forked from Minki/linux
132b16325f
In d7e81c2
(clocksource: Add clocksource_register_hz/khz interface) new
interfaces were added which simplify (and optimize) the selection of the
divisor shift/mult constants. Switch over to using this new interface.
Acked-by: Jean-Christophe PLAGNIOL-VILLARD <plagnioj@jcrosoft.com>
Signed-off-by: Russell King <rmk+kernel@arm.linux.org.uk>
189 lines
4.7 KiB
C
189 lines
4.7 KiB
C
/*
|
|
* at91sam926x_time.c - Periodic Interval Timer (PIT) for at91sam926x
|
|
*
|
|
* Copyright (C) 2005-2006 M. Amine SAYA, ATMEL Rousset, France
|
|
* Revision 2005 M. Nicolas Diremdjian, ATMEL Rousset, France
|
|
* Converted to ClockSource/ClockEvents by David Brownell.
|
|
*
|
|
* This program is free software; you can redistribute it and/or modify
|
|
* it under the terms of the GNU General Public License version 2 as
|
|
* published by the Free Software Foundation.
|
|
*/
|
|
#include <linux/interrupt.h>
|
|
#include <linux/irq.h>
|
|
#include <linux/kernel.h>
|
|
#include <linux/clk.h>
|
|
#include <linux/clockchips.h>
|
|
|
|
#include <asm/mach/time.h>
|
|
|
|
#include <mach/at91_pit.h>
|
|
|
|
|
|
#define PIT_CPIV(x) ((x) & AT91_PIT_CPIV)
|
|
#define PIT_PICNT(x) (((x) & AT91_PIT_PICNT) >> 20)
|
|
|
|
static u32 pit_cycle; /* write-once */
|
|
static u32 pit_cnt; /* access only w/system irq blocked */
|
|
|
|
|
|
/*
|
|
* Clocksource: just a monotonic counter of MCK/16 cycles.
|
|
* We don't care whether or not PIT irqs are enabled.
|
|
*/
|
|
static cycle_t read_pit_clk(struct clocksource *cs)
|
|
{
|
|
unsigned long flags;
|
|
u32 elapsed;
|
|
u32 t;
|
|
|
|
raw_local_irq_save(flags);
|
|
elapsed = pit_cnt;
|
|
t = at91_sys_read(AT91_PIT_PIIR);
|
|
raw_local_irq_restore(flags);
|
|
|
|
elapsed += PIT_PICNT(t) * pit_cycle;
|
|
elapsed += PIT_CPIV(t);
|
|
return elapsed;
|
|
}
|
|
|
|
static struct clocksource pit_clk = {
|
|
.name = "pit",
|
|
.rating = 175,
|
|
.read = read_pit_clk,
|
|
.flags = CLOCK_SOURCE_IS_CONTINUOUS,
|
|
};
|
|
|
|
|
|
/*
|
|
* Clockevent device: interrupts every 1/HZ (== pit_cycles * MCK/16)
|
|
*/
|
|
static void
|
|
pit_clkevt_mode(enum clock_event_mode mode, struct clock_event_device *dev)
|
|
{
|
|
switch (mode) {
|
|
case CLOCK_EVT_MODE_PERIODIC:
|
|
/* update clocksource counter */
|
|
pit_cnt += pit_cycle * PIT_PICNT(at91_sys_read(AT91_PIT_PIVR));
|
|
at91_sys_write(AT91_PIT_MR, (pit_cycle - 1) | AT91_PIT_PITEN
|
|
| AT91_PIT_PITIEN);
|
|
break;
|
|
case CLOCK_EVT_MODE_ONESHOT:
|
|
BUG();
|
|
/* FALLTHROUGH */
|
|
case CLOCK_EVT_MODE_SHUTDOWN:
|
|
case CLOCK_EVT_MODE_UNUSED:
|
|
/* disable irq, leaving the clocksource active */
|
|
at91_sys_write(AT91_PIT_MR, (pit_cycle - 1) | AT91_PIT_PITEN);
|
|
break;
|
|
case CLOCK_EVT_MODE_RESUME:
|
|
break;
|
|
}
|
|
}
|
|
|
|
static struct clock_event_device pit_clkevt = {
|
|
.name = "pit",
|
|
.features = CLOCK_EVT_FEAT_PERIODIC,
|
|
.shift = 32,
|
|
.rating = 100,
|
|
.set_mode = pit_clkevt_mode,
|
|
};
|
|
|
|
|
|
/*
|
|
* IRQ handler for the timer.
|
|
*/
|
|
static irqreturn_t at91sam926x_pit_interrupt(int irq, void *dev_id)
|
|
{
|
|
/*
|
|
* irqs should be disabled here, but as the irq is shared they are only
|
|
* guaranteed to be off if the timer irq is registered first.
|
|
*/
|
|
WARN_ON_ONCE(!irqs_disabled());
|
|
|
|
/* The PIT interrupt may be disabled, and is shared */
|
|
if ((pit_clkevt.mode == CLOCK_EVT_MODE_PERIODIC)
|
|
&& (at91_sys_read(AT91_PIT_SR) & AT91_PIT_PITS)) {
|
|
unsigned nr_ticks;
|
|
|
|
/* Get number of ticks performed before irq, and ack it */
|
|
nr_ticks = PIT_PICNT(at91_sys_read(AT91_PIT_PIVR));
|
|
do {
|
|
pit_cnt += pit_cycle;
|
|
pit_clkevt.event_handler(&pit_clkevt);
|
|
nr_ticks--;
|
|
} while (nr_ticks);
|
|
|
|
return IRQ_HANDLED;
|
|
}
|
|
|
|
return IRQ_NONE;
|
|
}
|
|
|
|
static struct irqaction at91sam926x_pit_irq = {
|
|
.name = "at91_tick",
|
|
.flags = IRQF_SHARED | IRQF_DISABLED | IRQF_TIMER | IRQF_IRQPOLL,
|
|
.handler = at91sam926x_pit_interrupt
|
|
};
|
|
|
|
static void at91sam926x_pit_reset(void)
|
|
{
|
|
/* Disable timer and irqs */
|
|
at91_sys_write(AT91_PIT_MR, 0);
|
|
|
|
/* Clear any pending interrupts, wait for PIT to stop counting */
|
|
while (PIT_CPIV(at91_sys_read(AT91_PIT_PIVR)) != 0)
|
|
cpu_relax();
|
|
|
|
/* Start PIT but don't enable IRQ */
|
|
at91_sys_write(AT91_PIT_MR, (pit_cycle - 1) | AT91_PIT_PITEN);
|
|
}
|
|
|
|
/*
|
|
* Set up both clocksource and clockevent support.
|
|
*/
|
|
static void __init at91sam926x_pit_init(void)
|
|
{
|
|
unsigned long pit_rate;
|
|
unsigned bits;
|
|
|
|
/*
|
|
* Use our actual MCK to figure out how many MCK/16 ticks per
|
|
* 1/HZ period (instead of a compile-time constant LATCH).
|
|
*/
|
|
pit_rate = clk_get_rate(clk_get(NULL, "mck")) / 16;
|
|
pit_cycle = (pit_rate + HZ/2) / HZ;
|
|
WARN_ON(((pit_cycle - 1) & ~AT91_PIT_PIV) != 0);
|
|
|
|
/* Initialize and enable the timer */
|
|
at91sam926x_pit_reset();
|
|
|
|
/*
|
|
* Register clocksource. The high order bits of PIV are unused,
|
|
* so this isn't a 32-bit counter unless we get clockevent irqs.
|
|
*/
|
|
bits = 12 /* PICNT */ + ilog2(pit_cycle) /* PIV */;
|
|
pit_clk.mask = CLOCKSOURCE_MASK(bits);
|
|
clocksource_register_hz(&pit_clk, pit_rate);
|
|
|
|
/* Set up irq handler */
|
|
setup_irq(AT91_ID_SYS, &at91sam926x_pit_irq);
|
|
|
|
/* Set up and register clockevents */
|
|
pit_clkevt.mult = div_sc(pit_rate, NSEC_PER_SEC, pit_clkevt.shift);
|
|
pit_clkevt.cpumask = cpumask_of(0);
|
|
clockevents_register_device(&pit_clkevt);
|
|
}
|
|
|
|
static void at91sam926x_pit_suspend(void)
|
|
{
|
|
/* Disable timer */
|
|
at91_sys_write(AT91_PIT_MR, 0);
|
|
}
|
|
|
|
struct sys_timer at91sam926x_timer = {
|
|
.init = at91sam926x_pit_init,
|
|
.suspend = at91sam926x_pit_suspend,
|
|
.resume = at91sam926x_pit_reset,
|
|
};
|