forked from Minki/linux
3ec5f54f7a
If a IMP reset caused by some hardware errors and hns RoCE driver reset
occurred at the same time, there is a possiblity that the IMP will stop
dealing with command and users can't use the hardware. The logs are as
follows:
hns3 0000:fd:00.1: cleaned 0, need to clean 1
hns3 0000:fd:00.1: firmware version query failed -11
hns3 0000:fd:00.1: Cmd queue init failed
hns3 0000:fd:00.1: Upgrade reset level
hns3 0000:fd:00.1: global reset interrupt
The hns NIC driver divides the reset process into 3 status:
initialization, hardware resetting and softwaring restting. RoCE driver
gets reset status by interfaces provided by NIC driver and commands will
not be sent to the IMP if the driver is in any above status. The main
reason for this issue is that there is a time gap between status 1 and 2,
if the RoCE driver sends commands to the IMP during this gap, the IMP will
stop working because it is not ready.
To eliminate the time gap, the hns NIC driver has added a new interface in
commit
|
||
---|---|---|
.. | ||