linux/drivers/pci
Mika Westerberg 3374c545c2 PCI: Account for all bridges on bus when distributing bus numbers
When distributing extra bus number space to hotplug bridges for future
extension, we don't account for the fact that there might be non-hotplug
bridges on the bus after the hotplug bridges.  For example:

  01:00.0 --+- 02:00.0 (HotPlug-) -- Thunderbolt host controller
            +- 02:01.0 (HotPlug+)
            \- 02:02.0 (HotPlug-) -- xHCI host controller

pci_scan_child_bus_extend() is supposed to distribute the remaining bus
numbers to the hotplug bridge at 02:01.0, but only after accounting for all
bridges on bus 02.  Since we don't check whether there's another
non-hotplug bridge after the hotplug bridge 02:01.0, it may not leave space
for the non-hotplug bridge:

  pci 0000:00:1b.0: PCI bridge to [bus 01-39]  (Root Port)
  pci 0000:01:00.0: PCI bridge to [bus 02-39]
  ...
  pci 0000:02:00.0: PCI bridge to [bus 03]
  pci 0000:02:01.0: PCI bridge to [bus 04]
  pci_bus 0000:04: [bus 04-39] extended by 0x35
  pci_bus 0000:04: bus scan returning with max=39
  pci_bus 0000:04: busn_res: [bus 04-39] end is updated to 39
  pci 0000:02:02.0: scanning [bus 00-00] behind bridge, pass 1
  pci_bus 0000:3a: scanning bus
  pci_bus 0000:3a: bus scan returning with max=3a
  pci_bus 0000:3a: busn_res: [bus 3a] end is updated to 3a
  pci_bus 0000:3a: [bus 3a] partially hidden behind bridge 0000:02 [bus 02-39]
  pci_bus 0000:3a: [bus 3a] partially hidden behind bridge 0000:01 [bus 01-39]
  pci_bus 0000:02: bus scan returning with max=3a
  pci_bus 0000:02: busn_res: [bus 02-39] end can not be updated to 3a

The resulting 'lspci -t' output looks like this:

  +-1b.0-[01-39]----00.0-[02-3a]--+-00.0-[03]----00.0
                             ^^   +-01.0-[04-39]--
                                  \-02.0-[3a]----00.0
                                          ^^
The xHCI host controller behind 02:02.0 is not usable because it would have
to be assigned bus 3a, which is not accessible through 00:1b.0.

To fix this, reserve at least one bus for each bridge while scanning
already configured bridges.  Then use this information in the second
scan to correct the available extra bus space for hotplug bridges.

After this change the 'lspci -t' output is what is expected:

  +-1b.0-[01-39]----00.0-[02-39]--+-00.0-[03]----00.0
                                  +-01.0-[04-38]--
                                  \-02.0-[39]----00.0

The xHCI controller is now on bus 39, where it is usable.

Fixes: 1c02ea8100 ("PCI: Distribute available buses to hotplug-capable bridges")
Reported-by: Mario Limonciello <mario.limonciello@dell.com>
Signed-off-by: Mika Westerberg <mika.westerberg@linux.intel.com>
[bhelgaas: changelog]
Signed-off-by: Bjorn Helgaas <bhelgaas@google.com>
Reviewed-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
Reviewed-by: Andy Shevchenko <andriy.shevchenko@linux.intel.com>
Cc: stable@vger.kernel.org
2018-06-04 12:08:06 -05:00
..
cadence PCI: endpoint: Make epc->ops->clear_bar()/pci_epc_clear_bar() take struct *epf_bar 2018-04-03 12:38:05 +01:00
dwc pci-v4.17-changes 2018-04-06 18:31:06 -07:00
endpoint PCI: endpoint: Make sure that BAR_5 does not have 64-bit flag set when clearing 2018-04-03 12:38:05 +01:00
host Merge branch 'lorenzo/pci/xilinx' 2018-04-04 13:28:57 -05:00
hotplug ACPI / hotplug / PCI: Drop unnecessary parentheses 2018-06-04 12:08:06 -05:00
pcie PCI: pciehp: Make pciehp_is_native() stricter 2018-06-02 00:18:28 -05:00
switch vfs: do bulk POLL* -> EPOLL* replacement 2018-02-11 14:34:03 -08:00
access.c Merge branch 'pci/vpd' 2018-04-04 13:28:40 -05:00
ats.c PCI: Tidy comments 2018-03-19 14:20:43 -05:00
bus.c PCI: Tidy comments 2018-03-19 14:20:43 -05:00
ecam.c PCI: Add SPDX GPL-2.0 to replace GPL v2 boilerplate 2018-01-28 15:48:29 -06:00
host-bridge.c PCI: Tidy comments 2018-03-19 14:20:43 -05:00
iov.c Merge branch 'pci/virtualization' 2018-04-04 13:28:26 -05:00
irq.c PCI: Add wrappers for dev_printk() 2018-01-18 12:55:24 -06:00
Kconfig Merge branch 'pci/spdx' into next 2018-02-01 11:40:07 -06:00
Makefile PCI: Tidy Makefiles 2018-03-19 14:20:41 -05:00
mmap.c PCI: Tidy comments 2018-03-19 14:20:43 -05:00
msi.c PCI: Tidy comments 2018-03-19 14:20:43 -05:00
of.c Merge branch 'pci/spdx' into next 2018-02-01 11:40:07 -06:00
pci-acpi.c PCI: shpchp: Add shpchp_is_native() 2018-06-04 12:08:06 -05:00
pci-driver.c pci-v4.17-changes 2018-04-06 18:31:06 -07:00
pci-label.c PCI: Tidy comments 2018-03-19 14:20:43 -05:00
pci-mid.c PCI: Add SPDX GPL-2.0 to replace GPL v2 boilerplate 2018-01-28 15:48:29 -06:00
pci-stub.c PCI: Tidy comments 2018-03-19 14:20:43 -05:00
pci-sysfs.c Merge branch 'pci/vpd' 2018-04-04 13:28:40 -05:00
pci.c PCI: Remove messages about reassigning resources 2018-04-11 08:46:50 -05:00
pci.h Merge branch 'pci/vpd' 2018-04-04 13:28:40 -05:00
probe.c PCI: Account for all bridges on bus when distributing bus numbers 2018-06-04 12:08:06 -05:00
proc.c PCI: Tidy comments 2018-03-19 14:20:43 -05:00
quirks.c PCI: Add Qualcomm vendor ID 2018-05-07 15:52:55 -05:00
remove.c PCI: Add SPDX GPL-2.0 when no license was specified 2018-01-26 11:45:16 -06:00
rom.c PCI: Tidy comments 2018-03-19 14:20:43 -05:00
search.c PCI: Tidy comments 2018-03-19 14:20:43 -05:00
setup-bus.c PCI: Tidy comments 2018-03-19 14:20:43 -05:00
setup-irq.c PCI: Tidy comments 2018-03-19 14:20:43 -05:00
setup-res.c PCI: Remove messages about reassigning resources 2018-04-11 08:46:50 -05:00
slot.c Merge branch 'pci/misc' 2018-04-04 13:27:45 -05:00
syscall.c PCI: Tidy comments 2018-03-19 14:20:43 -05:00
vc.c Merge branch 'pci/spdx' into next 2018-02-01 11:40:07 -06:00
vpd.c pci-v4.17-changes 2018-04-06 18:31:06 -07:00
xen-pcifront.c PCI: Tidy comments 2018-03-19 14:20:43 -05:00