When the termios CIBAUD bits are left unset (i.e. B0), we use the same
output and input speed and should leave CIBAUD unchanged.
When the user requests a rate using BOTHER and c_ospeed which the driver
cannot set exactly, the driver can report back the actual baud rate
using tty_termios_encode_baud_rate(). If this rate is close enough to a
standard rate however, we could end up setting CIBAUD to a Bfoo value
despite the user having left it unset.
This in turn could lead to an unexpected input rate being set on
subsequent termios updates.
Fix this by using a zero tolerance value also for the input rate when
CIBAUD is clear so that the matching logic works as expected.
Fixes: 78137e3b34 ("[PATCH] tty: improve encode_baud_rate logic")
Signed-off-by: Johan Hovold <johan@kernel.org>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>