Move ad7780 ADC driver out of staging and into the mainline.
The ad7780 is a sigma-delta analog to digital converter. This driver provides
reading voltage values and status bits from both the ad778x and ad717x series.
Its interface also allows writing on the FILTER and GAIN GPIO pins on the
ad778x.
Signed-off-by: Renato Lui Geh <renatogeh@gmail.com>
Signed-off-by: Giuliano Belinassi <giuliano.belinassi@usp.br>
Co-developed-by: Giuliano Belinassi <giuliano.belinassi@usp.br>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
This patch adds a new copyright holder to the ad7780 driver.
Signed-off-by: Renato Lui Geh <renatogeh@gmail.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Add SPDX identifier (GPL-2.0) to the AD7780 driver.
Signed-off-by: Renato Lui Geh <renatogeh@gmail.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
To maintain consistency between ad7780_probe and ad7780_remove orders,
regulator initialization has been moved to after GPIO initializations.
Signed-off-by: Renato Lui Geh <renatogeh@gmail.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
The ad7780 supports both the ad778x and ad717x families. Each chip has
a corresponding ID. This patch provides a mask for extracting ID values
from the status bits and also macros for the correct values for the
ad7170, ad7171, ad7780 and ad7781.
Signed-off-by: Renato Lui Geh <renatogeh@gmail.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
The AD7780 driver contains status pattern bits designed for checking
whether serial transfers have been correctly performed. Pattern macros
were previously generated through bit fields. This patch sets good
pattern values directly and masks through GENMASK.
Signed-off-by: Renato Lui Geh <renatogeh@gmail.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
This patch adds the new feature of reading the filter odr value for
ad778x chips. This value is stored in the chip's state struct whenever a
read or write call is performed on the chip's driver.
This feature requires sharing SAMP_FREQ. Since the ad717x does not have
a filter option, the driver only shares the relevant info mask for the
ad778x family.
Signed-off-by: Renato Lui Geh <renatogeh@gmail.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
This patch adds a new functionality of reading gain values from the
ad778x chips. This value is stored in the chip's state struct and is
updated whenever a read or write call is performed on the driver.
Signed-off-by: Renato Lui Geh <renatogeh@gmail.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
This patch simply adds a missing switch default case in read_raw.
Signed-off-by: Renato Lui Geh <renatogeh@gmail.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Previously, the AD7780 driver only supported gpio for the 'powerdown'
pin. This commit adds suppport for the 'gain' and 'filter' pin.
Signed-off-by: Renato Lui Geh <renatogeh@gmail.com>
Signed-off-by: Giuliano Belinassi <giuliano.belinassi@usp.br>
Co-developed-by: Giuliano Belinassi <giuliano.belinassi@usp.br>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
This patch will remove platform data members and replace them with device
tree properties. These properties will be subject to further modifications
and probably replaced with other functionalities at some point in time.
Signed-off-by: Mircea Caprioru <mircea.caprioru@analog.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
This patch removes the goto out statement and uninformative
print message. This improves readability.
Signed-off-by: Mircea Caprioru <mircea.caprioru@analog.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
This patch replaces the platform data clock select member with DT clock
binding. Through the DT the external clock binding is specified. If this is
not provided then the device will use the internal clock source.
With the external clock binding there is the option to use a clock or a
crystal as the clock source. When an external crystal is used it is
connected to MCLK1 and MCLK2 pins. If the external clock is used only MCLK2
pin will be connected.
Signed-off-by: Mircea Caprioru <mircea.caprioru@analog.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
This patch fixes the odd indentation inside function ad7192_calibrate_all.
Signed-off-by: Mircea Caprioru <mircea.caprioru@analog.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
The clock frequency is loaded from device-tree using clock framework
instead of statically value. The change allow configuration of
the device via device-trees and better initialization sequence.
This is part of broader effort to add device-tree support to this driver
and take it out from staging.
Signed-off-by: Beniamin Bia <beniamin.bia@analog.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
The values from platform data were replaced by statically values.
This was just a intermediate step of taking this driver out of staging and
load data from device tree.
Signed-off-by: Beniamin Bia <beniamin.bia@analog.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
The AD7153 part has been obsoleted for some time. The AD7152 part will be
obsolete in the coming future.
Moving it out of staging doesn't make sense anymore. Which makes the driver
enter a limbo state.
This patch removes the driver completely, so that no effort is placed on
it, allowing people to focus on other parts that will still be around.
Signed-off-by: Alexandru Ardelean <alexandru.ardelean@analog.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
The lsb calculation is not masking the correct bits from the user input.
Subtract 1 from (1 << offset) to correctly set up the mask to be applied
to user input.
The lsb register stores its value starting at the bit 7 position.
adt7316_store_DAC() currently assumes the value is at the other end of the
register. Shift the lsb value before storing it in a new variable lsb_reg,
and write this variable to the lsb register.
Fixes: 35f6b6b86e ("staging: iio: new ADT7316/7/8 and ADT7516/7/9 driver")
Signed-off-by: Jeremy Fertic <jeremyfertic@gmail.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
The calculation of the current dac value is using the wrong bits of the
dac lsb register. Create two macros to shift the lsb register value into
lsb position, depending on whether the dac is 10 or 12 bit. Initialize
data to 0 so, with an 8 bit dac, the msb register value can be bitwise
ORed with data.
Fixes: 35f6b6b86e ("staging: iio: new ADT7316/7/8 and ADT7516/7/9 driver")
Signed-off-by: Jeremy Fertic <jeremyfertic@gmail.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
The adt7316/7 and adt7516/7 have the option to output voltage proportional
to temperature on dac a and/or dac b. The default dac resolution in this
mode is 8 bits with the dac high resolution option enabling 10 bits. None
of these settings affect dacs c and d. Remove the "1 (12 bits)" output from
the show function since that is not an option for this mode. Return
"1 (10 bits)" if the device is one of the above mentioned chips and the dac
high resolution mode is enabled.
In the store function, the driver currently allows the user to write to the
ADT7316_DA_HIGH_RESOLUTION bit regardless of the device in use. Add a check
to return an error in the case of an adt7318 or adt7519. Remove the else
statement that clears the ADT7316_DA_HIGH_RESOLUTION bit. Instead, clear it
before conditionally enabling it, depending on user input. This matches the
typical pattern in the driver when an attribute is a boolean.
Fixes: 35f6b6b86e ("staging: iio: new ADT7316/7/8 and ADT7516/7/9 driver")
Signed-off-by: Jeremy Fertic <jeremyfertic@gmail.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
The value of dac_bits is used in adt7316_show_DAC() and adt7316_store_DAC(),
and it should be either 8, 10, or 12 bits depending on the device in use. The
driver currently only assigns a value to dac_bits in
adt7316_store_da_high_resolution(). The purpose of the dac high resolution
option is not to change dac resolution for normal operation. Instead, it
is specific to an optional feature where one or two of the four dacs can
be set to output voltage proportional to temperature. If the user chooses
to set dac a and/or dac b to output voltage proportional to temperature,
the da_high_resolution attribute can optionally be enabled to use 10 bit
resolution rather than the default 8 bits. This is only available on the
10 and 12 bit dac devices. If the user attempts to read or write dacs a
or b under these settings, the driver's current behaviour is to return an
error. Dacs c and d continue to operate normally under these conditions.
With the above in mind, remove the dac_bits assignments from this function
since the value of dac_bits as used in the driver is not dependent on this
dac high resolution option.
Since the dac_bits assignments discussed above are currently the only ones
in this driver, the default value of dac_bits is 0. This results in incorrect
calculations when the dacs are read or written in adt7316_show_DAC() and
adt7316_store_DAC(). To correct this, assign a value to dac_bits in
adt7316_probe() to ensure correct operation as soon as the device is
registered and available to userspace.
Fixes: 35f6b6b86e ("staging: iio: new ADT7316/7/8 and ADT7516/7/9 driver")
Signed-off-by: Jeremy Fertic <jeremyfertic@gmail.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Move ad7606 ADC driver out of staging and into the mainline.
Signed-off-by: Stefan Popa <stefan.popa@analog.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
* Placed includes in alphabetical order
* Added brackets around num and mask through out for AD760X_CHANNEL
* Used single line comments where needed
* Removed extra lines and spaces
Signed-off-by: Stefan Popa <stefan.popa@analog.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
This patch replaces the use of a polling ring buffer with a threaded
interrupt.
Enabling the buffer sets the CONVST signal to high. When the rising edge
of the CONVST is applied, BUSY signal goes logic high and transitions low
at the end of the entire conversion process. The falling edge of the BUSY
signal triggers the interrupt.
ad7606_trigger_handler() is used as bottom half of the poll function.
It reads data from the device and stores it in the internal buffer.
Signed-off-by: Stefan Popa <stefan.popa@analog.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
This patch replaces the license text at the top of ad7606 driver files
and instead adds SPDX GPL-2.0 license identifier.
Signed-off-by: Stefan Popa <stefan.popa@analog.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
There is no point in having three menu entries that can be selected
individually. Instead, the SPI and parallel interfaces should select
AD7606.
Signed-off-by: Stefan Popa <stefan.popa@analog.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
The driver does not have a struct of_device_id table, but supported
devices are registered via Device Trees. This patch adds and OF device
ID table.
Signed-off-by: Stefan Popa <stefan.popa@analog.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
The 'adi' vendor prefix needs to be added to conversion-start, range,
first-data and oversampling-ratio properties.
Signed-off-by: Stefan Popa <stefan.popa@analog.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
When looking for the available scale or oversampling ratio, it is better
to use the find_closest() macro. This simplifies the code and also does
not require an exact value to be entered from the user space.
Signed-off-by: Stefan Popa <stefan.popa@analog.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Switch to devm version of request_irq, iio_triggered_buffer_setup,
iio_device_register. To avoid potential ordering issues in probe,
devm_add_action_or_reset() is used for the regulator_disable(). This
simplifies the code and decreases the chance of bugs.
Signed-off-by: Stefan Popa <stefan.popa@analog.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
This patch replaces the use of wait_event_interruptible() with
wait_for_completion_timeout() when reading the result of a single
conversion. In this way, if the interrupt never occurs, the program will
not remain blocked.
Signed-off-by: Stefan Popa <stefan.popa@analog.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Initialization is unnecessary when the variable is written before it is
read. There were some occasions in which the driver would initialize `ret'
during declaration without need.
Signed-off-by: Hardik Singh Rathore <hardiksingh.k@gmail.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
The ad7280_attr_init function has been split into more specific
functions to increase the code readability.
Signed-off-by: Slawomir Stepien <sst@poczta.fm>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
The ad7280_channel_init function has been split into more specific
functions to increase the code readability.
The setting of channel's scan_type.shift to 0, has been removed, since
it is the default value.
Signed-off-by: Slawomir Stepien <sst@poczta.fm>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Add the option to specify the external clock (MCLK) using the clock
framework.
Also remove the old platform data structure.
Signed-off-by: Marcelo Schmitt <marcelo.schmitt1@gmail.com>
Signed-off-by: Gabriel Capella <gabriel@capella.pro>
Co-developed-by: Gabriel Capella <gabriel@capella.pro>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Set a single voltage regulator for all voltage references.
Remove voltage reference value from default platafrom data struct.
Signed-off-by: Marcelo Schmitt <marcelo.schmitt1@gmail.com>
Signed-off-by: Gabriel Capella <gabriel@capella.pro>
Co-developed-by: Gabriel Capella <gabriel@capella.pro>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
ADT7316 driver no more uses platform data and hence use device tree
data instead of platform data for assigning irq_type field and
implement this in adt7316_irq_setup function.
Switch case figures out the type of irq and if it's the default case
then assign the default value to the irq_type i.e.
irq_type = IRQF_TRIGGER_LOW
Move devm_request_threaded_irq() and assignment of chip->config1
into the adt7316_setup_irq() to unclutter the code in probe function.
Signed-off-by: Shreeya Patel <shreeya.patel23498@gmail.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Initialization is unnecessary when the variable is written before it is
read. There were some occasions in which the driver would initialize `ret'
during declaration without need.
Purely a cosmetic change with no functional impact.
Signed-off-by: Hardik Singh Rathore <hardiksingh.k@gmail.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Based on the output of adt7316_show_all_DAC_update_modes() and
adt7316_show_DAC_update_mode(), adt7316_store_DAC_update_mode() should
expect the user to enter an integer input from 0 to 3. The user input is
currently expected to account for the actual bit positions in the register.
For example, choosing option 3 would require a write of 0x30 (actually 48
since it expects base 10). To address this inconsistency, create a shift
macro to be used in the valid input check as well as the calculation for
the register write.
Signed-off-by: Jeremy Fertic <jeremyfertic@gmail.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
The option to allow the external vref to bypass the reference buffer is
only available for adt7316/7/8. Remove the attributes for adt751x as
well as the chip->id checks from the show and store functions.
Signed-off-by: Jeremy Fertic <jeremyfertic@gmail.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
With adt7516/7/9, internal vref is available for dacs a and b, dacs c and
d, or all dacs. The driver doesn't currently support internal vref for all
dacs. Change the else if to an if so both bits are checked rather than
just one or the other.
Signed-off-by: Jeremy Fertic <jeremyfertic@gmail.com>
Fixes: 35f6b6b86e ("staging: iio: new ADT7316/7/8 and ADT7516/7/9 driver")
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
The dac internal vref settings are part of the ldac config register rather
than the dac config register. Change the variable being used so the read
returns the correct result.
Whilst a fix, it is for a driver in heavy churn so do not backport
to stable without taking considerable care and testing.
Signed-off-by: Jeremy Fertic <jeremyfertic@gmail.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
ADT7316_DA_EN_VIA_DAC_LDCA is set when the dac and ldac registers are being
used to update the dacs instead of the ldac pin. ADT7516_SEL_AIN3 is an adc
input that shares the ldac pin. Only set these bits if an ldac pin is not
being used.
This could be backported to stable, but note there are various
other bugs that probably make that a waste of time.
Signed-off-by: Jeremy Fertic <jeremyfertic@gmail.com>
Fixes: 35f6b6b86e ("staging: iio: new ADT7316/7/8 and ADT7516/7/9 driver")
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Change two register addresses and one bit definition to match the
datasheet.
Note that there are many issues in this driver so I would
not suggest backporting these fixes to stable trees.
Signed-off-by: Jeremy Fertic <jeremyfertic@gmail.com>
Fixes: 35f6b6b86e ("staging: iio: new ADT7316/7/8 and ADT7516/7/9 driver")
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
This reverts commit 00426e9978.
i2c_smbus_read_byte() returns 0 when a byte with the value 0 is read from
the device. This is a valid read so revert the check for 0.
Signed-off-by: Jeremy Fertic <jeremyfertic@gmail.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
The ret returned from ad7280_chain_setup() is needed to initialize the
slave_num. Don't overwrite it with call to devm_add_action_or_reset().
Fixes: cc9c58ef6e ("staging: iio: adc: ad7280a: use devm_* APIs")
Signed-off-by: Slawomir Stepien <sst@poczta.fm>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
devm_kasprintf() may return NULL on failure of internal allocation thus
the assignments to attr.name are not safe if not checked. On error
ad7280_attr_init() returns a negative return so -ENOMEM should be
OK here (passed on as return value of the probe function). To make the
error case more readable a temporary iio_attr is introduced and the code
refactored.
Signed-off-by: Nicholas Mc Guire <hofrat@osadl.org>
Fixes: 2051f25d2a ("iio: adc: New driver for AD7280A Lithium Ion Battery Monitoring System2")
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Move ad2s90 resolver driver out of staging to the main tree.
Signed-off-by: Matheus Tavares <matheus.bernardino@usp.br>
Signed-off-by: Victor Colombo <victorcolombo@gmail.com>
Acked-by: Alexandru Ardelean <alexandru.ardelean@analog.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>