Yuanjiang Yu
d3e67c94e8 power: supply: sc27xx: Fix capacity saving function
We found sometimes we can not get the saving capacity to initialize the
battery capacity, the reason is the user area registers are put on power
always-on region, so we need delay some time to wait until values are
updated successfully.

Moreover we also should clear the USER_AREA_CLEAR register after setting
the USER_AREA_SET register, otherwise we can not save the values in the
USER_AREA_SET register.

Signed-off-by: Yuanjiang Yu <yuanjiang.yu@unisoc.com>
Signed-off-by: Baolin Wang <baolin.wang@linaro.org>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
2019-01-23 21:26:56 +01:00
Baolin Wang
3a28f203c5 power: supply: sc27xx: Fix the incorrect formula when converting capacity to coulomb counter
We should multiply the calibrated current data (cur_1000ma_adc) when
converting current capacity (mAh) to coulomb counter, which can get
an accurate coulomb counter from the fuel gauge controller.

Signed-off-by: Baolin Wang <baolin.wang@linaro.org>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
2019-01-23 21:26:56 +01:00
Baolin Wang
0a4f97a171 power: supply: sc27xx: Add one property to read charge voltage
Add POWER_SUPPLY_PROP_CONSTANT_CHARGE_VOLTAGE property to get charge
voltage sampling by ADC controller, which is used to validate if the
charge voltage is in normal range or not in charger manager.

Signed-off-by: Baolin Wang <baolin.wang@linaro.org>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
2019-01-23 21:26:56 +01:00
Yuanjiang Yu
4a040e7c72 power: supply: sc27xx: Save last battery capacity
Our charger manager can optimize the battery capacity periodically, so
we can save last battery capacity into registers. Then next system
power-on, we can read the last saved battery capacity as the initial
battery capacity, which can make the battery capacity more accurate.

Signed-off-by: Yuanjiang Yu <yuanjiang.yu@unisoc.com>
Signed-off-by: Baolin Wang <baolin.wang@linaro.org>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
2018-12-06 22:24:39 +01:00
Yuanjiang Yu
e2fb615b69 power: supply: sc27xx: Add suspend/resume interfaces
Add fuel gauge platform suspend and resume interfaces. In suspend state,
we should enable the low voltage and coulomb counter threshold interrupts
to wake up system to calibrate the battery capacity in lower voltage stage.

Signed-off-by: Yuanjiang Yu <yuanjiang.yu@unisoc.com>
Signed-off-by: Baolin Wang <baolin.wang@linaro.org>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
2018-12-06 01:04:30 +01:00
Yuanjiang Yu
edcb1c0a3f power: supply: sc27xx: Add fuel gauge low voltage alarm
Add low voltage alarm support to make sure the battery capacity
more accurate in lower voltage stage.

Signed-off-by: Yuanjiang Yu <yuanjiang.yu@unisoc.com>
Signed-off-by: Baolin Wang <baolin.wang@linaro.org>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
2018-12-06 01:04:30 +01:00
Baolin Wang
65c9fab7bc power: supply: sc27xx: Add fuel gauge calibration
This patch adds support to read calibration values from the eFuse controller
to calibrate the ADC values corresponding to current and voltage, which can
make the current and voltage data more accurate.

Signed-off-by: Baolin Wang <baolin.wang@linaro.org>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
2018-12-06 00:54:22 +01:00
Baolin Wang
195ca17037 power: supply: Add Spreadtrum SC27XX fuel gauge unit driver
This patch adds the Spreadtrum SC27XX serial PMICs fuel gauge support,
which is used to calculate the battery capacity.

Original-by: Yuanjiang Yu <yuanjiang.yu@unisoc.com>
Signed-off-by: Baolin Wang <baolin.wang@linaro.org>
Acked-by: Linus Walleij <linus.walleij@linaro.org>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
2018-11-09 22:55:46 +01:00