To skip registering regulator if no platform initialization data,
we should check reg_data rather than ri->desc.name.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Acked-by: Guennadi Liakhovetski <g.liakhovetski@gmx.de>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Below equation means the "voltage" is the "smallest" voltage within specific
range.
ret = DIV_ROUND_UP(min - bottom) / step;
voltage = ret * step + bottom;
If we do try 1 down when (voltage > max), new voltage is then less than min
voltage. Which means the new voltage is not in the requested voltage range.
This patch also includes below cleanups:
- Use DIV_ROUND_UP
- rename variable 'ret' to 'sel' for better readability because as3711_sel_check
returns the selector.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Acked-by: Guennadi Liakhovetski <g.liakhovetski@gmx.de>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Below cases are supposed to be valid:
min_uV == max_uV == info->max_uV
min_uV == max_uV == rdev->desc->min_uV
Don't return -EINVAL for above cases.
This patch also includes below cleanups:
- Use rdev_get_drvdata(rdev) instead of rdev->reg_data.
- Remove unnecessary WARN_ON, it looks pointless.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Acked-by: Guennadi Liakhovetski <g.liakhovetski@gmx.de>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
This driver supports the 4 DCDC and 8 LDO regulators on the AS3711 PMIC.
Signed-off-by: Guennadi Liakhovetski <g.liakhovetski@gmx.de>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>