Commit Graph

11 Commits

Author SHA1 Message Date
Thomas Gleixner
a636cd6c42 treewide: Replace GPLv2 boilerplate/reference with SPDX - rule 4
Based on 1 normalized pattern(s):

  licensed under gplv2 or later

extracted by the scancode license scanner the SPDX license identifier

  GPL-2.0-or-later

has been chosen to replace the boilerplate/reference in 118 file(s).

Signed-off-by: Thomas Gleixner <tglx@linutronix.de>
Reviewed-by: Jilayne Lovejoy <opensource@jilayne.com>
Reviewed-by: Steve Winslow <swinslow@gmail.com>
Reviewed-by: Allison Randal <allison@lohutok.net>
Reviewed-by: Kate Stewart <kstewart@linuxfoundation.org>
Cc: linux-spdx@vger.kernel.org
Link: https://lkml.kernel.org/r/20190519154040.961286471@linutronix.de
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
2019-05-21 11:28:40 +02:00
Daniel Lezcano
1727339590 clocksource/drivers: Rename CLOCKSOURCE_OF_DECLARE to TIMER_OF_DECLARE
The CLOCKSOURCE_OF_DECLARE macro is used widely for the timers to declare the
clocksource at early stage. However, this macro is also used to initialize
the clockevent if any, or the clockevent only.

It was originally suggested to declare another macro to initialize a
clockevent, so in order to separate the two entities even they belong to the
same IP. This was not accepted because of the impact on the DT where splitting
a clocksource/clockevent definition does not make sense as it is a Linux
concept not a hardware description.

On the other side, the clocksource has not interrupt declared while the
clockevent has, so it is easy from the driver to know if the description is
for a clockevent or a clocksource, IOW it could be implemented at the driver
level.

So instead of dealing with a named clocksource macro, let's use a more generic
one: TIMER_OF_DECLARE.

The patch has not functional changes.

Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
Acked-by: Heiko Stuebner <heiko@sntech.de>
Acked-by: Neil Armstrong <narmstrong@baylibre.com>
Acked-by: Arnd Bergmann <arnd@arndb.de>
Acked-by: Matthias Brugger <matthias.bgg@gmail.com>
Reviewed-by: Linus Walleij <linus.walleij@linaro.org>
2017-06-14 11:58:45 +02:00
Nicolai Stange
547733c58d clockevents/drivers/atlas7: Set ->min_delta_ticks and ->max_delta_ticks
In preparation for making the clockevents core NTP correction aware,
all clockevent device drivers must set ->min_delta_ticks and
->max_delta_ticks rather than ->min_delta_ns and ->max_delta_ns: a
clockevent device's rate is going to change dynamically and thus, the
ratio of ns to ticks ceases to stay invariant.

Make the timer-atlas7 clockevent driver initialize these fields properly.

This patch alone doesn't introduce any change in functionality as the
clockevents core still looks exclusively at the (untouched) ->min_delta_ns
and ->max_delta_ns. As soon as this has changed, a followup patch will
purge the initialization of ->min_delta_ns and ->max_delta_ns from this
driver.

Cc: Ingo Molnar <mingo@redhat.com>
Cc: Thomas Gleixner <tglx@linutronix.de>
Cc: Daniel Lezcano <daniel.lezcano@linaro.org>
Cc: Richard Cochran <richardcochran@gmail.com>
Cc: Prarit Bhargava <prarit@redhat.com>
Cc: Stephen Boyd <sboyd@codeaurora.org>
Cc: Barry Song <baohua@kernel.org>
Cc: linux-arm-kernel@lists.infradead.org
Acked-by: Daniel Lezcano <daniel.lezcano@linaro.org>
Signed-off-by: Nicolai Stange <nicstange@gmail.com>
Signed-off-by: John Stultz <john.stultz@linaro.org>
2017-04-14 13:11:15 -07:00
Linus Torvalds
3ddc76dfc7 Merge branch 'timers-urgent-for-linus' of git://git.kernel.org/pub/scm/linux/kernel/git/tip/tip
Pull timer type cleanups from Thomas Gleixner:
 "This series does a tree wide cleanup of types related to
  timers/timekeeping.

   - Get rid of cycles_t and use a plain u64. The type is not really
     helpful and caused more confusion than clarity

   - Get rid of the ktime union. The union has become useless as we use
     the scalar nanoseconds storage unconditionally now. The 32bit
     timespec alike storage got removed due to the Y2038 limitations
     some time ago.

     That leaves the odd union access around for no reason. Clean it up.

  Both changes have been done with coccinelle and a small amount of
  manual mopping up"

* 'timers-urgent-for-linus' of git://git.kernel.org/pub/scm/linux/kernel/git/tip/tip:
  ktime: Get rid of ktime_equal()
  ktime: Cleanup ktime_set() usage
  ktime: Get rid of the union
  clocksource: Use a plain u64 instead of cycle_t
2016-12-25 14:30:04 -08:00
Thomas Gleixner
a5a1d1c291 clocksource: Use a plain u64 instead of cycle_t
There is no point in having an extra type for extra confusion. u64 is
unambiguous.

Conversion was done with the following coccinelle script:

@rem@
@@
-typedef u64 cycle_t;

@fix@
typedef cycle_t;
@@
-cycle_t
+u64

Signed-off-by: Thomas Gleixner <tglx@linutronix.de>
Cc: Peter Zijlstra <peterz@infradead.org>
Cc: John Stultz <john.stultz@linaro.org>
2016-12-25 11:04:12 +01:00
Thomas Gleixner
73c1b41e63 cpu/hotplug: Cleanup state names
When the state names got added a script was used to add the extra argument
to the calls. The script basically converted the state constant to a
string, but the cleanup to convert these strings into meaningful ones did
not happen.

Replace all the useless strings with 'subsys/xxx/yyy:state' strings which
are used in all the other places already.

Signed-off-by: Thomas Gleixner <tglx@linutronix.de>
Cc: Peter Zijlstra <peterz@infradead.org>
Cc: Sebastian Siewior <bigeasy@linutronix.de>
Link: http://lkml.kernel.org/r/20161221192112.085444152@linutronix.de
Signed-off-by: Thomas Gleixner <tglx@linutronix.de>
2016-12-25 10:47:44 +01:00
Richard Cochran
eb0a9d8c67 clocksource/atlas7: Convert to hotplug state machine
Install the callbacks via the state machine and let the core invoke
the callbacks on the already online CPUs.

Signed-off-by: Richard Cochran <rcochran@linutronix.de>
Signed-off-by: Anna-Maria Gleixner <anna-maria@linutronix.de>
Reviewed-by: Sebastian Andrzej Siewior <bigeasy@linutronix.de>
Cc: Barry Song <baohua@kernel.org>
Cc: Daniel Lezcano <daniel.lezcano@linaro.org>
Cc: Linus Torvalds <torvalds@linux-foundation.org>
Cc: Peter Zijlstra <peterz@infradead.org>
Cc: Thomas Gleixner <tglx@linutronix.de>
Cc: rt@linutronix.de
Link: http://lkml.kernel.org/r/20160713153338.310333816@linutronix.de
Signed-off-by: Ingo Molnar <mingo@kernel.org>
2016-07-15 10:41:45 +02:00
Daniel Lezcano
177cf6e52b clocksources: Switch back to the clksrc table
All the clocksource drivers's init function are now converted to return
an error code. CLOCKSOURCE_OF_DECLARE is no longer used as well as the
clksrc-of table.

Let's convert back the names:
 - CLOCKSOURCE_OF_DECLARE_RET => CLOCKSOURCE_OF_DECLARE
 - clksrc-of-ret              => clksrc-of

Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>

For exynos_mct and samsung_pwm_timer:
Acked-by: Krzysztof Kozlowski <k.kozlowski@samsung.com>

For arch/arc:
Acked-by: Vineet Gupta <vgupta@synopsys.com>

For mediatek driver:
Acked-by: Matthias Brugger <matthias.bgg@gmail.com>

For the Rockchip-part
Acked-by: Heiko Stuebner <heiko@sntech.de>

For STi :
Acked-by: Patrice Chotard <patrice.chotard@st.com>

For the mps2-timer.c and versatile.c changes:
Acked-by: Liviu Dudau <Liviu.Dudau@arm.com>

For the OXNAS part :
Acked-by: Neil Armstrong <narmstrong@baylibre.com>

For LPC32xx driver:
Acked-by: Sylvain Lemieux <slemieux.tyco@gmail.com>

For Broadcom Kona timer change:
Acked-by: Ray Jui <ray.jui@broadcom.com>

For Sun4i and Sun5i:
Acked-by: Chen-Yu Tsai <wens@csie.org>

For Meson6:
Acked-by: Carlo Caione <carlo@caione.org>

For Keystone:
Acked-by: Santosh Shilimkar <ssantosh@kernel.org>

For NPS:
Acked-by: Noam Camus <noamca@mellanox.com>

For bcm2835:
Acked-by: Eric Anholt <eric@anholt.net>
2016-06-28 10:19:35 +02:00
Daniel Lezcano
c41c96ddac clocksource/drivers/atlas7: Convert init function to return error
The init functions do not return any error. They behave as the following:

  - panic, thus leading to a kernel crash while another timer may work and
       make the system boot up correctly

  or

  - print an error and let the caller unaware if the state of the system

Change that by converting the init functions to return an error conforming
to the CLOCKSOURCE_OF_RET prototype.

Proper error handling (rollback, errno value) will be changed later case
by case, thus this change just return back an error or success in the init
function.

Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
2016-06-28 10:19:28 +02:00
Viresh Kumar
1e729d378e clockevents/drivers/atlas7: Migrate to new 'set-state' interface
Migrate atlas7 driver to the new 'set-state' interface provided by
clockevents core, the earlier 'set-mode' interface is marked obsolete
now.

This also enables us to implement callbacks for new states of clockevent
devices, for example: ONESHOT_STOPPED.

Cc: Barry Song <baohua@kernel.org>
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
2015-08-10 11:40:43 +02:00
Barry Song
5833ac9865 clocksource: marco: Rename marco to atlas7
marco project is replaced by atlas7 and we should obliterate
its all traces.

Signed-off-by: Barry Song <Baohua.Song@csr.com>
Acked-by: Arnd Bergmann <arnd@arndb.de>
Acked-by: Daniel Lezcano <daniel.lezcano@linaro.org>
Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
2015-01-29 14:02:06 +01:00