In high connection count usage, the NIC's filter table may be filled with
sufficiently many ARFS filters that further insertions fail. As this
does not represent a correctness issue, do not log the resulting MCDI
errors. Add a debug-level message under the (by default disabled)
rx_status category instead; and take the opportunity to do a little extra
expiry work.
Since there are now multiple workitems able to call __efx_filter_rfs_expire
on a given channel, it is possible for them to race and thus pass quotas
which, combined, exceed rfs_filter_count. Thus, don't WARN_ON if we loop
all the way around the table with quota left over.
Signed-off-by: Edward Cree <ecree@solarflare.com>
Tested-by: David Ahern <dahern@digitalocean.com>
Signed-off-by: Jakub Kicinski <jakub.kicinski@netronome.com>