The DCB credits refill quantum _must_ be greater than half the max
packet size. This is needed to guarantee that TX DMA operations
are not attempted during a pause state. Additionally, the min IFG
must be set correctly for DCB mode. If a DMA operation is
requested unexpectedly during the pause state the HW data
store may be corrupted leading to a DMA hang. The DMA hang
requires a reset to correct. This fixes the HW configuration
to avoid this condition.
Signed-off-by: John Fastabend <john.r.fastabend@intel.com>
Tested-by: Ross Brattain <ross.b.brattain@intel.com>
Signed-off-by: Jeff Kirsher <jeffrey.t.kirsher@intel.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Following patch fixes warnings reported by `make namespacecheck`
Reported by Stephen Hemminger
CC: Stephen Hemminger <shemminger@vyatta.com>
Signed-off-by: Emil Tantilov <emil.s.tantilov@intel.com>
Tested-by: Stephen Ko <stephen.s.ko@intel.com>
Signed-off-by: Jeff Kirsher <jeffrey.t.kirsher@intel.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Remove functions that are declared, but not used in the driver.
This patch fixes warnings reported by `make namespacecheck`
Reported by Stephen Hemminger
CC: Stephen Hemminger <shemminger@vyatta.com>
Signed-off-by: Emil Tantilov <emil.s.tantilov@intel.com>
Tested-by: Stephen Ko <stephen.s.ko@intel.com>
Signed-off-by: Jeff Kirsher <jeffrey.t.kirsher@intel.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Set the DPF bit when PFC is enabled. This will discard
PFC frames so they do not get passed up the stack.
The DPF bit is set for flow control, but not priority
flow control this brings pfc inline with fc.
Signed-off-by: John Fastabend <john.r.fastabend@intel.com>
Signed-off-by: Don Skidmore <donald.c.skidmore@intel.com>
Tested-by: Ross Brattain <ross.b.brattain@intel.com>
Signed-off-by: Jeff Kirsher <jeffrey.t.kirsher@intel.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Signed-off-by: Shannon Nelson <shannon.nelson@intel.com>
Signed-off-by: Jeff Kirsher <jeffrey.t.kirsher@intel.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
When disabling the Rx and Tx data arbiters prior to configuration changes,
the arbiters were not being shut down properly. This can create a race
in the DCB hardware blocks, and potentially hang the arbiters. Also, the
Tx descriptor arbiter shouldn't be disabled when applying configuration
changes; disabling this arbiter can cause a Tx hang.
Signed-off-by: Peter P Waskiewicz Jr <peter.p.waskiewicz.jr@intel.com>
Signed-off-by: Jeff Kirsher <jeffrey.t.kirsher@intel.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Fix autoneg restart issues in flow control path which might create
endless link flickering due to known timing issues with 82599
adapters.
Signed-off-by: Mallikarjuna R Chilakala <mallikarjuna.chilakakla@intel.com>
Signed-off-by: Jeff Kirsher <jeffrey.t.kirsher@intel.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
The thresholds for the DCB priority flow control are incorrect for 82599.
This fixes the thresholds to be correct.
Signed-off-by: Peter P Waskiewicz Jr <peter.p.waskiewicz.jr@intel.com>
Signed-off-by: Jeff Kirsher <jeffrey.t.kirsher@intel.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
When changing DCB parameters, ixgbe needs to have the MAC reset. The way
the flow control code is setup today, PFC will be disabled on a reset.
This patch adds a new flow control type for PFC, and then has the netlink
layer take care of toggling which type of flow control to enable.
Signed-off-by: Peter P Waskiewicz Jr <peter.p.waskiewicz.jr@intel.com>
Signed-off-by: Jeff Kirsher <jeffrey.t.kirsher@intel.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
'pap' is never used in ixgbe_dcb_hw_config_82599()
and 'eec' in ixgbe_acquire_eeptom() is only used when
status == 0 but GCC has some trouble seeing that.
Signed-off-by: David S. Miller <davem@davemloft.net>
This patch adds the DCB (Data Center Bridging) support for 82599 hardware.
This is similar to how the 82598 DCB code works.
This patch also removes the BCN (Backwards Congestion Notification) netlink
configuration code from the driver. BCN was a pre-standard congestion
notification framework, and was not what the IEEE body decided upon for
standard congestion management. QCN (802.1Qau), Quantized Congestion
Notification is the accepted standard, which is not supported by 82599,
hence we remove the support altogether.
Signed-off-by: Peter P Waskiewicz Jr <peter.p.waskiewicz.jr@intel.com>
Signed-off-by: Jeff Kirsher <jeffrey.t.kirsher@intel.com>
Signed-off-by: David S. Miller <davem@davemloft.net>