forked from Minki/linux
0015d9a2a7
Bang-bang governor source file is prefixed with gov_. Do the same for other governors for consistency so they're easy to find in the sources. Signed-off-by: Amit Kucheria <amit.kucheria@linaro.org> Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org> Link: https://lore.kernel.org/r/b9a85d3204712f14e320504948c12712dc0b291b.1589199124.git.amit.kucheria@linaro.org
121 lines
3.3 KiB
C
121 lines
3.3 KiB
C
// SPDX-License-Identifier: GPL-2.0-only
|
|
/*
|
|
* fair_share.c - A simple weight based Thermal governor
|
|
*
|
|
* Copyright (C) 2012 Intel Corp
|
|
* Copyright (C) 2012 Durgadoss R <durgadoss.r@intel.com>
|
|
*
|
|
* ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
*
|
|
* ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
*/
|
|
|
|
#include <linux/thermal.h>
|
|
#include <trace/events/thermal.h>
|
|
|
|
#include "thermal_core.h"
|
|
|
|
/**
|
|
* get_trip_level: - obtains the current trip level for a zone
|
|
* @tz: thermal zone device
|
|
*/
|
|
static int get_trip_level(struct thermal_zone_device *tz)
|
|
{
|
|
int count = 0;
|
|
int trip_temp;
|
|
enum thermal_trip_type trip_type;
|
|
|
|
if (tz->trips == 0 || !tz->ops->get_trip_temp)
|
|
return 0;
|
|
|
|
for (count = 0; count < tz->trips; count++) {
|
|
tz->ops->get_trip_temp(tz, count, &trip_temp);
|
|
if (tz->temperature < trip_temp)
|
|
break;
|
|
}
|
|
|
|
/*
|
|
* count > 0 only if temperature is greater than first trip
|
|
* point, in which case, trip_point = count - 1
|
|
*/
|
|
if (count > 0) {
|
|
tz->ops->get_trip_type(tz, count - 1, &trip_type);
|
|
trace_thermal_zone_trip(tz, count - 1, trip_type);
|
|
}
|
|
|
|
return count;
|
|
}
|
|
|
|
static long get_target_state(struct thermal_zone_device *tz,
|
|
struct thermal_cooling_device *cdev, int percentage, int level)
|
|
{
|
|
unsigned long max_state;
|
|
|
|
cdev->ops->get_max_state(cdev, &max_state);
|
|
|
|
return (long)(percentage * level * max_state) / (100 * tz->trips);
|
|
}
|
|
|
|
/**
|
|
* fair_share_throttle - throttles devices associated with the given zone
|
|
* @tz: thermal_zone_device
|
|
* @trip: trip point index
|
|
*
|
|
* Throttling Logic: This uses three parameters to calculate the new
|
|
* throttle state of the cooling devices associated with the given zone.
|
|
*
|
|
* Parameters used for Throttling:
|
|
* P1. max_state: Maximum throttle state exposed by the cooling device.
|
|
* P2. percentage[i]/100:
|
|
* How 'effective' the 'i'th device is, in cooling the given zone.
|
|
* P3. cur_trip_level/max_no_of_trips:
|
|
* This describes the extent to which the devices should be throttled.
|
|
* We do not want to throttle too much when we trip a lower temperature,
|
|
* whereas the throttling is at full swing if we trip critical levels.
|
|
* (Heavily assumes the trip points are in ascending order)
|
|
* new_state of cooling device = P3 * P2 * P1
|
|
*/
|
|
static int fair_share_throttle(struct thermal_zone_device *tz, int trip)
|
|
{
|
|
struct thermal_instance *instance;
|
|
int total_weight = 0;
|
|
int total_instance = 0;
|
|
int cur_trip_level = get_trip_level(tz);
|
|
|
|
list_for_each_entry(instance, &tz->thermal_instances, tz_node) {
|
|
if (instance->trip != trip)
|
|
continue;
|
|
|
|
total_weight += instance->weight;
|
|
total_instance++;
|
|
}
|
|
|
|
list_for_each_entry(instance, &tz->thermal_instances, tz_node) {
|
|
int percentage;
|
|
struct thermal_cooling_device *cdev = instance->cdev;
|
|
|
|
if (instance->trip != trip)
|
|
continue;
|
|
|
|
if (!total_weight)
|
|
percentage = 100 / total_instance;
|
|
else
|
|
percentage = (instance->weight * 100) / total_weight;
|
|
|
|
instance->target = get_target_state(tz, cdev, percentage,
|
|
cur_trip_level);
|
|
|
|
mutex_lock(&instance->cdev->lock);
|
|
instance->cdev->updated = false;
|
|
mutex_unlock(&instance->cdev->lock);
|
|
thermal_cdev_update(cdev);
|
|
}
|
|
return 0;
|
|
}
|
|
|
|
static struct thermal_governor thermal_gov_fair_share = {
|
|
.name = "fair_share",
|
|
.throttle = fair_share_throttle,
|
|
};
|
|
THERMAL_GOVERNOR_DECLARE(thermal_gov_fair_share);
|