forked from Minki/linux
f232168df0
regulator_enable_regmap() uses enable_reg to enable the regulator. But enable_reg for smps10 points to SMPS10_STATUS which is a read-only register. Fixed the same by having enable_reg set to SMPS10_CTRL. Signed-off-by: Kishon Vijay Abraham I <kishon@ti.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com> Cc: stable@vger.kernel.org
1084 lines
26 KiB
C
1084 lines
26 KiB
C
/*
|
|
* Driver for Regulator part of Palmas PMIC Chips
|
|
*
|
|
* Copyright 2011-2013 Texas Instruments Inc.
|
|
*
|
|
* Author: Graeme Gregory <gg@slimlogic.co.uk>
|
|
* Author: Ian Lartey <ian@slimlogic.co.uk>
|
|
*
|
|
* This program is free software; you can redistribute it and/or modify it
|
|
* under the terms of the GNU General Public License as published by the
|
|
* Free Software Foundation; either version 2 of the License, or (at your
|
|
* option) any later version.
|
|
*
|
|
*/
|
|
|
|
#include <linux/kernel.h>
|
|
#include <linux/module.h>
|
|
#include <linux/init.h>
|
|
#include <linux/err.h>
|
|
#include <linux/platform_device.h>
|
|
#include <linux/regulator/driver.h>
|
|
#include <linux/regulator/machine.h>
|
|
#include <linux/slab.h>
|
|
#include <linux/regmap.h>
|
|
#include <linux/mfd/palmas.h>
|
|
#include <linux/of.h>
|
|
#include <linux/of_platform.h>
|
|
#include <linux/regulator/of_regulator.h>
|
|
|
|
struct regs_info {
|
|
char *name;
|
|
char *sname;
|
|
u8 vsel_addr;
|
|
u8 ctrl_addr;
|
|
u8 tstep_addr;
|
|
};
|
|
|
|
static const struct regs_info palmas_regs_info[] = {
|
|
{
|
|
.name = "SMPS12",
|
|
.sname = "smps1-in",
|
|
.vsel_addr = PALMAS_SMPS12_VOLTAGE,
|
|
.ctrl_addr = PALMAS_SMPS12_CTRL,
|
|
.tstep_addr = PALMAS_SMPS12_TSTEP,
|
|
},
|
|
{
|
|
.name = "SMPS123",
|
|
.sname = "smps1-in",
|
|
.vsel_addr = PALMAS_SMPS12_VOLTAGE,
|
|
.ctrl_addr = PALMAS_SMPS12_CTRL,
|
|
.tstep_addr = PALMAS_SMPS12_TSTEP,
|
|
},
|
|
{
|
|
.name = "SMPS3",
|
|
.sname = "smps3-in",
|
|
.vsel_addr = PALMAS_SMPS3_VOLTAGE,
|
|
.ctrl_addr = PALMAS_SMPS3_CTRL,
|
|
},
|
|
{
|
|
.name = "SMPS45",
|
|
.sname = "smps4-in",
|
|
.vsel_addr = PALMAS_SMPS45_VOLTAGE,
|
|
.ctrl_addr = PALMAS_SMPS45_CTRL,
|
|
.tstep_addr = PALMAS_SMPS45_TSTEP,
|
|
},
|
|
{
|
|
.name = "SMPS457",
|
|
.sname = "smps4-in",
|
|
.vsel_addr = PALMAS_SMPS45_VOLTAGE,
|
|
.ctrl_addr = PALMAS_SMPS45_CTRL,
|
|
.tstep_addr = PALMAS_SMPS45_TSTEP,
|
|
},
|
|
{
|
|
.name = "SMPS6",
|
|
.sname = "smps6-in",
|
|
.vsel_addr = PALMAS_SMPS6_VOLTAGE,
|
|
.ctrl_addr = PALMAS_SMPS6_CTRL,
|
|
.tstep_addr = PALMAS_SMPS6_TSTEP,
|
|
},
|
|
{
|
|
.name = "SMPS7",
|
|
.sname = "smps7-in",
|
|
.vsel_addr = PALMAS_SMPS7_VOLTAGE,
|
|
.ctrl_addr = PALMAS_SMPS7_CTRL,
|
|
},
|
|
{
|
|
.name = "SMPS8",
|
|
.sname = "smps8-in",
|
|
.vsel_addr = PALMAS_SMPS8_VOLTAGE,
|
|
.ctrl_addr = PALMAS_SMPS8_CTRL,
|
|
.tstep_addr = PALMAS_SMPS8_TSTEP,
|
|
},
|
|
{
|
|
.name = "SMPS9",
|
|
.sname = "smps9-in",
|
|
.vsel_addr = PALMAS_SMPS9_VOLTAGE,
|
|
.ctrl_addr = PALMAS_SMPS9_CTRL,
|
|
},
|
|
{
|
|
.name = "SMPS10",
|
|
.sname = "smps10-in",
|
|
.ctrl_addr = PALMAS_SMPS10_CTRL,
|
|
},
|
|
{
|
|
.name = "LDO1",
|
|
.sname = "ldo1-in",
|
|
.vsel_addr = PALMAS_LDO1_VOLTAGE,
|
|
.ctrl_addr = PALMAS_LDO1_CTRL,
|
|
},
|
|
{
|
|
.name = "LDO2",
|
|
.sname = "ldo2-in",
|
|
.vsel_addr = PALMAS_LDO2_VOLTAGE,
|
|
.ctrl_addr = PALMAS_LDO2_CTRL,
|
|
},
|
|
{
|
|
.name = "LDO3",
|
|
.sname = "ldo3-in",
|
|
.vsel_addr = PALMAS_LDO3_VOLTAGE,
|
|
.ctrl_addr = PALMAS_LDO3_CTRL,
|
|
},
|
|
{
|
|
.name = "LDO4",
|
|
.sname = "ldo4-in",
|
|
.vsel_addr = PALMAS_LDO4_VOLTAGE,
|
|
.ctrl_addr = PALMAS_LDO4_CTRL,
|
|
},
|
|
{
|
|
.name = "LDO5",
|
|
.sname = "ldo5-in",
|
|
.vsel_addr = PALMAS_LDO5_VOLTAGE,
|
|
.ctrl_addr = PALMAS_LDO5_CTRL,
|
|
},
|
|
{
|
|
.name = "LDO6",
|
|
.sname = "ldo6-in",
|
|
.vsel_addr = PALMAS_LDO6_VOLTAGE,
|
|
.ctrl_addr = PALMAS_LDO6_CTRL,
|
|
},
|
|
{
|
|
.name = "LDO7",
|
|
.sname = "ldo7-in",
|
|
.vsel_addr = PALMAS_LDO7_VOLTAGE,
|
|
.ctrl_addr = PALMAS_LDO7_CTRL,
|
|
},
|
|
{
|
|
.name = "LDO8",
|
|
.sname = "ldo8-in",
|
|
.vsel_addr = PALMAS_LDO8_VOLTAGE,
|
|
.ctrl_addr = PALMAS_LDO8_CTRL,
|
|
},
|
|
{
|
|
.name = "LDO9",
|
|
.sname = "ldo9-in",
|
|
.vsel_addr = PALMAS_LDO9_VOLTAGE,
|
|
.ctrl_addr = PALMAS_LDO9_CTRL,
|
|
},
|
|
{
|
|
.name = "LDOLN",
|
|
.sname = "ldoln-in",
|
|
.vsel_addr = PALMAS_LDOLN_VOLTAGE,
|
|
.ctrl_addr = PALMAS_LDOLN_CTRL,
|
|
},
|
|
{
|
|
.name = "LDOUSB",
|
|
.sname = "ldousb-in",
|
|
.vsel_addr = PALMAS_LDOUSB_VOLTAGE,
|
|
.ctrl_addr = PALMAS_LDOUSB_CTRL,
|
|
},
|
|
{
|
|
.name = "REGEN1",
|
|
.ctrl_addr = PALMAS_REGEN1_CTRL,
|
|
},
|
|
{
|
|
.name = "REGEN2",
|
|
.ctrl_addr = PALMAS_REGEN2_CTRL,
|
|
},
|
|
{
|
|
.name = "REGEN3",
|
|
.ctrl_addr = PALMAS_REGEN3_CTRL,
|
|
},
|
|
{
|
|
.name = "SYSEN1",
|
|
.ctrl_addr = PALMAS_SYSEN1_CTRL,
|
|
},
|
|
{
|
|
.name = "SYSEN2",
|
|
.ctrl_addr = PALMAS_SYSEN2_CTRL,
|
|
},
|
|
};
|
|
|
|
static unsigned int palmas_smps_ramp_delay[4] = {0, 10000, 5000, 2500};
|
|
|
|
#define SMPS_CTRL_MODE_OFF 0x00
|
|
#define SMPS_CTRL_MODE_ON 0x01
|
|
#define SMPS_CTRL_MODE_ECO 0x02
|
|
#define SMPS_CTRL_MODE_PWM 0x03
|
|
|
|
/* These values are derived from the data sheet. And are the number of steps
|
|
* where there is a voltage change, the ranges at beginning and end of register
|
|
* max/min values where there are no change are ommitted.
|
|
*
|
|
* So they are basically (maxV-minV)/stepV
|
|
*/
|
|
#define PALMAS_SMPS_NUM_VOLTAGES 117
|
|
#define PALMAS_SMPS10_NUM_VOLTAGES 2
|
|
#define PALMAS_LDO_NUM_VOLTAGES 50
|
|
|
|
#define SMPS10_VSEL (1<<3)
|
|
#define SMPS10_BOOST_EN (1<<2)
|
|
#define SMPS10_BYPASS_EN (1<<1)
|
|
#define SMPS10_SWITCH_EN (1<<0)
|
|
|
|
#define REGULATOR_SLAVE 0
|
|
|
|
static int palmas_smps_read(struct palmas *palmas, unsigned int reg,
|
|
unsigned int *dest)
|
|
{
|
|
unsigned int addr;
|
|
|
|
addr = PALMAS_BASE_TO_REG(PALMAS_SMPS_BASE, reg);
|
|
|
|
return regmap_read(palmas->regmap[REGULATOR_SLAVE], addr, dest);
|
|
}
|
|
|
|
static int palmas_smps_write(struct palmas *palmas, unsigned int reg,
|
|
unsigned int value)
|
|
{
|
|
unsigned int addr;
|
|
|
|
addr = PALMAS_BASE_TO_REG(PALMAS_SMPS_BASE, reg);
|
|
|
|
return regmap_write(palmas->regmap[REGULATOR_SLAVE], addr, value);
|
|
}
|
|
|
|
static int palmas_ldo_read(struct palmas *palmas, unsigned int reg,
|
|
unsigned int *dest)
|
|
{
|
|
unsigned int addr;
|
|
|
|
addr = PALMAS_BASE_TO_REG(PALMAS_LDO_BASE, reg);
|
|
|
|
return regmap_read(palmas->regmap[REGULATOR_SLAVE], addr, dest);
|
|
}
|
|
|
|
static int palmas_ldo_write(struct palmas *palmas, unsigned int reg,
|
|
unsigned int value)
|
|
{
|
|
unsigned int addr;
|
|
|
|
addr = PALMAS_BASE_TO_REG(PALMAS_LDO_BASE, reg);
|
|
|
|
return regmap_write(palmas->regmap[REGULATOR_SLAVE], addr, value);
|
|
}
|
|
|
|
static int palmas_is_enabled_smps(struct regulator_dev *dev)
|
|
{
|
|
struct palmas_pmic *pmic = rdev_get_drvdata(dev);
|
|
int id = rdev_get_id(dev);
|
|
unsigned int reg;
|
|
|
|
palmas_smps_read(pmic->palmas, palmas_regs_info[id].ctrl_addr, ®);
|
|
|
|
reg &= PALMAS_SMPS12_CTRL_STATUS_MASK;
|
|
reg >>= PALMAS_SMPS12_CTRL_STATUS_SHIFT;
|
|
|
|
return !!(reg);
|
|
}
|
|
|
|
static int palmas_enable_smps(struct regulator_dev *dev)
|
|
{
|
|
struct palmas_pmic *pmic = rdev_get_drvdata(dev);
|
|
int id = rdev_get_id(dev);
|
|
unsigned int reg;
|
|
|
|
palmas_smps_read(pmic->palmas, palmas_regs_info[id].ctrl_addr, ®);
|
|
|
|
reg &= ~PALMAS_SMPS12_CTRL_MODE_ACTIVE_MASK;
|
|
if (pmic->current_reg_mode[id])
|
|
reg |= pmic->current_reg_mode[id];
|
|
else
|
|
reg |= SMPS_CTRL_MODE_ON;
|
|
|
|
palmas_smps_write(pmic->palmas, palmas_regs_info[id].ctrl_addr, reg);
|
|
|
|
return 0;
|
|
}
|
|
|
|
static int palmas_disable_smps(struct regulator_dev *dev)
|
|
{
|
|
struct palmas_pmic *pmic = rdev_get_drvdata(dev);
|
|
int id = rdev_get_id(dev);
|
|
unsigned int reg;
|
|
|
|
palmas_smps_read(pmic->palmas, palmas_regs_info[id].ctrl_addr, ®);
|
|
|
|
reg &= ~PALMAS_SMPS12_CTRL_MODE_ACTIVE_MASK;
|
|
|
|
palmas_smps_write(pmic->palmas, palmas_regs_info[id].ctrl_addr, reg);
|
|
|
|
return 0;
|
|
}
|
|
|
|
static int palmas_set_mode_smps(struct regulator_dev *dev, unsigned int mode)
|
|
{
|
|
struct palmas_pmic *pmic = rdev_get_drvdata(dev);
|
|
int id = rdev_get_id(dev);
|
|
unsigned int reg;
|
|
bool rail_enable = true;
|
|
|
|
palmas_smps_read(pmic->palmas, palmas_regs_info[id].ctrl_addr, ®);
|
|
reg &= ~PALMAS_SMPS12_CTRL_MODE_ACTIVE_MASK;
|
|
|
|
if (reg == SMPS_CTRL_MODE_OFF)
|
|
rail_enable = false;
|
|
|
|
switch (mode) {
|
|
case REGULATOR_MODE_NORMAL:
|
|
reg |= SMPS_CTRL_MODE_ON;
|
|
break;
|
|
case REGULATOR_MODE_IDLE:
|
|
reg |= SMPS_CTRL_MODE_ECO;
|
|
break;
|
|
case REGULATOR_MODE_FAST:
|
|
reg |= SMPS_CTRL_MODE_PWM;
|
|
break;
|
|
default:
|
|
return -EINVAL;
|
|
}
|
|
|
|
pmic->current_reg_mode[id] = reg & PALMAS_SMPS12_CTRL_MODE_ACTIVE_MASK;
|
|
if (rail_enable)
|
|
palmas_smps_write(pmic->palmas,
|
|
palmas_regs_info[id].ctrl_addr, reg);
|
|
return 0;
|
|
}
|
|
|
|
static unsigned int palmas_get_mode_smps(struct regulator_dev *dev)
|
|
{
|
|
struct palmas_pmic *pmic = rdev_get_drvdata(dev);
|
|
int id = rdev_get_id(dev);
|
|
unsigned int reg;
|
|
|
|
reg = pmic->current_reg_mode[id] & PALMAS_SMPS12_CTRL_MODE_ACTIVE_MASK;
|
|
|
|
switch (reg) {
|
|
case SMPS_CTRL_MODE_ON:
|
|
return REGULATOR_MODE_NORMAL;
|
|
case SMPS_CTRL_MODE_ECO:
|
|
return REGULATOR_MODE_IDLE;
|
|
case SMPS_CTRL_MODE_PWM:
|
|
return REGULATOR_MODE_FAST;
|
|
}
|
|
|
|
return 0;
|
|
}
|
|
|
|
static int palmas_list_voltage_smps(struct regulator_dev *dev,
|
|
unsigned selector)
|
|
{
|
|
struct palmas_pmic *pmic = rdev_get_drvdata(dev);
|
|
int id = rdev_get_id(dev);
|
|
int mult = 1;
|
|
|
|
/* Read the multiplier set in VSEL register to return
|
|
* the correct voltage.
|
|
*/
|
|
if (pmic->range[id])
|
|
mult = 2;
|
|
|
|
if (selector == 0)
|
|
return 0;
|
|
else if (selector < 6)
|
|
return 500000 * mult;
|
|
else
|
|
/* Voltage is linear mapping starting from selector 6,
|
|
* volt = (0.49V + ((selector - 5) * 0.01V)) * RANGE
|
|
* RANGE is either x1 or x2
|
|
*/
|
|
return (490000 + ((selector - 5) * 10000)) * mult;
|
|
}
|
|
|
|
static int palmas_map_voltage_smps(struct regulator_dev *rdev,
|
|
int min_uV, int max_uV)
|
|
{
|
|
struct palmas_pmic *pmic = rdev_get_drvdata(rdev);
|
|
int id = rdev_get_id(rdev);
|
|
int ret, voltage;
|
|
|
|
if (min_uV == 0)
|
|
return 0;
|
|
|
|
if (pmic->range[id]) { /* RANGE is x2 */
|
|
if (min_uV < 1000000)
|
|
min_uV = 1000000;
|
|
ret = DIV_ROUND_UP(min_uV - 1000000, 20000) + 6;
|
|
} else { /* RANGE is x1 */
|
|
if (min_uV < 500000)
|
|
min_uV = 500000;
|
|
ret = DIV_ROUND_UP(min_uV - 500000, 10000) + 6;
|
|
}
|
|
|
|
/* Map back into a voltage to verify we're still in bounds */
|
|
voltage = palmas_list_voltage_smps(rdev, ret);
|
|
if (voltage < min_uV || voltage > max_uV)
|
|
return -EINVAL;
|
|
|
|
return ret;
|
|
}
|
|
|
|
static int palma_smps_set_voltage_smps_time_sel(struct regulator_dev *rdev,
|
|
unsigned int old_selector, unsigned int new_selector)
|
|
{
|
|
struct palmas_pmic *pmic = rdev_get_drvdata(rdev);
|
|
int id = rdev_get_id(rdev);
|
|
int old_uv, new_uv;
|
|
unsigned int ramp_delay = pmic->ramp_delay[id];
|
|
|
|
if (!ramp_delay)
|
|
return 0;
|
|
|
|
old_uv = palmas_list_voltage_smps(rdev, old_selector);
|
|
if (old_uv < 0)
|
|
return old_uv;
|
|
|
|
new_uv = palmas_list_voltage_smps(rdev, new_selector);
|
|
if (new_uv < 0)
|
|
return new_uv;
|
|
|
|
return DIV_ROUND_UP(abs(old_uv - new_uv), ramp_delay);
|
|
}
|
|
|
|
static int palmas_smps_set_ramp_delay(struct regulator_dev *rdev,
|
|
int ramp_delay)
|
|
{
|
|
struct palmas_pmic *pmic = rdev_get_drvdata(rdev);
|
|
int id = rdev_get_id(rdev);
|
|
unsigned int reg = 0;
|
|
unsigned int addr = palmas_regs_info[id].tstep_addr;
|
|
int ret;
|
|
|
|
/* SMPS3 and SMPS7 do not have tstep_addr setting */
|
|
switch (id) {
|
|
case PALMAS_REG_SMPS3:
|
|
case PALMAS_REG_SMPS7:
|
|
return 0;
|
|
}
|
|
|
|
if (ramp_delay <= 0)
|
|
reg = 0;
|
|
else if (ramp_delay <= 2500)
|
|
reg = 3;
|
|
else if (ramp_delay <= 5000)
|
|
reg = 2;
|
|
else
|
|
reg = 1;
|
|
|
|
ret = palmas_smps_write(pmic->palmas, addr, reg);
|
|
if (ret < 0) {
|
|
dev_err(pmic->palmas->dev, "TSTEP write failed: %d\n", ret);
|
|
return ret;
|
|
}
|
|
|
|
pmic->ramp_delay[id] = palmas_smps_ramp_delay[reg];
|
|
return ret;
|
|
}
|
|
|
|
static struct regulator_ops palmas_ops_smps = {
|
|
.is_enabled = palmas_is_enabled_smps,
|
|
.enable = palmas_enable_smps,
|
|
.disable = palmas_disable_smps,
|
|
.set_mode = palmas_set_mode_smps,
|
|
.get_mode = palmas_get_mode_smps,
|
|
.get_voltage_sel = regulator_get_voltage_sel_regmap,
|
|
.set_voltage_sel = regulator_set_voltage_sel_regmap,
|
|
.list_voltage = palmas_list_voltage_smps,
|
|
.map_voltage = palmas_map_voltage_smps,
|
|
.set_voltage_time_sel = palma_smps_set_voltage_smps_time_sel,
|
|
.set_ramp_delay = palmas_smps_set_ramp_delay,
|
|
};
|
|
|
|
static struct regulator_ops palmas_ops_smps10 = {
|
|
.is_enabled = regulator_is_enabled_regmap,
|
|
.enable = regulator_enable_regmap,
|
|
.disable = regulator_disable_regmap,
|
|
.get_voltage_sel = regulator_get_voltage_sel_regmap,
|
|
.set_voltage_sel = regulator_set_voltage_sel_regmap,
|
|
.list_voltage = regulator_list_voltage_linear,
|
|
.map_voltage = regulator_map_voltage_linear,
|
|
};
|
|
|
|
static int palmas_is_enabled_ldo(struct regulator_dev *dev)
|
|
{
|
|
struct palmas_pmic *pmic = rdev_get_drvdata(dev);
|
|
int id = rdev_get_id(dev);
|
|
unsigned int reg;
|
|
|
|
palmas_ldo_read(pmic->palmas, palmas_regs_info[id].ctrl_addr, ®);
|
|
|
|
reg &= PALMAS_LDO1_CTRL_STATUS;
|
|
|
|
return !!(reg);
|
|
}
|
|
|
|
static struct regulator_ops palmas_ops_ldo = {
|
|
.is_enabled = palmas_is_enabled_ldo,
|
|
.enable = regulator_enable_regmap,
|
|
.disable = regulator_disable_regmap,
|
|
.get_voltage_sel = regulator_get_voltage_sel_regmap,
|
|
.set_voltage_sel = regulator_set_voltage_sel_regmap,
|
|
.list_voltage = regulator_list_voltage_linear,
|
|
.map_voltage = regulator_map_voltage_linear,
|
|
};
|
|
|
|
static struct regulator_ops palmas_ops_extreg = {
|
|
.is_enabled = regulator_is_enabled_regmap,
|
|
.enable = regulator_enable_regmap,
|
|
.disable = regulator_disable_regmap,
|
|
};
|
|
|
|
/*
|
|
* setup the hardware based sleep configuration of the SMPS/LDO regulators
|
|
* from the platform data. This is different to the software based control
|
|
* supported by the regulator framework as it is controlled by toggling
|
|
* pins on the PMIC such as PREQ, SYSEN, ...
|
|
*/
|
|
static int palmas_smps_init(struct palmas *palmas, int id,
|
|
struct palmas_reg_init *reg_init)
|
|
{
|
|
unsigned int reg;
|
|
unsigned int addr;
|
|
int ret;
|
|
|
|
addr = palmas_regs_info[id].ctrl_addr;
|
|
|
|
ret = palmas_smps_read(palmas, addr, ®);
|
|
if (ret)
|
|
return ret;
|
|
|
|
switch (id) {
|
|
case PALMAS_REG_SMPS10:
|
|
reg &= ~PALMAS_SMPS10_CTRL_MODE_SLEEP_MASK;
|
|
if (reg_init->mode_sleep)
|
|
reg |= reg_init->mode_sleep <<
|
|
PALMAS_SMPS10_CTRL_MODE_SLEEP_SHIFT;
|
|
break;
|
|
default:
|
|
if (reg_init->warm_reset)
|
|
reg |= PALMAS_SMPS12_CTRL_WR_S;
|
|
else
|
|
reg &= ~PALMAS_SMPS12_CTRL_WR_S;
|
|
|
|
if (reg_init->roof_floor)
|
|
reg |= PALMAS_SMPS12_CTRL_ROOF_FLOOR_EN;
|
|
else
|
|
reg &= ~PALMAS_SMPS12_CTRL_ROOF_FLOOR_EN;
|
|
|
|
reg &= ~PALMAS_SMPS12_CTRL_MODE_SLEEP_MASK;
|
|
if (reg_init->mode_sleep)
|
|
reg |= reg_init->mode_sleep <<
|
|
PALMAS_SMPS12_CTRL_MODE_SLEEP_SHIFT;
|
|
}
|
|
|
|
ret = palmas_smps_write(palmas, addr, reg);
|
|
if (ret)
|
|
return ret;
|
|
|
|
if (palmas_regs_info[id].vsel_addr && reg_init->vsel) {
|
|
addr = palmas_regs_info[id].vsel_addr;
|
|
|
|
reg = reg_init->vsel;
|
|
|
|
ret = palmas_smps_write(palmas, addr, reg);
|
|
if (ret)
|
|
return ret;
|
|
}
|
|
|
|
|
|
return 0;
|
|
}
|
|
|
|
static int palmas_ldo_init(struct palmas *palmas, int id,
|
|
struct palmas_reg_init *reg_init)
|
|
{
|
|
unsigned int reg;
|
|
unsigned int addr;
|
|
int ret;
|
|
|
|
addr = palmas_regs_info[id].ctrl_addr;
|
|
|
|
ret = palmas_ldo_read(palmas, addr, ®);
|
|
if (ret)
|
|
return ret;
|
|
|
|
if (reg_init->warm_reset)
|
|
reg |= PALMAS_LDO1_CTRL_WR_S;
|
|
else
|
|
reg &= ~PALMAS_LDO1_CTRL_WR_S;
|
|
|
|
if (reg_init->mode_sleep)
|
|
reg |= PALMAS_LDO1_CTRL_MODE_SLEEP;
|
|
else
|
|
reg &= ~PALMAS_LDO1_CTRL_MODE_SLEEP;
|
|
|
|
ret = palmas_ldo_write(palmas, addr, reg);
|
|
if (ret)
|
|
return ret;
|
|
|
|
return 0;
|
|
}
|
|
|
|
static int palmas_extreg_init(struct palmas *palmas, int id,
|
|
struct palmas_reg_init *reg_init)
|
|
{
|
|
unsigned int addr;
|
|
int ret;
|
|
unsigned int val = 0;
|
|
|
|
addr = palmas_regs_info[id].ctrl_addr;
|
|
|
|
if (reg_init->mode_sleep)
|
|
val = PALMAS_REGEN1_CTRL_MODE_SLEEP;
|
|
|
|
ret = palmas_update_bits(palmas, PALMAS_RESOURCE_BASE,
|
|
addr, PALMAS_REGEN1_CTRL_MODE_SLEEP, val);
|
|
if (ret < 0) {
|
|
dev_err(palmas->dev, "Resource reg 0x%02x update failed %d\n",
|
|
addr, ret);
|
|
return ret;
|
|
}
|
|
return 0;
|
|
}
|
|
|
|
static void palmas_enable_ldo8_track(struct palmas *palmas)
|
|
{
|
|
unsigned int reg;
|
|
unsigned int addr;
|
|
int ret;
|
|
|
|
addr = palmas_regs_info[PALMAS_REG_LDO8].ctrl_addr;
|
|
|
|
ret = palmas_ldo_read(palmas, addr, ®);
|
|
if (ret) {
|
|
dev_err(palmas->dev, "Error in reading ldo8 control reg\n");
|
|
return;
|
|
}
|
|
|
|
reg |= PALMAS_LDO8_CTRL_LDO_TRACKING_EN;
|
|
ret = palmas_ldo_write(palmas, addr, reg);
|
|
if (ret < 0) {
|
|
dev_err(palmas->dev, "Error in enabling tracking mode\n");
|
|
return;
|
|
}
|
|
/*
|
|
* When SMPS45 is set to off and LDO8 tracking is enabled, the LDO8
|
|
* output is defined by the LDO8_VOLTAGE.VSEL register divided by two,
|
|
* and can be set from 0.45 to 1.65 V.
|
|
*/
|
|
addr = palmas_regs_info[PALMAS_REG_LDO8].vsel_addr;
|
|
ret = palmas_ldo_read(palmas, addr, ®);
|
|
if (ret) {
|
|
dev_err(palmas->dev, "Error in reading ldo8 voltage reg\n");
|
|
return;
|
|
}
|
|
|
|
reg = (reg << 1) & PALMAS_LDO8_VOLTAGE_VSEL_MASK;
|
|
ret = palmas_ldo_write(palmas, addr, reg);
|
|
if (ret < 0)
|
|
dev_err(palmas->dev, "Error in setting ldo8 voltage reg\n");
|
|
|
|
return;
|
|
}
|
|
|
|
static struct of_regulator_match palmas_matches[] = {
|
|
{ .name = "smps12", },
|
|
{ .name = "smps123", },
|
|
{ .name = "smps3", },
|
|
{ .name = "smps45", },
|
|
{ .name = "smps457", },
|
|
{ .name = "smps6", },
|
|
{ .name = "smps7", },
|
|
{ .name = "smps8", },
|
|
{ .name = "smps9", },
|
|
{ .name = "smps10", },
|
|
{ .name = "ldo1", },
|
|
{ .name = "ldo2", },
|
|
{ .name = "ldo3", },
|
|
{ .name = "ldo4", },
|
|
{ .name = "ldo5", },
|
|
{ .name = "ldo6", },
|
|
{ .name = "ldo7", },
|
|
{ .name = "ldo8", },
|
|
{ .name = "ldo9", },
|
|
{ .name = "ldoln", },
|
|
{ .name = "ldousb", },
|
|
{ .name = "regen1", },
|
|
{ .name = "regen2", },
|
|
{ .name = "regen3", },
|
|
{ .name = "sysen1", },
|
|
{ .name = "sysen2", },
|
|
};
|
|
|
|
static void palmas_dt_to_pdata(struct device *dev,
|
|
struct device_node *node,
|
|
struct palmas_pmic_platform_data *pdata)
|
|
{
|
|
struct device_node *regulators;
|
|
u32 prop;
|
|
int idx, ret;
|
|
|
|
node = of_node_get(node);
|
|
regulators = of_find_node_by_name(node, "regulators");
|
|
if (!regulators) {
|
|
dev_info(dev, "regulator node not found\n");
|
|
return;
|
|
}
|
|
|
|
ret = of_regulator_match(dev, regulators, palmas_matches,
|
|
PALMAS_NUM_REGS);
|
|
of_node_put(regulators);
|
|
if (ret < 0) {
|
|
dev_err(dev, "Error parsing regulator init data: %d\n", ret);
|
|
return;
|
|
}
|
|
|
|
for (idx = 0; idx < PALMAS_NUM_REGS; idx++) {
|
|
if (!palmas_matches[idx].init_data ||
|
|
!palmas_matches[idx].of_node)
|
|
continue;
|
|
|
|
pdata->reg_data[idx] = palmas_matches[idx].init_data;
|
|
|
|
pdata->reg_init[idx] = devm_kzalloc(dev,
|
|
sizeof(struct palmas_reg_init), GFP_KERNEL);
|
|
|
|
pdata->reg_init[idx]->warm_reset =
|
|
of_property_read_bool(palmas_matches[idx].of_node,
|
|
"ti,warm-reset");
|
|
|
|
pdata->reg_init[idx]->roof_floor =
|
|
of_property_read_bool(palmas_matches[idx].of_node,
|
|
"ti,roof-floor");
|
|
|
|
ret = of_property_read_u32(palmas_matches[idx].of_node,
|
|
"ti,mode-sleep", &prop);
|
|
if (!ret)
|
|
pdata->reg_init[idx]->mode_sleep = prop;
|
|
|
|
ret = of_property_read_bool(palmas_matches[idx].of_node,
|
|
"ti,smps-range");
|
|
if (ret)
|
|
pdata->reg_init[idx]->vsel =
|
|
PALMAS_SMPS12_VOLTAGE_RANGE;
|
|
|
|
if (idx == PALMAS_REG_LDO8)
|
|
pdata->enable_ldo8_tracking = of_property_read_bool(
|
|
palmas_matches[idx].of_node,
|
|
"ti,enable-ldo8-tracking");
|
|
}
|
|
|
|
pdata->ldo6_vibrator = of_property_read_bool(node, "ti,ldo6-vibrator");
|
|
}
|
|
|
|
|
|
static int palmas_regulators_probe(struct platform_device *pdev)
|
|
{
|
|
struct palmas *palmas = dev_get_drvdata(pdev->dev.parent);
|
|
struct palmas_pmic_platform_data *pdata = pdev->dev.platform_data;
|
|
struct device_node *node = pdev->dev.of_node;
|
|
struct regulator_dev *rdev;
|
|
struct regulator_config config = { };
|
|
struct palmas_pmic *pmic;
|
|
struct palmas_reg_init *reg_init;
|
|
int id = 0, ret;
|
|
unsigned int addr, reg;
|
|
|
|
if (node && !pdata) {
|
|
pdata = devm_kzalloc(&pdev->dev, sizeof(*pdata), GFP_KERNEL);
|
|
|
|
if (!pdata)
|
|
return -ENOMEM;
|
|
|
|
palmas_dt_to_pdata(&pdev->dev, node, pdata);
|
|
}
|
|
|
|
pmic = devm_kzalloc(&pdev->dev, sizeof(*pmic), GFP_KERNEL);
|
|
if (!pmic)
|
|
return -ENOMEM;
|
|
|
|
pmic->dev = &pdev->dev;
|
|
pmic->palmas = palmas;
|
|
palmas->pmic = pmic;
|
|
platform_set_drvdata(pdev, pmic);
|
|
|
|
ret = palmas_smps_read(palmas, PALMAS_SMPS_CTRL, ®);
|
|
if (ret)
|
|
return ret;
|
|
|
|
if (reg & PALMAS_SMPS_CTRL_SMPS12_SMPS123_EN)
|
|
pmic->smps123 = 1;
|
|
|
|
if (reg & PALMAS_SMPS_CTRL_SMPS45_SMPS457_EN)
|
|
pmic->smps457 = 1;
|
|
|
|
config.regmap = palmas->regmap[REGULATOR_SLAVE];
|
|
config.dev = &pdev->dev;
|
|
config.driver_data = pmic;
|
|
|
|
for (id = 0; id < PALMAS_REG_LDO1; id++) {
|
|
bool ramp_delay_support = false;
|
|
|
|
/*
|
|
* Miss out regulators which are not available due
|
|
* to slaving configurations.
|
|
*/
|
|
switch (id) {
|
|
case PALMAS_REG_SMPS12:
|
|
case PALMAS_REG_SMPS3:
|
|
if (pmic->smps123)
|
|
continue;
|
|
if (id == PALMAS_REG_SMPS12)
|
|
ramp_delay_support = true;
|
|
break;
|
|
case PALMAS_REG_SMPS123:
|
|
if (!pmic->smps123)
|
|
continue;
|
|
ramp_delay_support = true;
|
|
break;
|
|
case PALMAS_REG_SMPS45:
|
|
case PALMAS_REG_SMPS7:
|
|
if (pmic->smps457)
|
|
continue;
|
|
if (id == PALMAS_REG_SMPS45)
|
|
ramp_delay_support = true;
|
|
break;
|
|
case PALMAS_REG_SMPS457:
|
|
if (!pmic->smps457)
|
|
continue;
|
|
ramp_delay_support = true;
|
|
break;
|
|
}
|
|
|
|
if ((id == PALMAS_REG_SMPS6) || (id == PALMAS_REG_SMPS8))
|
|
ramp_delay_support = true;
|
|
|
|
if (ramp_delay_support) {
|
|
addr = palmas_regs_info[id].tstep_addr;
|
|
ret = palmas_smps_read(pmic->palmas, addr, ®);
|
|
if (ret < 0) {
|
|
dev_err(&pdev->dev,
|
|
"reading TSTEP reg failed: %d\n", ret);
|
|
goto err_unregister_regulator;
|
|
}
|
|
pmic->desc[id].ramp_delay =
|
|
palmas_smps_ramp_delay[reg & 0x3];
|
|
pmic->ramp_delay[id] = pmic->desc[id].ramp_delay;
|
|
}
|
|
|
|
/* Initialise sleep/init values from platform data */
|
|
if (pdata && pdata->reg_init[id]) {
|
|
reg_init = pdata->reg_init[id];
|
|
ret = palmas_smps_init(palmas, id, reg_init);
|
|
if (ret)
|
|
goto err_unregister_regulator;
|
|
}
|
|
|
|
/* Register the regulators */
|
|
pmic->desc[id].name = palmas_regs_info[id].name;
|
|
pmic->desc[id].id = id;
|
|
|
|
switch (id) {
|
|
case PALMAS_REG_SMPS10:
|
|
pmic->desc[id].n_voltages = PALMAS_SMPS10_NUM_VOLTAGES;
|
|
pmic->desc[id].ops = &palmas_ops_smps10;
|
|
pmic->desc[id].vsel_reg =
|
|
PALMAS_BASE_TO_REG(PALMAS_SMPS_BASE,
|
|
PALMAS_SMPS10_CTRL);
|
|
pmic->desc[id].vsel_mask = SMPS10_VSEL;
|
|
pmic->desc[id].enable_reg =
|
|
PALMAS_BASE_TO_REG(PALMAS_SMPS_BASE,
|
|
PALMAS_SMPS10_CTRL);
|
|
pmic->desc[id].enable_mask = SMPS10_BOOST_EN;
|
|
pmic->desc[id].min_uV = 3750000;
|
|
pmic->desc[id].uV_step = 1250000;
|
|
break;
|
|
default:
|
|
/*
|
|
* Read and store the RANGE bit for later use
|
|
* This must be done before regulator is probed,
|
|
* otherwise we error in probe with unsupportable
|
|
* ranges. Read the current smps mode for later use.
|
|
*/
|
|
addr = palmas_regs_info[id].vsel_addr;
|
|
|
|
ret = palmas_smps_read(pmic->palmas, addr, ®);
|
|
if (ret)
|
|
goto err_unregister_regulator;
|
|
if (reg & PALMAS_SMPS12_VOLTAGE_RANGE)
|
|
pmic->range[id] = 1;
|
|
|
|
pmic->desc[id].ops = &palmas_ops_smps;
|
|
pmic->desc[id].n_voltages = PALMAS_SMPS_NUM_VOLTAGES;
|
|
pmic->desc[id].vsel_reg =
|
|
PALMAS_BASE_TO_REG(PALMAS_SMPS_BASE,
|
|
palmas_regs_info[id].vsel_addr);
|
|
pmic->desc[id].vsel_mask =
|
|
PALMAS_SMPS12_VOLTAGE_VSEL_MASK;
|
|
|
|
/* Read the smps mode for later use. */
|
|
addr = palmas_regs_info[id].ctrl_addr;
|
|
ret = palmas_smps_read(pmic->palmas, addr, ®);
|
|
if (ret)
|
|
goto err_unregister_regulator;
|
|
pmic->current_reg_mode[id] = reg &
|
|
PALMAS_SMPS12_CTRL_MODE_ACTIVE_MASK;
|
|
}
|
|
|
|
pmic->desc[id].type = REGULATOR_VOLTAGE;
|
|
pmic->desc[id].owner = THIS_MODULE;
|
|
|
|
if (pdata)
|
|
config.init_data = pdata->reg_data[id];
|
|
else
|
|
config.init_data = NULL;
|
|
|
|
pmic->desc[id].supply_name = palmas_regs_info[id].sname;
|
|
config.of_node = palmas_matches[id].of_node;
|
|
|
|
rdev = regulator_register(&pmic->desc[id], &config);
|
|
if (IS_ERR(rdev)) {
|
|
dev_err(&pdev->dev,
|
|
"failed to register %s regulator\n",
|
|
pdev->name);
|
|
ret = PTR_ERR(rdev);
|
|
goto err_unregister_regulator;
|
|
}
|
|
|
|
/* Save regulator for cleanup */
|
|
pmic->rdev[id] = rdev;
|
|
}
|
|
|
|
/* Start this loop from the id left from previous loop */
|
|
for (; id < PALMAS_NUM_REGS; id++) {
|
|
|
|
/* Miss out regulators which are not available due
|
|
* to alternate functions.
|
|
*/
|
|
|
|
/* Register the regulators */
|
|
pmic->desc[id].name = palmas_regs_info[id].name;
|
|
pmic->desc[id].id = id;
|
|
pmic->desc[id].type = REGULATOR_VOLTAGE;
|
|
pmic->desc[id].owner = THIS_MODULE;
|
|
|
|
if (id < PALMAS_REG_REGEN1) {
|
|
pmic->desc[id].n_voltages = PALMAS_LDO_NUM_VOLTAGES;
|
|
pmic->desc[id].ops = &palmas_ops_ldo;
|
|
pmic->desc[id].min_uV = 900000;
|
|
pmic->desc[id].uV_step = 50000;
|
|
pmic->desc[id].linear_min_sel = 1;
|
|
pmic->desc[id].vsel_reg =
|
|
PALMAS_BASE_TO_REG(PALMAS_LDO_BASE,
|
|
palmas_regs_info[id].vsel_addr);
|
|
pmic->desc[id].vsel_mask =
|
|
PALMAS_LDO1_VOLTAGE_VSEL_MASK;
|
|
pmic->desc[id].enable_reg =
|
|
PALMAS_BASE_TO_REG(PALMAS_LDO_BASE,
|
|
palmas_regs_info[id].ctrl_addr);
|
|
pmic->desc[id].enable_mask =
|
|
PALMAS_LDO1_CTRL_MODE_ACTIVE;
|
|
|
|
/* Check if LDO8 is in tracking mode or not */
|
|
if (pdata && (id == PALMAS_REG_LDO8) &&
|
|
pdata->enable_ldo8_tracking) {
|
|
palmas_enable_ldo8_track(palmas);
|
|
pmic->desc[id].min_uV = 450000;
|
|
pmic->desc[id].uV_step = 25000;
|
|
}
|
|
} else {
|
|
pmic->desc[id].n_voltages = 1;
|
|
pmic->desc[id].ops = &palmas_ops_extreg;
|
|
pmic->desc[id].enable_reg =
|
|
PALMAS_BASE_TO_REG(PALMAS_RESOURCE_BASE,
|
|
palmas_regs_info[id].ctrl_addr);
|
|
pmic->desc[id].enable_mask =
|
|
PALMAS_REGEN1_CTRL_MODE_ACTIVE;
|
|
}
|
|
|
|
if (pdata)
|
|
config.init_data = pdata->reg_data[id];
|
|
else
|
|
config.init_data = NULL;
|
|
|
|
pmic->desc[id].supply_name = palmas_regs_info[id].sname;
|
|
config.of_node = palmas_matches[id].of_node;
|
|
|
|
rdev = regulator_register(&pmic->desc[id], &config);
|
|
if (IS_ERR(rdev)) {
|
|
dev_err(&pdev->dev,
|
|
"failed to register %s regulator\n",
|
|
pdev->name);
|
|
ret = PTR_ERR(rdev);
|
|
goto err_unregister_regulator;
|
|
}
|
|
|
|
/* Save regulator for cleanup */
|
|
pmic->rdev[id] = rdev;
|
|
|
|
/* Initialise sleep/init values from platform data */
|
|
if (pdata) {
|
|
reg_init = pdata->reg_init[id];
|
|
if (reg_init) {
|
|
if (id < PALMAS_REG_REGEN1)
|
|
ret = palmas_ldo_init(palmas,
|
|
id, reg_init);
|
|
else
|
|
ret = palmas_extreg_init(palmas,
|
|
id, reg_init);
|
|
if (ret) {
|
|
regulator_unregister(pmic->rdev[id]);
|
|
goto err_unregister_regulator;
|
|
}
|
|
}
|
|
}
|
|
}
|
|
|
|
|
|
return 0;
|
|
|
|
err_unregister_regulator:
|
|
while (--id >= 0)
|
|
regulator_unregister(pmic->rdev[id]);
|
|
return ret;
|
|
}
|
|
|
|
static int palmas_regulators_remove(struct platform_device *pdev)
|
|
{
|
|
struct palmas_pmic *pmic = platform_get_drvdata(pdev);
|
|
int id;
|
|
|
|
for (id = 0; id < PALMAS_NUM_REGS; id++)
|
|
regulator_unregister(pmic->rdev[id]);
|
|
return 0;
|
|
}
|
|
|
|
static struct of_device_id of_palmas_match_tbl[] = {
|
|
{ .compatible = "ti,palmas-pmic", },
|
|
{ .compatible = "ti,twl6035-pmic", },
|
|
{ .compatible = "ti,twl6036-pmic", },
|
|
{ .compatible = "ti,twl6037-pmic", },
|
|
{ .compatible = "ti,tps65913-pmic", },
|
|
{ .compatible = "ti,tps65914-pmic", },
|
|
{ .compatible = "ti,tps80036-pmic", },
|
|
{ /* end */ }
|
|
};
|
|
|
|
static struct platform_driver palmas_driver = {
|
|
.driver = {
|
|
.name = "palmas-pmic",
|
|
.of_match_table = of_palmas_match_tbl,
|
|
.owner = THIS_MODULE,
|
|
},
|
|
.probe = palmas_regulators_probe,
|
|
.remove = palmas_regulators_remove,
|
|
};
|
|
|
|
static int __init palmas_init(void)
|
|
{
|
|
return platform_driver_register(&palmas_driver);
|
|
}
|
|
subsys_initcall(palmas_init);
|
|
|
|
static void __exit palmas_exit(void)
|
|
{
|
|
platform_driver_unregister(&palmas_driver);
|
|
}
|
|
module_exit(palmas_exit);
|
|
|
|
MODULE_AUTHOR("Graeme Gregory <gg@slimlogic.co.uk>");
|
|
MODULE_DESCRIPTION("Palmas voltage regulator driver");
|
|
MODULE_LICENSE("GPL");
|
|
MODULE_ALIAS("platform:palmas-pmic");
|
|
MODULE_DEVICE_TABLE(of, of_palmas_match_tbl);
|