Upcoming change to DT compiler is going to complain about nodes
which have a reg property, but have not defined the address in their
name. This patch fixes following type of warnings for DM81x clock nodes:
Warning (unit_address_vs_reg): Node /ocp/cm@48004000/clocks/dpll3_m2_ck
has a reg or ranges property, but no unit name
Signed-off-by: Tero Kristo <t-kristo@ti.com>
Signed-off-by: Tony Lindgren <tony@atomide.com>
The clocks on dm816x are a bit different from the other omap
variants. The clocks are sourced from a FAPLL (Flying Adder PLL)
unlike on other omaps. Other than that, it's a similar setup
to am33xx with extra muxes and dividers that can be defined
as existing component clocks.
Cc: Brian Hutchinson <b.hutchman@gmail.com>
Cc: Paul Walmsley <paul@pwsan.com>
Cc: Tero Kristo <t-kristo@ti.com>
Signed-off-by: Tony Lindgren <tony@atomide.com>