This patch addresses below issues:
1) Few endianness bug fixes.
2) Break the iteration after (MAX_LOGICAL_DRIVES_EXT - 1)),
instead of MAX_LOGICAL_DRIVES_EXT.
3) Optimization in MFI INIT frame before firing.
4) MFI IO frame should be 256bytes aligned. Code is optimized to reduce
the size of frame for fusion adapters and make the MFI frame size
calculation a bit transparent and readable.
Cc: <stable@vger.kernel.org>
Signed-off-by: Kashyap Desai <kashyap.desai@avagotech.com>
Signed-off-by: Sumit Saxena <sumit.saxena@avagotech.com>
Signed-off-by: Chaitra Basappa <chaitra.basappa@avagotech.com>
Reviewed-by: Martin K. Petersen <martin.petersen@oracle.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Update MAINTAINERS list and copyright information for megaraid_sas driver.
Signed-off-by: Sumit Saxena <sumit.saxena@avagotech.com>
Reviewed-by: Tomas Henzl <thenzl@redhat.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Resending the patch. Addressed the review comments from Tomas Henzl.
Current driver does fast path read load balancing between arm and mirror disk
for two Drive Raid-1 configuration only.
Now, Driver support fast path read load balancing for all (any number of disk) Raid-1 configuration.
Signed-off-by: Sumit Saxena <sumit.saxena@avagotech.com>
Signed-off-by: Kashyap Desai <kashyap.desai@avagotech.com>
Reviewed-by: Tomas Henzl <thenzl@redhat.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Resending the patch. Addressed the review comments from Tomas Henzl.
reserved1 field(part of union) of Raid map struct was not required so it is removed.
Current MegaRAID firmware and hence the driver only supported 64VDs.
E.g: If the user wants to create more than 64VD on a controller,
it is not possible on current firmware/driver.
New feature and requirement to support upto 256VD, firmware/driver/apps need changes.
In addition to that there must be a backward compatibility of the new driver with the
older firmware and vice versa.
RAID map is the interface between Driver and FW to fetch all required
fields(attributes) for each Virtual Drives.
In the earlier design driver was using the FW copy of RAID map where as
in the new design the Driver will keep the RAID map copy of its own; on which
it will operate for any raid map access in fast path.
Local driver raid map copy will provide ease of access through out the code
and provide generic interface for future FW raid map changes.
For the backward compatibility driver will notify FW that it supports 256VD
to the FW in driver capability field.
Based on the controller properly returned by the FW, the Driver will know
whether it supports 256VD or not and will copy the RAID map accordingly.
At any given time, driver will always have old or new Raid map.
So with this changes, driver can also work in host lock less mode. Please
see next patch which enable host lock less mode for megaraid_sas driver.
Signed-off-by: Sumit Saxena <sumit.saxena@avagotech.com>
Signed-off-by: Kashyap Desai <kashyap.desai@avagotech.com>
Reviewed-by: Tomas Henzl <thenzl@redhat.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
The following patch for megaraid_sas loads the correct raid context timeout
value for multpathing and clustering.
Signed-off-by: Adam Radford <aradford@gmail.com>
Signed-off-by: James Bottomley <JBottomley@Parallels.com>
This patch will add big endian architecture support to megaraid_sas
driver. The support added is for LSI MegaRAID all generation controllers-
(3Gb/s, 6Gb/s and 12 Gb/s controllers).
We have done basic sanity test @ppc64 arch and @x86_64. Additional
testing/observations are welcome.
[jejb: fix up rejections]
Signed-off-by: Kashyap Desai <kashyap.desai@lsi.com>
Signed-off-by: Sumit Saxena <sumit.saxena@lsi.com>
Signed-off-by: James Bottomley <JBottomley@Parallels.com>
On 64 bit then -1UL and -1U are not equal, so these conditions don't
work as intended and it breaks error handling.
Signed-off-by: Dan Carpenter <dan.carpenter@oracle.com>
Acked-by: Sumit Saxena <sumit.saxena@lsi.com>
Signed-off-by: James Bottomley <JBottomley@Parallels.com>
MegaRAID older Firmware does not support uneven span configuration for PRL11.
E.g User wants to create 34 Driver PRL11 config, it was not possible using old
firmware, since it was not supported configuration in old firmware
Old Firmware expect even number of Drives in each span and same number of
physical drives at each span. Considering above design, 17 Drives at Span-0
and 17 drives at span-1 was not possible.
Now, using this new feature Firmware and Driver both required changes. New
Firmware can allow user to create 16 Drives at span-0 and 18 Drives at
span-1. This will allow user to create 34 Drives Uneven span PRL11.
RAID map is interface between Driver and FW to fetch all required
fields(attributes) for each Virtual Drives. Since legacy RAID map consider
Even Span design, there was no place to keep Uneven span information in
existing Raid map. Because of this limitation, for Uneven span VD, driver can
not use RAID map.
This patch address the changes required in Driver to support Uneven span PRL11
support.
1. Driver will find if Firmware has UnevenSpanSupport or not by reading
Controller Info.
2. If Firmware has UnvenSpan PRL11 support, then Driver will inform about its
capability of handling UnevenSpan PRL11 to the firmware.
3. Driver will update its copy of span info on each time Raid map update is
called.
4. Follow different IO path if it is Uneven Span. (For Uneven Span, Driver
uses Span Set info to find relavent fields for that particular Virtual
Disk)
More verbose prints will be available by setting "SPAN_DEBUG" to 1 at
compilation time.
Signed-off-by: Sumit Saxena <sumit.saxena@lsi.com>
Signed-off-by: Kashyap Desai <kashyap.desai@lsi.com>
Signed-off-by: James Bottomley <JBottomley@Parallels.com>
The following patch for megaraid_sas fixes the fastpath code decision
logic to use fpRead/WriteCapable, fpRead/WriteAcrossStripe flags
instead of the old logic. This fixes a bug where fastpath writes
could be sent to a read only LD.
Signed-off-by: Adam Radford <aradford@gmail.com>
Signed-off-by: James Bottomley <JBottomley@Parallels.com>
The following patch for megaraid_sas fixes the reglockFlags field for
degraded raid5/6 for MR9360/9380, which will result in a performance
improvement.
Signed-off-by: Adam Radford <aradford@gmail.com>
Signed-off-by: James Bottomley <JBottomley@Parallels.com>
These were missed the last time I cleaned this up
globally, because of code moving around or new code
getting merged.
Signed-off-by: Arnd Bergmann <arnd@arndb.de>
This patch adds MegaRAID 9265/9285 (Device id 0x5b) specific code
Signed-off-by: Adam Radford <aradford@gmail.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>