|
set of controller registers. Each port node describes port-specific properties.
|
|
|
|
Note: The above separation is only true for Discovery system controllers.
|
|
For Orion SoCs we stick to the separation, although there each controller has
|
|
only one port associated. Multiple ports are implemented as multiple single-port
|
|
controllers. As Kirkwood has some issues with proper initialization after reset,
|
|
an extra compatible string is added for it.
|
|
|
|
* Ethernet controller node
|
|
|
|
Required controller properties:
|
|
- #address-cells: shall be 1.
|
|
- #size-cells: shall be 0.
|
|
- compatible: shall be one of "marvell,orion-eth", "marvell,kirkwood-eth".
|
|
- reg: address and length of the controller registers.
|
|
|
|
Optional controller properties:
|
|
- clocks: phandle reference to the controller clock.
|
|
- marvell,tx-checksum-limit: max tx packet size for hardware checksum.
|
|
|
|
* Ethernet port node
|
|
|
|
Required port properties:
|
|
- compatible: shall be one of "marvell,orion-eth-port",
|
|
"marvell,kirkwood-eth-port".
|
|
- reg: port number relative to ethernet controller, shall be 0, 1, or 2.
|
|
- interrupts: port interrupt.
|
|
- local-mac-address: See ethernet.txt file in the same directory.
|
|
|
|
Optional port properties:
|
|
- marvell,tx-queue-size: size of the transmit ring buffer.
|
|
- marvell,tx-sram-addr: address of transmit descriptor buffer located in SRAM.
|
|
- marvell,tx-sram-size: size of transmit descriptor buffer located in SRAM.
|
|
- marvell,rx-queue-size: size of the receive ring buffer.
|
|
- marvell,rx-sram-addr: address of receive descriptor buffer located in SRAM.
|
|
- marvell,rx-sram-size: size of receive descriptor buffer located in SRAM.
|
|
|
|
and
|
|
|
|
- phy-handle: See ethernet.txt file in the same directory.
|
|
|
|
or
|
|
|
|
- speed: port speed if no PHY connected.
|
|
- duplex: port mode if no PHY connected.
|
|
|
|
* Node example:
|
|
|
|
mdio-bus {
|
|
...
|
|
ethphy: ethernet-phy@8 {
|
|
...
|
|
};
|
|
};
|
|
|
|
eth: ethernet-controller@72000 {
|
|
compatible = "marvell,orion-eth";
|
|
#address-cells = <1>;
|
|
#size-cells = <0>;
|
|
reg = <0x72000 0x2000>;
|
|
clocks = <&gate_clk 2>;
|
|
marvell,tx-checksum-limit = <1600>;
|
|
|
|
ethernet@0 {
|
|
compatible = "marvell,orion-eth-port";
|
|
reg = <0>;
|
|
interrupts = <29>;
|
|
phy-handle = <ðphy>;
|
|
local-mac-address = [00 00 00 00 00 00];
|
|
};
|
|
};
|