The .remove code is broken in several ways.
- mdiobus_unregister() is called twice for the same object in case of dual FEC
- phy_disconnect() is being called when the PHY is already disconnected
- the requested IRQ(s) are not freed
- fec_stop() is being called with the inteface already stopped
All of those lead to kernel crashes if the remove function is actually used.
Signed-off-by: Lothar Waßmann <LW@KARO-electronics.de>
Tested-by: Shawn Guo <shawn.guo@linaro.org>
Acked-by: Shawn Guo <shawn.guo@linaro.org>
Signed-off-by: David S. Miller <davem@davemloft.net>
Additionally to setting the ETHER_EN bit in FEC_ECNTRL the MII/RMII
setting in FEC_R_CNTRL needs to be preserved to keep the MII interface
functional.
Signed-off-by: Lothar Waßmann <LW@KARO-electronics.de>
Tested-by: Shawn Guo <shawn.guo@linaro.org>
Acked-by: Shawn Guo <shawn.guo@linaro.org>
Signed-off-by: David S. Miller <davem@davemloft.net>
When the MAC address is supplied via platform_data it should be OK as
it is and should not be modified in case of a dual FEC setup.
Also copying the MAC from platform_data to the single 'macaddr'
variable will overwrite the MAC for the first interface in case of a
dual FEC setup.
Signed-off-by: Lothar Waßmann <LW@KARO-electronics.de>
Acked-by: Shawn Guo <shawn.guo@linaro.org>
Signed-off-by: David S. Miller <davem@davemloft.net>
prevent calling request_irq() with a known invalid IRQ number and
preserve the return value of the platform_get_irq() function
Signed-off-by: Lothar Waßmann <LW@KARO-electronics.de>
Acked-by: Shawn Guo <shawn.guo@linaro.org>
Signed-off-by: David S. Miller <davem@davemloft.net>
Upon detection of a FDX/HDX change the interface is restarted twice.
Signed-off-by: Lothar Waßmann <LW@KARO-electronics.de>
Acked-by: Shawn Guo <shawn.guo@linaro.org>
Signed-off-by: David S. Miller <davem@davemloft.net>
The con_id is actually not needed for clk_get().
Signed-off-by: Lothar Waßmann <LW@KARO-electronics.de>
Acked-by: Shawn Guo <shawn.guo@linaro.org>
Signed-off-by: David S. Miller <davem@davemloft.net>
- remove some bogus whitespace
- remove line wraps from printk messages
Signed-off-by: Lothar Waßmann <LW@KARO-electronics.de>
Acked-by: Shawn Guo <shawn.guo@linaro.org>
Signed-off-by: David S. Miller <davem@davemloft.net>
The pdev->id is used in several places for different purpose. All
these uses assume it's always the id of fec device which is >= 0.
However this is only true for non-DT case. When DT plays, pdev->id
is always -1, which will break these pdev->id users.
Instead of fixing all these users one by one, this patch introduces
a new member 'dev_id' to 'struct fec_enet_private' for holding the
correct fec device id, and replaces all the existing uses of pdev->id
with this dev_id.
Signed-off-by: Shawn Guo <shawn.guo@linaro.org>
Signed-off-by: David S. Miller <davem@davemloft.net>
Don't use hardcoded irq num and replace it with
FEC_IRQ_NUM macro.
Signed-off-by: Xiao Jiang <jgq516@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
The imx6q enet is a derivative of imx28 enet controller. It fixed
the frame endian issue found on imx28, and added 1 Gbps support.
It also fixes a typo on vendor name in Kconfig.
Signed-off-by: Shawn Guo <shawn.guo@linaro.org>
Signed-off-by: David S. Miller <davem@davemloft.net>
In function fec_enet_mii_init(), it uses non-zero pdev->id as part
of the condition to check the second fec instance (fec1). This works
before the driver supports device tree probe. But in case of device
tree probe, pdev->id is -1 which is also non-zero, so the logic becomes
broken when device tree probe gets supported.
The patch change the logic to check "pdev->id > 0" as the part of the
condition for identifying fec1.
Signed-off-by: Shawn Guo <shawn.guo@linaro.org>
Signed-off-by: David S. Miller <davem@davemloft.net>
FEC can work without a phy reset on some platforms, which means not
very platform necessarily have a phy-reset gpio encoded in device tree.
Even on the platforms that have the gpio, FEC can work without
resetting phy for some cases, e.g. boot loader has done that.
So it makes more sense to have the phy-reset-gpio request failure as
a debug message rather than a warning, and get fec_reset_phy() return
void since the caller does not check the return anyway.
Signed-off-by: Shawn Guo <shawn.guo@linaro.org>
Signed-off-by: David S. Miller <davem@davemloft.net>
Move the Freescale drivers into drivers/net/ethernet/freescale/ and
make the necessary Kconfig and Makefile changes.
CC: Sandeep Gopalpet <sandeep.kumar@freescale.com>
CC: Andy Fleming <afleming@freescale.com>
CC: Shlomi Gridish <gridish@freescale.com>
CC: Li Yang <leoli@freescale.com>
CC: Pantelis Antoniou <pantelis.antoniou@gmail.com>
CC: Vitaly Bordug <vbordug@ru.mvista.com>
CC: Dan Malek <dmalek@jlc.net>
CC: Sylvain Munaut <tnt@246tNt.com>
Signed-off-by: Jeff Kirsher <jeffrey.t.kirsher@intel.com>