pmbus_clear_faults() attempts to clear faults on non-existing real pages.
As a result, the command error bit in the status register is set, and faults
are not really cleared.
All byte writes to non-zero pages are requests to clear the status register
on that page. Since non-zero pages are virtual and do not exist on the chip,
there is nothing to do, and such requests have to be ignored. This fixes
above problem.
Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
With virtual pages and to be able to handle more chips, it is necessary to
virtualise pmbus_write_byte().
Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
Add support for voltage, current, and temperature peak (historic maximum)
attributes.
Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
Add support for voltage and temperature peak (historic maximum) attributes.
Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
Add support for voltage and current peak (historic maximum) attributes.
Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
Most PMBus devices provide manufacturer specific commands to read low and/or
high peak values for some or all of its sensors.
To support providing those values as lowest/highest attributes to the user,
introduce virtual PMBus commands. Those commands reside outside the normal
command set and have to be implemented in device specific code, which map the
virtual commands to device specific commands.
Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
With virtual register page support, it is now possible that the status register
on virtual pages does not exist or is itself virtual. To take this into account
when creating alarm attributes, generate those attributes only if the status
register on the respective page is known to exist.
Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
Some PMBus chips have non-standard sensor registers. An easy way to
support such sensors is to introduce virtual pages and map the non-standard
registers into standard registers on an extra page.
For this to work, the code verifying if the configured number of pages exists
has to be removed. Since a wrong number of pages can only be configured in a
front-end driver, this should not have a practical impact since the resulting
errors should be found during development and testing.
Also, functions to read the chip status while checking if a command register
exists must be modified to no longer set the page register before reading the
status, since the physical page associated with the checked register may not
exist. This does not make a functional difference since the page was already set
when the attempt to read the register was made.
Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
Some PMBus devices use non-standard registers for some of the sensors and/or
limits. To support such devices, add code to support reading and writing of word
size registers in device specific code.
Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
Some hwmon sysfs attributes have a length of 20 bytes (plus terminating 0).
I2C_NAME_SIZE is defined as 20 and thus can not be used to define the length
of hwmon sysfs attributes. Replace it with PMBUS_NAME_SIZE, set to 24.
Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
Add ADP4000, NCP4200 and NCP4208 to the list of devices supported by the generic
PMBus driver, and add device IDs to enable explicit instantiation.
Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
Acked-by: Jean Delvare <khali@linux-fr.org>
In VID mode, output voltages are measured and reported as VID values, and
have to be converted to voltages using VID conversion tables or functions.
Support is added for VR11 only at this time.
This patch enables support for PMBus devices supporting VID VR11 based output
voltage selection such as NCP4200 and NCP4208.
Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
Since the number of PMBus drivers is getting large, move them into
directory drivers/hwmon/pmbus to improve readability and scalability.
Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>