forked from Minki/linux
adbfddc757
Since b9e851cd4a
("tty: n_gsm: Add some instructions and code for requester") which
introduced a warning:
linux/Documentation/driver-api/serial/n_gsm.rst:23: WARNING: Definition list ends without a blank line; unexpected unindent.
linux/Documentation/driver-api/serial/n_gsm.rst💯 WARNING: Definition list ends without a blank line; unexpected unindent.
linux/Documentation/driver-api/serial/n_gsm.rst:115: WARNING: Inline emphasis start-string without end-string.
linux/Documentation/driver-api/serial/n_gsm.rst:118: WARNING: Inline emphasis start-string without end-string.
linux/Documentation/driver-api/serial/n_gsm.rst:120: WARNING: Inline emphasis start-string without end-string.
linux/Documentation/driver-api/serial/n_gsm.rst:122: WARNING: Inline emphasis start-string without end-string.
linux/Documentation/driver-api/serial/n_gsm.rst:125: WARNING: Inline emphasis start-string without end-string.
linux/Documentation/driver-api/serial/n_gsm.rst:139: WARNING: Inline emphasis start-string without end-string.
A paragraph consisting of two colons ("::") signifies that the following text block(s) comprise a literal block.
Add soome blank lines.
Signed-off-by: Yanteng Si <siyanteng@loongson.cn>
Link: https://lore.kernel.org/r/20211209092439.562433-1-siyanteng@loongson.cn
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
160 lines
4.9 KiB
ReStructuredText
160 lines
4.9 KiB
ReStructuredText
==============================
|
|
GSM 0710 tty multiplexor HOWTO
|
|
==============================
|
|
|
|
This line discipline implements the GSM 07.10 multiplexing protocol
|
|
detailed in the following 3GPP document:
|
|
|
|
https://www.3gpp.org/ftp/Specs/archive/07_series/07.10/0710-720.zip
|
|
|
|
This document give some hints on how to use this driver with GPRS and 3G
|
|
modems connected to a physical serial port.
|
|
|
|
How to use it
|
|
-------------
|
|
1. config initiator
|
|
^^^^^^^^^^^^^^^^^^^^^
|
|
|
|
1.1 initialize the modem in 0710 mux mode (usually AT+CMUX= command) through
|
|
its serial port. Depending on the modem used, you can pass more or less
|
|
parameters to this command.
|
|
|
|
1.2 switch the serial line to using the n_gsm line discipline by using
|
|
TIOCSETD ioctl.
|
|
|
|
1.3 configure the mux using GSMIOC_GETCONF / GSMIOC_SETCONF ioctl.
|
|
|
|
1.4 obtain base gsmtty number for the used serial port.
|
|
|
|
Major parts of the initialization program :
|
|
(a good starting point is util-linux-ng/sys-utils/ldattach.c)::
|
|
|
|
#include <stdio.h>
|
|
#include <stdint.h>
|
|
#include <linux/gsmmux.h>
|
|
#include <linux/tty.h>
|
|
#define DEFAULT_SPEED B115200
|
|
#define SERIAL_PORT /dev/ttyS0
|
|
|
|
int ldisc = N_GSM0710;
|
|
struct gsm_config c;
|
|
struct termios configuration;
|
|
uint32_t first;
|
|
|
|
/* open the serial port connected to the modem */
|
|
fd = open(SERIAL_PORT, O_RDWR | O_NOCTTY | O_NDELAY);
|
|
|
|
/* configure the serial port : speed, flow control ... */
|
|
|
|
/* send the AT commands to switch the modem to CMUX mode
|
|
and check that it's successful (should return OK) */
|
|
write(fd, "AT+CMUX=0\r", 10);
|
|
|
|
/* experience showed that some modems need some time before
|
|
being able to answer to the first MUX packet so a delay
|
|
may be needed here in some case */
|
|
sleep(3);
|
|
|
|
/* use n_gsm line discipline */
|
|
ioctl(fd, TIOCSETD, &ldisc);
|
|
|
|
/* get n_gsm configuration */
|
|
ioctl(fd, GSMIOC_GETCONF, &c);
|
|
/* we are initiator and need encoding 0 (basic) */
|
|
c.initiator = 1;
|
|
c.encapsulation = 0;
|
|
/* our modem defaults to a maximum size of 127 bytes */
|
|
c.mru = 127;
|
|
c.mtu = 127;
|
|
/* set the new configuration */
|
|
ioctl(fd, GSMIOC_SETCONF, &c);
|
|
/* get first gsmtty device node */
|
|
ioctl(fd, GSMIOC_GETFIRST, &first);
|
|
printf("first muxed line: /dev/gsmtty%i\n", first);
|
|
|
|
/* and wait for ever to keep the line discipline enabled */
|
|
daemon(0,0);
|
|
pause();
|
|
|
|
1.5 use these devices as plain serial ports.
|
|
|
|
for example, it's possible:
|
|
|
|
- and to use gnokii to send / receive SMS on ttygsm1
|
|
- to use ppp to establish a datalink on ttygsm2
|
|
|
|
1.6 first close all virtual ports before closing the physical port.
|
|
|
|
Note that after closing the physical port the modem is still in multiplexing
|
|
mode. This may prevent a successful re-opening of the port later. To avoid
|
|
this situation either reset the modem if your hardware allows that or send
|
|
a disconnect command frame manually before initializing the multiplexing mode
|
|
for the second time. The byte sequence for the disconnect command frame is::
|
|
|
|
0xf9, 0x03, 0xef, 0x03, 0xc3, 0x16, 0xf9.
|
|
|
|
2. config requester
|
|
^^^^^^^^^^^^^^^^^^^^^
|
|
|
|
2.1 receive string "AT+CMUX= command" through its serial port,initialize
|
|
mux mode config
|
|
|
|
2.2 switch the serial line to using the n_gsm line discipline by using
|
|
TIOCSETD ioctl.
|
|
|
|
2.3 configure the mux using GSMIOC_GETCONF / GSMIOC_SETCONF ioctl.
|
|
|
|
2.4 obtain base gsmtty number for the used serial port::
|
|
|
|
#include <stdio.h>
|
|
#include <stdint.h>
|
|
#include <linux/gsmmux.h>
|
|
#include <linux/tty.h>
|
|
#define DEFAULT_SPEED B115200
|
|
#define SERIAL_PORT /dev/ttyS0
|
|
|
|
int ldisc = N_GSM0710;
|
|
struct gsm_config c;
|
|
struct termios configuration;
|
|
uint32_t first;
|
|
|
|
/* open the serial port */
|
|
fd = open(SERIAL_PORT, O_RDWR | O_NOCTTY | O_NDELAY);
|
|
|
|
/* configure the serial port : speed, flow control ... */
|
|
|
|
/* get serial data and check "AT+CMUX=command" parameter ... */
|
|
|
|
/* use n_gsm line discipline */
|
|
ioctl(fd, TIOCSETD, &ldisc);
|
|
|
|
/* get n_gsm configuration */
|
|
ioctl(fd, GSMIOC_GETCONF, &c);
|
|
/* we are requester and need encoding 0 (basic) */
|
|
c.initiator = 0;
|
|
c.encapsulation = 0;
|
|
/* our modem defaults to a maximum size of 127 bytes */
|
|
c.mru = 127;
|
|
c.mtu = 127;
|
|
/* set the new configuration */
|
|
ioctl(fd, GSMIOC_SETCONF, &c);
|
|
/* get first gsmtty device node */
|
|
ioctl(fd, GSMIOC_GETFIRST, &first);
|
|
printf("first muxed line: /dev/gsmtty%i\n", first);
|
|
|
|
/* and wait for ever to keep the line discipline enabled */
|
|
daemon(0,0);
|
|
pause();
|
|
|
|
Additional Documentation
|
|
------------------------
|
|
More practical details on the protocol and how it's supported by industrial
|
|
modems can be found in the following documents :
|
|
|
|
- http://www.telit.com/module/infopool/download.php?id=616
|
|
- http://www.u-blox.com/images/downloads/Product_Docs/LEON-G100-G200-MuxImplementation_ApplicationNote_%28GSM%20G1-CS-10002%29.pdf
|
|
- http://www.sierrawireless.com/Support/Downloads/AirPrime/WMP_Series/~/media/Support_Downloads/AirPrime/Application_notes/CMUX_Feature_Application_Note-Rev004.ashx
|
|
- http://wm.sim.com/sim/News/photo/2010721161442.pdf
|
|
|
|
11-03-08 - Eric Bénard - <eric@eukrea.com>
|