send_login() does not check for the result of ibmvnic_send_crq() of the
login request. This results in the driver needlessly retrying the login
10 times even when CRQ is no longer active. Check the return code and
give up in case of errors in sending the CRQ.
The only time we want to retry is if we get a PARITALSUCCESS response
from the partner.
Fixes: 032c5e8284 ("Driver for IBM System i/p VNIC protocol")
Signed-off-by: Dany Madden <drt@linux.ibm.com>
Signed-off-by: Sukadev Bhattiprolu <sukadev@linux.ibm.com>
Signed-off-by: Jakub Kicinski <kuba@kernel.org>
If after ibmvnic sends a LOGIN it gets a FAILOVER, it is possible that
the worker thread will start reset process and free the login response
buffer before it gets a (now stale) LOGIN_RSP. The ibmvnic tasklet will
then try to access the login response buffer and crash.
Have ibmvnic track pending logins and discard any stale login responses.
Fixes: 032c5e8284 ("Driver for IBM System i/p VNIC protocol")
Signed-off-by: Sukadev Bhattiprolu <sukadev@linux.ibm.com>
Signed-off-by: Jakub Kicinski <kuba@kernel.org>
If auto-priority failover is enabled, the backing device needs time
to settle if hard resetting fails for any reason. Add a delay of 60
seconds before retrying the hard-reset.
Fixes: 2770a7984d ("ibmvnic: Introduce hard reset recovery")
Signed-off-by: Sukadev Bhattiprolu <sukadev@linux.ibm.com>
Signed-off-by: Jakub Kicinski <kuba@kernel.org>
In a failed reset, driver could end up in VNIC_PROBED or VNIC_CLOSED
state and cannot recover in subsequent resets, leaving it offline.
This patch restores the adapter state to reset_state, the original
state when reset was called.
Fixes: b27507bb59 ("net/ibmvnic: unlock rtnl_lock in reset so linkwatch_event can run")
Fixes: 2770a7984d ("ibmvnic: Introduce hard reset recovery")
Signed-off-by: Dany Madden <drt@linux.ibm.com>
Signed-off-by: Jakub Kicinski <kuba@kernel.org>
scrq->msgs could be NULL during device reset, causing Linux to crash.
So, check before memset scrq->msgs.
Fixes: c8b2ad0a4a ("ibmvnic: Sanitize entire SCRQ buffer on reset")
Signed-off-by: Dany Madden <drt@linux.ibm.com>
Signed-off-by: Lijun Pan <ljp@linux.ibm.com>
Signed-off-by: Jakub Kicinski <kuba@kernel.org>
When ibmvnic fails to reset, it breaks out of the reset loop and frees
all of the remaining resets from the workqueue. Doing so prevents the
adapter from recovering if no reset is scheduled after that. Instead,
have the driver continue to process resets on the workqueue.
Remove the no longer need free_all_rwi().
Fixes: ed651a1087 ("ibmvnic: Updated reset handling")
Signed-off-by: Dany Madden <drt@linux.ibm.com>
Signed-off-by: Jakub Kicinski <kuba@kernel.org>
Inconsistent login with the vnicserver is causing the device to be
removed. This does not give the device a chance to recover from error
state. This patch schedules a FATAL reset instead to bring the adapter
up.
Fixes: 032c5e8284 ("Driver for IBM System i/p VNIC protocol")
Signed-off-by: Dany Madden <drt@linux.ibm.com>
Signed-off-by: Lijun Pan <ljp@linux.ibm.com>
Signed-off-by: Jakub Kicinski <kuba@kernel.org>
Based on the discussion with Sukadev Bhattiprolu and Dany Madden,
we believe that checking adapter->resetting bit is preferred
since RESETTING state flag is not as strict as resetting bit.
RESETTING state flag is removed since it is verbose now.
Fixes: 7d7195a026 ("ibmvnic: Do not process device remove during device reset")
Signed-off-by: Lijun Pan <ljp@linux.ibm.com>
Signed-off-by: Jakub Kicinski <kuba@kernel.org>
Sometimes it takes longer than 5 seconds (watchdog timeout) to complete
failover, migration, and other resets. In stead of scheduling another
timeout reset, we wait for the current one to complete.
Suggested-by: Brian King <brking@linux.vnet.ibm.com>
Signed-off-by: Lijun Pan <ljp@linux.ibm.com>
Reviewed-by: Dany Madden <drt@linux.ibm.com>
Signed-off-by: Jakub Kicinski <kuba@kernel.org>
Commit 61d3e1d9bc ("ibmvnic: Remove netdev notify for failover resets")
excluded the failover case for notify call because it said
netdev_notify_peers() can cause network traffic to stall or halt.
Current testing does not show network traffic stall
or halt because of the notify call for failover event.
netdev_notify_peers may be used when a device wants to inform the
rest of the network about some sort of a reconfiguration
such as failover or migration.
It is unnecessary to call that in other events like
FATAL, NON_FATAL, CHANGE_PARAM, and TIMEOUT resets
since in those scenarios the hardware does not change.
If the driver must do a hard reset, it is necessary to notify peers.
Fixes: 61d3e1d9bc ("ibmvnic: Remove netdev notify for failover resets")
Suggested-by: Brian King <brking@linux.vnet.ibm.com>
Suggested-by: Pradeep Satyanarayana <pradeeps@linux.vnet.ibm.com>
Signed-off-by: Dany Madden <drt@linux.ibm.com>
Signed-off-by: Lijun Pan <ljp@linux.ibm.com>
Signed-off-by: Jakub Kicinski <kuba@kernel.org>
When netdev_notify_peers was substituted in
commit 986103e792 ("net/ibmvnic: Fix RTNL deadlock during device reset"),
call_netdevice_notifiers(NETDEV_RESEND_IGMP, dev) was missed.
Fix it now.
Fixes: 986103e792 ("net/ibmvnic: Fix RTNL deadlock during device reset")
Signed-off-by: Lijun Pan <ljp@linux.ibm.com>
Reviewed-by: Dany Madden <drt@linux.ibm.com>
Signed-off-by: Jakub Kicinski <kuba@kernel.org>
Commit 5a18e1e0c1 introduced the 'failover_pending' state to track
the "failover pending window" - where we wait for the partner to become
ready (after a transport event) before actually attempting to failover.
i.e window is between following two events:
a. we get a transport event due to a FAILOVER
b. later, we get CRQ_INITIALIZED indicating the partner is
ready at which point we schedule a FAILOVER reset.
and ->failover_pending is true during this window.
If during this window, we attempt to open (or close) a device, we pretend
that the operation succeded and let the FAILOVER reset path complete the
operation.
This is fine, except if the transport event ("a" above) occurs during the
open and after open has already checked whether a failover is pending. If
that happens, we fail the open, which can cause the boot scripts to leave
the interface down requiring administrator to manually bring up the device.
This fix "extends" the failover pending window till we are _actually_
ready to perform the failover reset (i.e until after we get the RTNL
lock). Since open() holds the RTNL lock, we can be sure that we either
finish the open or if the open() fails due to the failover pending window,
we can again pretend that open is done and let the failover complete it.
We could try and block the open until failover is completed but a) that
could still timeout the application and b) Existing code "pretends" that
failover occurred "just after" open succeeded, so marks the open successful
and lets the failover complete the open. So, mark the open successful even
if the transport event occurs before we actually start the open.
Fixes: 5a18e1e0c1 ("ibmvnic: Fix failover case for non-redundant configuration")
Signed-off-by: Sukadev Bhattiprolu <sukadev@linux.ibm.com>
Acked-by: Dany Madden <drt@linux.ibm.com>
Link: https://lore.kernel.org/r/20201030170711.1562994-1-sukadev@linux.ibm.com
Signed-off-by: Jakub Kicinski <kuba@kernel.org>
Jakub Kicinski brought up a concern in ibmvnic_set_mac().
ibmvnic_set_mac() does this:
ether_addr_copy(adapter->mac_addr, addr->sa_data);
if (adapter->state != VNIC_PROBED)
rc = __ibmvnic_set_mac(netdev, addr->sa_data);
So if state == VNIC_PROBED, the user can assign an invalid address to
adapter->mac_addr, and ibmvnic_set_mac() will still return 0.
The fix is to validate ethernet address at the beginning of
ibmvnic_set_mac(), and move the ether_addr_copy to
the case of "adapter->state != VNIC_PROBED".
Fixes: c26eba03e4 ("ibmvnic: Update reset infrastructure to support tunable parameters")
Signed-off-by: Lijun Pan <ljp@linux.ibm.com>
Link: https://lore.kernel.org/r/20201027220456.71450-1-ljp@linux.ibm.com
Signed-off-by: Jakub Kicinski <kuba@kernel.org>
After mac address change request completes successfully, the new mac
address need to be saved to adapter->mac_addr as well as
netdev->dev_addr. Otherwise, adapter->mac_addr still holds old
data.
Fixes: 62740e9788 ("net/ibmvnic: Update MAC address settings after adapter reset")
Signed-off-by: Lijun Pan <ljp@linux.ibm.com>
Link: https://lore.kernel.org/r/20201020223919.46106-1-ljp@linux.ibm.com
Signed-off-by: Jakub Kicinski <kuba@kernel.org>
Factor send_control_ip_offload out of handle_query_ip_offload_rsp.
Signed-off-by: Lijun Pan <ljp@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Factor send_query_ip_offload out of handle_request_cap_rsp to
pair with handle_query_ip_offload_rsp.
Signed-off-by: Lijun Pan <ljp@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
The new name send_query_map pairs with handle_query_map_rsp.
Signed-off-by: Lijun Pan <ljp@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
The new name send_request_cap pairs with handle_request_cap_rsp.
Signed-off-by: Lijun Pan <ljp@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
The new name send_query_cap pairs with handle_query_cap_rsp.
Signed-off-by: Lijun Pan <ljp@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Set up the speed according to crq->query_phys_parms.rsp.speed.
Fix IBMVNIC_10GBPS typo.
Fixes: f8d6ae0d27 ("ibmvnic: Report actual backing device speed and duplex values")
Signed-off-by: Lijun Pan <ljp@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Two minor conflicts:
1) net/ipv4/route.c, adding a new local variable while
moving another local variable and removing it's
initial assignment.
2) drivers/net/dsa/microchip/ksz9477.c, overlapping changes.
One pretty prints the port mode differently, whilst another
changes the driver to try and obtain the port mode from
the port node rather than the switch node.
Signed-off-by: David S. Miller <davem@davemloft.net>
This reverts commit 550f4d46af.
adapter->from_passive_init may be changed in ibmvnic_handle_crq
while ibmvnic_reset_init is waiting for the completion of
adapter->init_done.
Signed-off-by: Lijun Pan <ljp@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
In preparation for unconditionally passing the
struct tasklet_struct pointer to all tasklet
callbacks, switch to using the new tasklet_setup()
and from_tasklet() to pass the tasklet pointer explicitly.
Signed-off-by: Romain Perier <romain.perier@gmail.com>
Signed-off-by: Allen Pais <apais@linux.microsoft.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Indentation and logic clearly show that this code is missing
parenthesis.
Fixes: 9f13457377 ("ibmvnic fix NULL tx_pools and rx_tools issue at do_reset")
Signed-off-by: Jakub Kicinski <kuba@kernel.org>
We got slightly different patches removing a double word
in a comment in net/ipv4/raw.c - picked the version from net.
Simple conflict in drivers/net/ethernet/ibm/ibmvnic.c. Use cached
values instead of VNIC login response buffer (following what
commit 507ebe6444 ("ibmvnic: Fix use-after-free of VNIC login
response buffer") did).
Signed-off-by: Jakub Kicinski <kuba@kernel.org>
In some cases, the device or firmware may be busy when the
driver attempts to perform the CRQ initialization handshake.
If the partner is busy, the hypervisor will return the H_CLOSED
return code. The aim of this patch is that, if the device is not
ready, to query the device a number of times, with a small wait
time in between queries. If all initialization requests fail,
the driver will remain in a dormant state, awaiting a signal
from the device that it is ready for operation.
Signed-off-by: Thomas Falcon <tlfalcon@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
These two functions share the majority of the code, hence merge
them together. In the meanwhile, add a reset pass-in parameter
to differentiate them. Thus, the code is easier to read and to tell
the difference between reset_init and regular init.
Signed-off-by: Lijun Pan <ljp@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
At the beginning of the function, from_passive_init is set false by
"adapter->from_passive_init = false;",
hence the if statement will never run.
Signed-off-by: Lijun Pan <ljp@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
When H_SEND_CRQ command returns with H_CLOSED, it means the
server's CRQ is not ready yet. Instead of resetting immediately,
we wait for the server to launch passive init.
ibmvnic_init() and ibmvnic_reset_init() should also return the
error code from ibmvnic_send_crq_init() call.
Signed-off-by: Lijun Pan <ljp@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Instead of comparing (adapter->init_done_rc == 1), let it
be (adapter->init_done_rc == PARTIALSUCCESS).
Signed-off-by: Lijun Pan <ljp@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
At the time of do_rest, ibmvnic tries to re-initalize the tx_pools
and rx_pools to avoid re-allocating the long term buffer. However
there is a window inside do_reset that the tx_pools and
rx_pools were freed before re-initialized making it possible to deference
null pointers.
This patch fix this issue by always check the tx_pool
and rx_pool are not NULL after ibmvnic_login. If so, re-allocating
the pools. This will avoid getting into calling reset_tx/rx_pools with
NULL adapter tx_pools/rx_pools pointer. Also add null pointer check in
reset_tx_pools and reset_rx_pools to safe handle NULL pointer case.
Signed-off-by: Mingming Cao <mmc@linux.vnet.ibm.com>
Signed-off-by: Dany Madden <drt@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Currently the driver reads RX and TX subCRQ handle array directly from
a DMA-mapped buffer address when it needs to make a H_SEND_SUBCRQ
hcall. This patch stores that information in the ibmvnic_sub_crq_queue
structure instead of reading from the buffer received at login. The
overall goal of this patch is to parse relevant information from the
login response buffer and store it in the driver's private data
structures so that we don't need to read directly from the buffer and
can then free up that memory.
Signed-off-by: Cristobal Forno <cforno12@linux.ibm.com>
Reviewed-by: Jesse Brandeburg <jesse.brandeburg@intel.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
RX queue IRQ mappings are disposed in both the TX IRQ and RX IRQ
error paths. Fix this and dispose of TX IRQ mappings correctly in
case of an error.
Fixes: ea22d51a78 ("ibmvnic: simplify and improve driver probe function")
Signed-off-by: Thomas Falcon <tlfalcon@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Continue the reset path when partner adapter is not ready or H_CLOSED is
returned from reset crq. This patch allows the CRQ init to proceed to
establish a valid CRQ for traffic to flow after reset.
Signed-off-by: Dany Madden <drt@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
The VNIC driver's "login" command sequence is the final step
in the driver's initialization process with device firmware,
confirming the available device queue resources to be utilized
by the driver. Under high system load, firmware may not respond
to the request in a timely manner or may abort the request. In
such cases, the driver should reattempt the login command
sequence. In case of a device error, the number of retries
is bounded.
Signed-off-by: Thomas Falcon <tlfalcon@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Ensure that all scheduled work items have completed before continuing
with device removal and after further event scheduling has been
halted. This patch fixes a bug where a scheduled driver reset event
is processed following device removal.
Signed-off-by: Thomas Falcon <tlfalcon@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
VNIC protocol version is reported in big-endian format, but it
is not byteswapped before logging. Fix that, and remove version
comparison as only one protocol version exists at this time.
Signed-off-by: Thomas Falcon <tlfalcon@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
During MTU change, the following events may happen.
Client-driven CRQ initialization fails due to partner’s CRQ closed,
causing client to enqueue a reset task for FATAL_ERROR. Then passive
(server-driven) CRQ initialization succeeds, causing client to
release CRQ and enqueue a reset task for failover. If the passive
CRQ initialization occurs before the FATAL reset task is processed,
the FATAL error reset task would try to access a CRQ message queue
that was freed, causing an oops. The problem may be most likely to
occur during DLPAR add vNIC with a non-default MTU, because the DLPAR
process will automatically issue a change MTU request.
Fix this by not processing fatal error reset if CRQ is passively
initialized after client-driven CRQ initialization fails.
Signed-off-by: Juliet Kim <julietk@linux.vnet.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
The ibmvnic driver does not check the device state when the device
is removed. If the device is removed while a device reset is being
processed, the remove may free structures needed by the reset,
causing an oops.
Fix this by checking the device state before processing device remove.
Signed-off-by: Juliet Kim <julietk@linux.vnet.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
This conditional is missing a bang, with the intent
being to break when the retry count reaches zero.
Fixes: 476d96ca9c ("ibmvnic: Bound waits for device queries")
Suggested-by: Juliet Kim <julietk@linux.vnet.ibm.com>
Signed-off-by: Thomas Falcon <tlfalcon@linux.ibm.com>
Signed-off-by: Jakub Kicinski <jakub.kicinski@netronome.com>
Provide some serialization for device CRQ commands
and queries to ensure that the shared variable used for
storing return codes is properly synchronized.
Signed-off-by: Thomas Falcon <tlfalcon@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Create a wrapper for wait_for_completion calls with additional
driver checks to ensure that the driver does not wait on a
disabled device. In those cases or if the device does not respond
in an extended amount of time, this will allow the driver an
opportunity to recover.
Signed-off-by: Thomas Falcon <tlfalcon@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
If we receive a notification that the device has been deactivated
or removed, force a completion of all waiting threads.
Signed-off-by: Thomas Falcon <tlfalcon@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Fix multiple calls to init_completion for device completion
structures. Instead, initialize them during device probe and
reinitialize them later as needed.
Signed-off-by: Thomas Falcon <tlfalcon@linux.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Reversion of commit 11d49ce9f7
(“net/ibmvnic: Fix EOI when running in XIVE mode.”) leaves us
calling H_EOI even in XIVE mode. That will fail with H_FUNCTION
because H_EOI is not supported in that mode. That failure is
harmless. Ignore it so we can use common code for both XICS and
XIVE.
Signed-off-by: Juliet Kim <julietk@linux.vnet.ibm.com>
Signed-off-by: David S. Miller <davem@davemloft.net>