The coalesce settings behave badly when changing just one value: ... # ethtool -c eth0 rx-usecs: 249 ... # ethtool -C eth0 tx-usecs 250 ... # ethtool -c eth0 rx-usecs: 248 This occurs due to rounding errors when calculating the microseconds value - the divisons round down. This causes (eg) the rx-usecs to decrease by one every time the tx-usecs value is set as per the above. Fix this by making the divison round-to-nearest. Signed-off-by: Russell King <rmk+kernel@armlinux.org.uk> Reviewed-by: Andrew Lunn <andrew@lunn.ch> Signed-off-by: David S. Miller <davem@davemloft.net> |
||
---|---|---|
.. | ||