Commit Graph

5 Commits

Author SHA1 Message Date
Kishon Vijay Abraham I
2c949ce38f ARM: DRA7: clockdomain: Change the CLKTRCTRL of CM_PCIE_CLKSTCTRL to SW_WKUP
The PCIe programming sequence in TRM suggests CLKSTCTRL of PCIe should be
set to SW_WKUP. There are no issues when CLKSTCTRL is set to HW_AUTO in RC
mode. However in EP mode, the host system is not able to access the
MEMSPACE and setting the CLKSTCTRL to SW_WKUP fixes it.

Acked-by: Tony Lindgren <tony@atomide.com>
Signed-off-by: Kishon Vijay Abraham I <kishon@ti.com>
Signed-off-by: Bjorn Helgaas <bhelgaas@google.com>
2017-04-28 10:23:20 -05:00
Joel Fernandes
c2ce5fb3f3 ARM: OMAP: DRA7xx: Make L4SEC clock domain SWSUP only
Using HWSUP for l4sec clock domain is causing warnings in HWMOD code for
DRA7. Based on some observations, once the clock domain goes into an IDLE
state (because of no activity etc), the IDLEST for the module goes to '0x2'
value which means Interface IDLE condition. So far so go, however once the
MODULEMODE is set to disabled for the particular IP, the IDLEST for the
module should go to '0x3', per the HW AUTO IDLE protocol. However this is
not observed and there is no reason per the protocl for the transition to
not happen. This could potentially be a bug in the HW AUTO state-machine.

Work around for this is to use SWSUP only for the particular clockdomain.
With this all the transitions of IDLEST happen correctly and warnings
don't occur.

Signed-off-by: Joel Fernandes <joelf@ti.com>
Signed-off-by: Lokesh Vutla <lokeshvutla@ti.com>
Signed-off-by: Tero Kristo <t-kristo@ti.com>
Signed-off-by: Tony Lindgren <tony@atomide.com>
2016-11-09 15:35:46 -07:00
Keerthy
1cbabcb980 ARM: DRA7: clockdomain: Implement timer workaround for errata i874
Errata Title:
i874: TIMER5/6/7/8 interrupts not propagated

Description:
When TIMER5, TIMER6, TIMER7, or TIMER8 clocks are enabled
(CM_IPU_TIMER5/6/7/8_CLKCTRL[0:1]MODULEMODE=0x2:ENABLE) and the CD-IPU
is in HW_AUTO mode (CM_IPU_CLKSTCTRL[0:1]CLKTRCTRL=0x3:HW_AUTO) the
corresponding TIMER will continue counting, but enabled interrupts
will not be propagated to the destinations (MPU, DSP, etc) in the
SoC until the TIMER registers are accessed from the CPUs (MPU, DSP
etc.). This can result in missed timer interrupts.

Workaround:
In order for TIMER5/6/7/8 interrupts to be propagated and serviced
correctly the CD_IPU domain should be set to SW_WKUP mode
(CM_IPU_CLKSTCTRL[0:1]CLKTRCTRL=0x2:SW_WKUP).

The above workaround is achieved by switching the IPU clockdomain
flags from HWSUP_SWSUP to SWSUP only.

Signed-off-by: Keerthy <j-keerthy@ti.com>
Signed-off-by: Suman Anna <s-anna@ti.com>
Signed-off-by: Paul Walmsley <paul@pwsan.com>
2016-04-10 11:43:57 -06:00
Vignesh R
b9e23f3219 ARM: OMAP2+: DRA7: clockdomain: change l4per2_7xx_clkdm to SW_WKUP
Legacy IPs like PWMSS, present under l4per2_7xx_clkdm, cannot support
smart-idle when its clock domain is in HW_AUTO on DRA7 SoCs. Hence,
program clock domain to SW_WKUP.

Signed-off-by: Vignesh R <vigneshr@ti.com>
Acked-by: Tero Kristo <t-kristo@ti.com>
Reviewed-by: Paul Walmsley <paul@pwsan.com>
Signed-off-by: Paul Walmsley <paul@pwsan.com>
Cc: <stable@vger.kernel.org>
2015-07-15 13:57:28 -06:00
Ambresh K
11fadcfab9 ARM: OMAP: DRA7: clockdomain: Add DRA7XX data and update header
Add the data file to describe all clock domains inside the DRA7XX SoC

Signed-off-by: Ambresh K <ambresh@ti.com>
Signed-off-by: Tero Kristo <t-kristo@ti.com>
Signed-off-by: Rajendra Nayak <rnayak@ti.com>
[paul@pwsan.com: added generation notation to comments]
Signed-off-by: Paul Walmsley <paul@pwsan.com>
2013-08-23 04:28:36 -06:00